Fabrication of nitrate ion sensor based on conductive polyaniline doped with nitrate using thick film technology

Charlotha Charlotha, R. V. Manurung, Aminuddin Debataraja, I. Dwisaputra, Subkhan Subkhan, I. Syamsu
{"title":"Fabrication of nitrate ion sensor based on conductive polyaniline doped with nitrate using thick film technology","authors":"Charlotha Charlotha, R. V. Manurung, Aminuddin Debataraja, I. Dwisaputra, Subkhan Subkhan, I. Syamsu","doi":"10.14203/j.mev.2022.v13.72-78","DOIUrl":null,"url":null,"abstract":"Nitrate is one of the nutrients that can give an effect on the environment if it is applied in excess. It is also easily soluble in water and it has the potential to be a pollutant in groundwater by the over-process of fertilizer. Therefore, it needs a detected component to give the right measure for nitrate in the soil, called a nitrate ion sensor. It consists of three electrodes configuration, namely, working, counter, and reference electrodes with conductive polyaniline doped with Nitrate (NO₃‾) which is fabricated by thick film technology. In previous research, acidic media was used as a solvent for polyaniline, while this research used water (H2O) solvent. The result of characterization showed that particles were distributed evenly on the sample with the form of particles being small balls with a dimension of 0.18 µm and the percentage of atomic elements being: 91.96 % carbon, 3.14 % nitrogen, and 4.9 % oxygen. The performance of sensors was investigated using potentiostat with four concentrations of nitrate standard solution. The result showed good response with a voltage range in each concentration of nitrate standard solution being 0.5002 Volt (10 mg/l), 1.3552 Volt (20 mg/l), 1.1208 Volt (50 mg/l), and 0.8963 Volt (100 mg/l). It was found that nitrate sensors with nitrate-doped conductive polymer, polyaniline, as the sensitive membrane responded well to detecting nitrate elements in precision farming and the sensitivity showed that for every 1 mg/l concentration in nitrate standard solution, the voltage increases by 0.0007.","PeriodicalId":30530,"journal":{"name":"Journal of Mechatronics Electrical Power and Vehicular Technology","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mechatronics Electrical Power and Vehicular Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14203/j.mev.2022.v13.72-78","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Nitrate is one of the nutrients that can give an effect on the environment if it is applied in excess. It is also easily soluble in water and it has the potential to be a pollutant in groundwater by the over-process of fertilizer. Therefore, it needs a detected component to give the right measure for nitrate in the soil, called a nitrate ion sensor. It consists of three electrodes configuration, namely, working, counter, and reference electrodes with conductive polyaniline doped with Nitrate (NO₃‾) which is fabricated by thick film technology. In previous research, acidic media was used as a solvent for polyaniline, while this research used water (H2O) solvent. The result of characterization showed that particles were distributed evenly on the sample with the form of particles being small balls with a dimension of 0.18 µm and the percentage of atomic elements being: 91.96 % carbon, 3.14 % nitrogen, and 4.9 % oxygen. The performance of sensors was investigated using potentiostat with four concentrations of nitrate standard solution. The result showed good response with a voltage range in each concentration of nitrate standard solution being 0.5002 Volt (10 mg/l), 1.3552 Volt (20 mg/l), 1.1208 Volt (50 mg/l), and 0.8963 Volt (100 mg/l). It was found that nitrate sensors with nitrate-doped conductive polymer, polyaniline, as the sensitive membrane responded well to detecting nitrate elements in precision farming and the sensitivity showed that for every 1 mg/l concentration in nitrate standard solution, the voltage increases by 0.0007.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于导电聚苯胺掺杂硝酸盐的硝酸盐离子传感器的厚膜制备
硝酸盐是一种如果过量施用会对环境产生影响的营养物质。它也很容易溶于水,并且有可能通过肥料的过度处理成为地下水中的污染物。因此,它需要一种被检测的组件来对土壤中的硝酸盐进行正确的测量,称为硝酸盐离子传感器。它由三种电极配置组成,即工作电极、计数器电极和参比电极,电极的导电聚苯胺掺杂硝酸(NO₃),由厚膜技术制成。以往的研究多采用酸性介质作为聚苯胺的溶剂,而本研究采用水(H2O)溶剂。表征结果表明,颗粒均匀分布在样品上,颗粒形态为尺寸为0.18µm的小球,原子元素的百分比为:碳91.96%,氮3.14%,氧4.9%。采用恒电位器对四种浓度的硝酸标准溶液进行了传感器性能的研究。结果表明,在硝酸盐标准溶液浓度为0.5002伏特(10 mg/l)、1.3552伏特(20 mg/l)、1.1208伏特(50 mg/l)、0.8963伏特(100 mg/l)的电压范围内,反应良好。结果表明,以硝酸盐掺杂导电聚合物聚苯胺为敏感膜的硝酸盐传感器对精准农业中硝酸盐元素的检测反应良好,灵敏度表明,硝酸盐标准溶液中浓度每增加1 mg/l,电压增加0.0007。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
10
期刊最新文献
Five-axis parallel mechanism system (PMS) CNC partial link control system based on modified inverse kinematic of 6-DOF UPS parallel manipulator Impact of road load parameters on vehicle CO₂ emissions and fuel economy: A case study in Indonesia LSTM-based forecasting on electric vehicles battery swapping demand: Addressing infrastructure challenge in Indonesia Stability analysis of a hybrid DC-DC buck converter model using dissipation inequality and convex optimization Artificial intelligence in smart grids: A bibliometric analysis and scientific mapping study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1