Removal of Metal Ions via Adsorption Using Carbon Magnetic Nanocomposites: Optimization through Response Surface Methodology, Kinetic and Thermodynamic Studies

IF 2.6 4区 化学 Q2 CHEMISTRY, INORGANIC & NUCLEAR Magnetochemistry Pub Date : 2023-06-24 DOI:10.3390/magnetochemistry9070163
S. Muntean, L. Halip, M. Nistor, C. Păcurariu
{"title":"Removal of Metal Ions via Adsorption Using Carbon Magnetic Nanocomposites: Optimization through Response Surface Methodology, Kinetic and Thermodynamic Studies","authors":"S. Muntean, L. Halip, M. Nistor, C. Păcurariu","doi":"10.3390/magnetochemistry9070163","DOIUrl":null,"url":null,"abstract":"The toxicity of metal ions on ecosystems has led to increasing amounts of research on their removal from wastewater. This paper presents the efficient application of a carbon magnetic nanocomposite as an adsorbent for the elimination of metal ions (copper, lead and zinc) from aqueous solutions. A Box–Behnken factorial design combined with the response surface methodology was conducted to investigate the effect and interactions of three variables on the pollutant removal process. Highly significant (p < 0.001) polynomial models were developed for each metal ion: the correlation coefficient was 0.99 for Cu(II) and Pb(II), and 0.96 for Zn(II) ion removal. The experimental data were in agreement and close to the theoretical results, which supports the applicability of the method. Working at the natural pH of the solutions, with a quantity of carbon magnetic nanocomposite of 1 g/L and a metal ions’ concentration of 10 mg/L, for 240 min, removal efficiencies greater than 75% were obtained. The kinetic study indicated that a combination of kinetic models pseudo-second order and intraparticle diffusion were applied appropriately for copper, lead and zinc ion adsorption on carbon magnetic nanocomposite. The maximum adsorption capacities determined from the Langmuir isotherm model were 81.36, 83.54 and 57.11 mg/g for copper, lead and zinc ions. The average removal efficiency for five adsorption–desorption cycles was 82.21% for Cu(II), 84.50% for Pb(II) and 72.68% for Zn(II). The high adsorption capacities of metal ions, in a short time, as well as the easy separation of the nanocomposite from the solution, support the applicability of the magnetic carbon nanocomposite for wastewater treatment.","PeriodicalId":18194,"journal":{"name":"Magnetochemistry","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2023-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetochemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3390/magnetochemistry9070163","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 1

Abstract

The toxicity of metal ions on ecosystems has led to increasing amounts of research on their removal from wastewater. This paper presents the efficient application of a carbon magnetic nanocomposite as an adsorbent for the elimination of metal ions (copper, lead and zinc) from aqueous solutions. A Box–Behnken factorial design combined with the response surface methodology was conducted to investigate the effect and interactions of three variables on the pollutant removal process. Highly significant (p < 0.001) polynomial models were developed for each metal ion: the correlation coefficient was 0.99 for Cu(II) and Pb(II), and 0.96 for Zn(II) ion removal. The experimental data were in agreement and close to the theoretical results, which supports the applicability of the method. Working at the natural pH of the solutions, with a quantity of carbon magnetic nanocomposite of 1 g/L and a metal ions’ concentration of 10 mg/L, for 240 min, removal efficiencies greater than 75% were obtained. The kinetic study indicated that a combination of kinetic models pseudo-second order and intraparticle diffusion were applied appropriately for copper, lead and zinc ion adsorption on carbon magnetic nanocomposite. The maximum adsorption capacities determined from the Langmuir isotherm model were 81.36, 83.54 and 57.11 mg/g for copper, lead and zinc ions. The average removal efficiency for five adsorption–desorption cycles was 82.21% for Cu(II), 84.50% for Pb(II) and 72.68% for Zn(II). The high adsorption capacities of metal ions, in a short time, as well as the easy separation of the nanocomposite from the solution, support the applicability of the magnetic carbon nanocomposite for wastewater treatment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
碳磁性纳米复合材料吸附去除金属离子:响应面法优化、动力学和热力学研究
金属离子对生态系统的毒性导致了对其从废水中去除的研究越来越多。本文介绍了一种碳磁性纳米复合材料作为吸附剂的有效应用,用于去除水溶液中的金属离子(铜、铅和锌)。采用Box-Behnken析因设计结合响应面法研究了三个变量对污染物去除过程的影响和相互作用。对每种金属离子建立了高度显著(p < 0.001)的多项式模型:Cu(II)和Pb(II)的相关系数为0.99,Zn(II)离子去除的相关系数为0.96。实验数据与理论结果吻合较好,证明了该方法的适用性。在自然pH下,碳磁性纳米复合材料用量为1 g/L,金属离子浓度为10 mg/L,作用240 min,去除率大于75%。动力学研究表明,碳磁性纳米复合材料对铜、铅、锌离子的吸附适宜采用准二级和颗粒内扩散相结合的动力学模型。Langmuir等温线模型测定的铜、铅和锌离子的最大吸附量分别为81.36、83.54和57.11 mg/g。5个吸附-解吸循环对Cu(II)、Pb(II)和Zn(II)的平均去除率分别为82.21%、84.50%和72.68%。磁性碳纳米复合材料在短时间内对金属离子的高吸附能力,以及易于从溶液中分离,支持了磁性碳纳米复合材料在废水处理中的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Magnetochemistry
Magnetochemistry Chemistry-Chemistry (miscellaneous)
CiteScore
3.90
自引率
11.10%
发文量
145
审稿时长
11 weeks
期刊介绍: Magnetochemistry (ISSN 2312-7481) is a unique international, scientific open access journal on molecular magnetism, the relationship between chemical structure and magnetism and magnetic materials. Magnetochemistry publishes research articles, short communications and reviews. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. Therefore, there is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced.
期刊最新文献
Preparation and Optimization of the Adsorbent for Phosphorus Removal Using the Response Surface Method The Effect of Magnetically Induced Local Structure and Volume Fraction on the Electromagnetic Properties of Elastomer Samples with Ferrofluid Droplet Inserts Correction: Li et al. Dry Friction Performances of MoNx Coatings Deposited by High–Power Pulsed Magnetron Sputtering. Magnetochemistry 2023, 9, 60 The Influence of Viscosity on Heat Dissipation under Conditions of the High-Frequency Oscillating Magnetic Field Functional Molecular Materials Insights
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1