Experimental investigation of gravity-assisted wickless heat pipes (thermosyphons) at low heat inputs for solar application

IF 0.8 Q4 THERMODYNAMICS Archives of Thermodynamics Pub Date : 2023-07-20 DOI:10.24425/ATHER.2020.133632
H. N. S. Al-Joboory
{"title":"Experimental investigation of gravity-assisted wickless heat pipes (thermosyphons) at low heat inputs for solar application","authors":"H. N. S. Al-Joboory","doi":"10.24425/ATHER.2020.133632","DOIUrl":null,"url":null,"abstract":"The performance of ten wickless heat pipes without adiabatic sections is investigated experimentally at low heat inputs 120 to 2000 W/m 2 for use in solar water heaters. Three heat pipe diameter groups were tested, namely 16, 22, and 28.5 mm. Each group had evaporator lengths of 1150, 1300, and 1550 mm, respectively, with an extra evaporator length of 1800 mm added to the second group. The condenser section length of all heat pipes was 200 mm. Ethanol, methanol, and acetone were utilized as working fluids, at inventory of 25%, 50%, 70%, and 90% by evaporator volume respectively. The 22 mm diameter pipes were tested at inclination angles 30 ◦ , 45 ◦ , and 60 ◦ . Other diameter groups were tested at 45 ◦ only. Experiments revealed increased surface temperatures and heat transfer coefficients with increased pipe diameter and evaporator length, and that increased working fluid inventory caused pronounced reduction in evaporator surface temperature accompanied by improved heat transfer coefficient to reach maximum values at 50% inventory for the selected fluids. Violent noisy shocks were observed with 70% and 90% inventories with the tested heat pipes and the selected working fluids with heat flux inputs from 320–1900 W/m 2 . These shocks significantly affected the heat pipes heat transfer capability and operation stability. Experiments revealed a 45 ◦ and 50% optimum inclination angle of fill charge ratio respectively, and that wickless heat pipes can be satisfactorily used in solar applications. The effect of evaporator length and heat pipe diameter on the performance was included in data correlations.","PeriodicalId":45257,"journal":{"name":"Archives of Thermodynamics","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2023-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Thermodynamics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/ATHER.2020.133632","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"THERMODYNAMICS","Score":null,"Total":0}
引用次数: 2

Abstract

The performance of ten wickless heat pipes without adiabatic sections is investigated experimentally at low heat inputs 120 to 2000 W/m 2 for use in solar water heaters. Three heat pipe diameter groups were tested, namely 16, 22, and 28.5 mm. Each group had evaporator lengths of 1150, 1300, and 1550 mm, respectively, with an extra evaporator length of 1800 mm added to the second group. The condenser section length of all heat pipes was 200 mm. Ethanol, methanol, and acetone were utilized as working fluids, at inventory of 25%, 50%, 70%, and 90% by evaporator volume respectively. The 22 mm diameter pipes were tested at inclination angles 30 ◦ , 45 ◦ , and 60 ◦ . Other diameter groups were tested at 45 ◦ only. Experiments revealed increased surface temperatures and heat transfer coefficients with increased pipe diameter and evaporator length, and that increased working fluid inventory caused pronounced reduction in evaporator surface temperature accompanied by improved heat transfer coefficient to reach maximum values at 50% inventory for the selected fluids. Violent noisy shocks were observed with 70% and 90% inventories with the tested heat pipes and the selected working fluids with heat flux inputs from 320–1900 W/m 2 . These shocks significantly affected the heat pipes heat transfer capability and operation stability. Experiments revealed a 45 ◦ and 50% optimum inclination angle of fill charge ratio respectively, and that wickless heat pipes can be satisfactorily used in solar applications. The effect of evaporator length and heat pipe diameter on the performance was included in data correlations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于太阳能应用的重力辅助无芯热管(热虹吸管)在低热输入下的实验研究
实验研究了太阳能热水器用10根无绝热段的无芯热管在120~2000W/m2低热输入下的性能。测试了三组热管直径,即16、22和28.5 mm。每组的蒸发器长度分别为1150、1300和1550 mm,第二组增加了1800 mm的额外蒸发器长度。所有热管的冷凝器段长度均为200mm。使用乙醇、甲醇和丙酮作为工作流体,其库存量分别为蒸发器体积的25%、50%、70%和90%。直径为22 mm的管道在倾斜角度30下进行测试◦ , 45◦ , 和60◦ . 其他直径组在45◦ 只有实验表明,随着管道直径和蒸发器长度的增加,表面温度和传热系数会增加,工作流体存量的增加会导致蒸发器表面温度显著降低,同时传热系数也会提高,在选定流体存量为50%时达到最大值。在测试的热管和选定的热流量输入为320–1900 W/m2的工作流体的70%和90%的库存情况下,观察到剧烈的噪声冲击。这些冲击显著影响了热管的传热能力和运行稳定性。实验显示◦ 和50%的最佳倾角,无芯热管可以令人满意地用于太阳能应用。蒸发器长度和热管直径对性能的影响包含在数据相关性中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Archives of Thermodynamics
Archives of Thermodynamics THERMODYNAMICS-
CiteScore
1.80
自引率
22.20%
发文量
0
期刊介绍: The aim of the Archives of Thermodynamics is to disseminate knowledge between scientists and engineers interested in thermodynamics and heat transfer and to provide a forum for original research conducted in Central and Eastern Europe, as well as all over the world. The journal encompass all aspect of the field, ranging from classical thermodynamics, through conduction heat transfer to thermodynamic aspects of multiphase flow. Both theoretical and applied contributions are welcome. Only original papers written in English are consider for publication.
期刊最新文献
Use of reinforced ice as alternative building material in cold regions: an overview Alternative method of making electrical connections in the 1st and 3rd generation modules as an effective way to improve module efficiency and reduce production costs Thermodynamic analysis of hybrid ceramic bearings with metal inner rings Geometrical and optical analysis of small-sized parabolic trough collector using ray tracing tool SolTrace Modular heat storage in waste heat recovery installations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1