Comparison of Transcorneal and Transpalpebral Ultrasonographic Measurements of the Eye in Iranian Mix Breed Dog

R. Vali, M. Razeghi
{"title":"Comparison of Transcorneal and Transpalpebral Ultrasonographic Measurements of the Eye in Iranian Mix Breed Dog","authors":"R. Vali, M. Razeghi","doi":"10.22034/IVSA.2019.154146.1165","DOIUrl":null,"url":null,"abstract":"Objective-The aim of this research was to compare transcorneal and transpalpebral ultrasonography study of the dimensions (ecobiometry) and the ultrasonographic aspect of Iranian mix breed dogs.Design- Experimental studyAnimals- . Ten adult male dogsProcedure- Ten adult male dogs with the mean age 4±1.39 years and the mean weight of 16.7±3.6 kg were selected and distributed in two equal groups. Transcorneal and transpalpebral ultrasonographic scanning of left and right eyes of dogs were performed using with a 12 MHZ transducer. The transducer was placed in a longitudinal position (sagittal plane) until optimal B-scan images, were obtained.Results- Means and standard deviations of the intraocular structures of both transcorneal and transpalpebral were as, Anterior chamber depth (2.99±0.242, 2.78±0.285 mm), Lens thickness (6.62±0.364,7.02±0.612 mm), Vitreous chamber depth (8.81±0.354, 8.79±0.552 mm) and Axial globe length (19.60±0.452,19.50±0.592 mm) respectively. No significant differences were observed when comparing left and right eyes of dogs in both methods within the same group and comparing between two groups (p>0.05).Conclusion and Clinical Relevance- Results of this study can be used as a template in diagnosis of ocular disease and facilitates the use of transpalpebral ultrasonography in the evaluation of ocular structures in ocular disease specially painful conditions.","PeriodicalId":14554,"journal":{"name":"Iranian Journal of Veterinary Surgery","volume":"14 1","pages":"91-96"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Veterinary Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22034/IVSA.2019.154146.1165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Veterinary","Score":null,"Total":0}
引用次数: 0

Abstract

Objective-The aim of this research was to compare transcorneal and transpalpebral ultrasonography study of the dimensions (ecobiometry) and the ultrasonographic aspect of Iranian mix breed dogs.Design- Experimental studyAnimals- . Ten adult male dogsProcedure- Ten adult male dogs with the mean age 4±1.39 years and the mean weight of 16.7±3.6 kg were selected and distributed in two equal groups. Transcorneal and transpalpebral ultrasonographic scanning of left and right eyes of dogs were performed using with a 12 MHZ transducer. The transducer was placed in a longitudinal position (sagittal plane) until optimal B-scan images, were obtained.Results- Means and standard deviations of the intraocular structures of both transcorneal and transpalpebral were as, Anterior chamber depth (2.99±0.242, 2.78±0.285 mm), Lens thickness (6.62±0.364,7.02±0.612 mm), Vitreous chamber depth (8.81±0.354, 8.79±0.552 mm) and Axial globe length (19.60±0.452,19.50±0.592 mm) respectively. No significant differences were observed when comparing left and right eyes of dogs in both methods within the same group and comparing between two groups (p>0.05).Conclusion and Clinical Relevance- Results of this study can be used as a template in diagnosis of ocular disease and facilitates the use of transpalpebral ultrasonography in the evaluation of ocular structures in ocular disease specially painful conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
伊朗混血犬经角膜和经眼睑超声检查的比较
目的:比较伊朗混交种犬经角膜和经睑超声对其外形(生物计量学)和超声方面的研究。设计-实验研究-动物-。方法:选取平均年龄(4±1.39)岁、平均体重(16.7±3.6)kg的成年雄性犬10只,随机分为两组。采用12 MHZ换能器对犬左右眼进行经角膜和经眼睑超声扫描。换能器放置在纵向位置(矢状面),直到获得最佳的b扫描图像。结果:经角膜和经眼睑的眼内结构的均值和标准差分别为:前房深度(2.99±0.242,2.78±0.285 mm)、晶状体厚度(6.62±0.364,7.02±0.612 mm)、玻璃体深度(8.81±0.354,8.79±0.552 mm)和眼轴长度(19.60±0.452,19.50±0.592 mm)。两种方法在同一组内、两组间左、右眼比较,差异均无统计学意义(p < 0.05)。结论及临床意义-本研究结果可作为眼部疾病诊断的模板,促进经睑超声在眼部疾病特别是疼痛情况下对眼部结构的评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
审稿时长
30 weeks
期刊最新文献
Effects of intraperitoneal administration of polyethylene glycol solution on ischemia-reperfusion injury in rat testicular torsion and detorsion model Effect of Cinnamon Nanoparticles in Presence of HAMLET on the Healing of Wounds Infected with Pseudomonas aeruginosa: An Animal Model Study Evaluation of Clinical Signs, Hematological and Biochemical Parameters after Blood Transfusion from Sheep to Goat Coronal Rhytidectomy for Correction of Bilateral Superior Entropion in Dogs with Redundant Eyebrow Droop - A Review of Two Cases Ultrasonographic and Cystographic Evaluations of Urinary Bladder Defects Managed with Composite Colo-Peritoneal Grafts in Dogs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1