Concordance and consistency in the evaluation of diagnostic images of periapical tissue in endodontics

Pub Date : 2021-11-15 DOI:10.21676/2389783x.4374
C. García-Guerrero, Ángela V. Caicedo-Rosero, Cindy E. Delgado-Rodríguez, Sara Quijano-Guauque, M. Rodríguez-Godoy, Hannia Camargo-Huertas
{"title":"Concordance and consistency in the evaluation of diagnostic images of periapical tissue in endodontics","authors":"C. García-Guerrero, Ángela V. Caicedo-Rosero, Cindy E. Delgado-Rodríguez, Sara Quijano-Guauque, M. Rodríguez-Godoy, Hannia Camargo-Huertas","doi":"10.21676/2389783x.4374","DOIUrl":null,"url":null,"abstract":"To estimate the degree of concordance and consistency in the radiographic and tomographic evaluation of the periapical area. A study of diagnostic tests was designed. Three blind evaluators analyzed radiographic images, which were selected at two different points in time. An oral radiologist and an endodontist determined the second observation moment. The degree of similarity and variability, concordance and consistency for each radiograph was set at 95% confidence. A Kappa coefficient (κ), for radiographic findings and a correlation coefficient of Lin (CCC) for tomographic measurements was established. 12 radiographies and 19 tomographs were evaluated. The intraobserver consistency determined a k= 1 (Almost Perfect) and a CCC from 0.42 to 0.95 (Poor to Substantial) for both observation times. For radiographies, the interobserver concordance did not show changes between the first and second observation. Values include a k= 0.56-0.80 (Moderate to Good) and a CCC with greater degree of agreement, after training, as follows: axial view: CCC 0.86, 95% of Confidence Interval (CI) 0.69-0.94, coronal view: CCC 0.90 95%CI 0.75-0.96, and sagittal view: CCC 0.96, 95%CI 0.90-0.98. The statistical tests estimated the consistency and concordance to observe radiographically and tomographically the periapical tissue in endodontics.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2021-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21676/2389783x.4374","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To estimate the degree of concordance and consistency in the radiographic and tomographic evaluation of the periapical area. A study of diagnostic tests was designed. Three blind evaluators analyzed radiographic images, which were selected at two different points in time. An oral radiologist and an endodontist determined the second observation moment. The degree of similarity and variability, concordance and consistency for each radiograph was set at 95% confidence. A Kappa coefficient (κ), for radiographic findings and a correlation coefficient of Lin (CCC) for tomographic measurements was established. 12 radiographies and 19 tomographs were evaluated. The intraobserver consistency determined a k= 1 (Almost Perfect) and a CCC from 0.42 to 0.95 (Poor to Substantial) for both observation times. For radiographies, the interobserver concordance did not show changes between the first and second observation. Values include a k= 0.56-0.80 (Moderate to Good) and a CCC with greater degree of agreement, after training, as follows: axial view: CCC 0.86, 95% of Confidence Interval (CI) 0.69-0.94, coronal view: CCC 0.90 95%CI 0.75-0.96, and sagittal view: CCC 0.96, 95%CI 0.90-0.98. The statistical tests estimated the consistency and concordance to observe radiographically and tomographically the periapical tissue in endodontics.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
牙髓病根尖周组织诊断图像评价的一致性和一致性
目的评估根尖周围区域的x线和层析评价的一致性和一致性程度。设计了一项诊断试验的研究。三名盲评者分析了两个不同时间点的放射影像。口腔放射科医生和牙髓科医生确定了第二次观察时间。每张x光片的相似性和可变性、一致性和一致性的程度设置为95%置信度。建立了用于x线表现的Kappa系数(κ)和用于层析测量的Lin相关系数(CCC)。12张x线片和19张断层片进行了评估。观察者内部一致性决定了两个观察时间的k= 1(几乎完美)和CCC从0.42到0.95(差到实质性)。对于x光片,观察者之间的一致性没有显示第一次和第二次观察之间的变化。训练后的值包括k= 0.56-0.80(中度至良好)和更一致程度的CCC,如下:轴位视图:CCC 0.86, 95%可信区间(CI) 0.69-0.94,冠状视图:CCC 0.90 95%CI 0.75-0.96,矢状视图:CCC 0.96, 95%CI 0.90-0.98。统计检验估计了根管学中根尖周组织的x线和层析观察结果的一致性和一致性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1