RestEaze: An Emerging Technology to Characterize Leg Movements During Sleep

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical Devices-Transactions of the Asme Pub Date : 2021-12-06 DOI:10.1115/1.4053160
Justin Brooks, C. Feltch, J. Lam, C. Earley, R. Robucci, Sanjay Agarwal, Nilanjan Banerjee
{"title":"RestEaze: An Emerging Technology to Characterize Leg Movements During Sleep","authors":"Justin Brooks, C. Feltch, J. Lam, C. Earley, R. Robucci, Sanjay Agarwal, Nilanjan Banerjee","doi":"10.1115/1.4053160","DOIUrl":null,"url":null,"abstract":"\n Several sleep disorders are characterized by periodic leg movements during sleep including Restless Leg Syndrome, and can indicate disrupted sleep in otherwise healthy individuals. Current technologies to measure periodic leg movements during sleep are limited. Polysomnography and some home sleep tests use surface electromyography to measure electrical activity from the anterior tibilias muscle. Actigraphy uses 3-axis accelerometers to measure movement of the ankle. Electromyography misses periodic leg movements that involve other leg muscles and is obtrusive because of the wires needed to carry the signal. Actigraphy based devices require large amplitude movements of the ankle to detect leg movements (missing the significant number of more subtle leg movements) and can be worn in multiple configurations precluding precision measurement. These limitations have contributed to their lack of adoption as a standard of care for several sleep disorders. In this study, we develop the RestEaze sleep assessment tool as an ankle-worn wearable device that combines capacitive sensors and a 6-axis inertial measurement unit to precisely measure periodic leg movements during sleep. This unique combination of sensors and the form-factor of the device addresses current limitations of periodic leg movements during sleep measurement techniques. Pilot data collected shows high correlation with polysomnography across a heterogeneous participant sample and high usability ratings. RestEaze shows promise in providing ecologically valid, longitudinal measures of leg movements that will be useful for clinicians, researchers, and patients to better understand sleep.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2021-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4053160","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Several sleep disorders are characterized by periodic leg movements during sleep including Restless Leg Syndrome, and can indicate disrupted sleep in otherwise healthy individuals. Current technologies to measure periodic leg movements during sleep are limited. Polysomnography and some home sleep tests use surface electromyography to measure electrical activity from the anterior tibilias muscle. Actigraphy uses 3-axis accelerometers to measure movement of the ankle. Electromyography misses periodic leg movements that involve other leg muscles and is obtrusive because of the wires needed to carry the signal. Actigraphy based devices require large amplitude movements of the ankle to detect leg movements (missing the significant number of more subtle leg movements) and can be worn in multiple configurations precluding precision measurement. These limitations have contributed to their lack of adoption as a standard of care for several sleep disorders. In this study, we develop the RestEaze sleep assessment tool as an ankle-worn wearable device that combines capacitive sensors and a 6-axis inertial measurement unit to precisely measure periodic leg movements during sleep. This unique combination of sensors and the form-factor of the device addresses current limitations of periodic leg movements during sleep measurement techniques. Pilot data collected shows high correlation with polysomnography across a heterogeneous participant sample and high usability ratings. RestEaze shows promise in providing ecologically valid, longitudinal measures of leg movements that will be useful for clinicians, researchers, and patients to better understand sleep.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
RestEaze:一种描述睡眠中腿部运动的新兴技术
一些睡眠障碍的特征是睡眠中周期性的腿部运动,包括不宁腿综合征,这可能表明在其他健康个体中睡眠中断。目前测量睡眠期间腿部周期性运动的技术是有限的。多导睡眠图和一些家庭睡眠测试使用表面肌电图来测量胫骨前肌的电活动。活动记录仪使用3轴加速度计来测量脚踝的运动。肌电图忽略了涉及其他腿部肌肉的周期性腿部运动,并且由于需要携带信号的电线而显得突兀。基于活动仪的设备需要踝关节的大幅度运动来检测腿部运动(忽略了大量更细微的腿部运动),并且可以在多种配置中佩戴,从而妨碍了精确测量。这些限制导致它们没有被采纳为治疗几种睡眠障碍的标准。在这项研究中,我们开发了RestEaze睡眠评估工具,作为一种踝关节穿戴式可穿戴设备,它结合了电容传感器和6轴惯性测量单元,以精确测量睡眠期间的周期性腿部运动。这种独特的传感器组合和设备的形状因素解决了当前睡眠测量技术中周期性腿部运动的局限性。收集的试点数据显示,在异质参与者样本和高可用性评级中,多导睡眠图具有高度相关性。RestEaze有望为临床医生、研究人员和患者更好地了解睡眠提供生态学上有效的、纵向的腿部运动测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
期刊最新文献
A Novel Design Method for the Knee Joint of the Exoskeleton Based On the Modular Wearable Sensor Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures Development And Mechanical Testing Of Implant For Cranial Reconstruction After Burr Hole Trepanation In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1