Calibration features for power meters of high and microwave frequencies

IF 0.1 Q4 INSTRUMENTS & INSTRUMENTATION Ukrainian Metrological Journal Pub Date : 2022-06-30 DOI:10.24027/2306-7039.2.2022.263724
O. Velychko, Valentyn Gaman, Serhii Kursin
{"title":"Calibration features for power meters of high and microwave frequencies","authors":"O. Velychko, Valentyn Gaman, Serhii Kursin","doi":"10.24027/2306-7039.2.2022.263724","DOIUrl":null,"url":null,"abstract":"Microwave frequency power measurement is one of the main types of the measurement for measuring instruments and systems in the radio frequency range. Therefore, improving the accuracy of measuring the microwave frequency power requires the establishment of more precise standards, and the development of calibration methods for meters of microwave frequency power is an urgent task. Microwave frequency power standards that are used to calibrate the relevant measuring instruments must ensure high accuracy of the unit size reproduction over a wide measurement and frequency range. \nThe study allowed determining typical calibration schemes for meters of microwave frequency power. For measurements, the calibration scheme for meters of microwave frequency power by the method of a direct comparison with the help of a calibrator when measuring the absorbed power of microwave frequencies is substantiated and suggested. \nThe proposed methodology for evaluating the uncertainty of absorbed power measurements can be used when calibrating power meters in the frequency range from 30 MHz to 18 GHz. It allows determining the most significant components of the combined standard uncertainty of the absorbed power measurements of ultrahigh frequencies, as well as to receive the result of the corresponding calibration. This methodology can also be used to evaluate the uncertainty of microwave frequency directional measurements.","PeriodicalId":40775,"journal":{"name":"Ukrainian Metrological Journal","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ukrainian Metrological Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24027/2306-7039.2.2022.263724","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 1

Abstract

Microwave frequency power measurement is one of the main types of the measurement for measuring instruments and systems in the radio frequency range. Therefore, improving the accuracy of measuring the microwave frequency power requires the establishment of more precise standards, and the development of calibration methods for meters of microwave frequency power is an urgent task. Microwave frequency power standards that are used to calibrate the relevant measuring instruments must ensure high accuracy of the unit size reproduction over a wide measurement and frequency range. The study allowed determining typical calibration schemes for meters of microwave frequency power. For measurements, the calibration scheme for meters of microwave frequency power by the method of a direct comparison with the help of a calibrator when measuring the absorbed power of microwave frequencies is substantiated and suggested. The proposed methodology for evaluating the uncertainty of absorbed power measurements can be used when calibrating power meters in the frequency range from 30 MHz to 18 GHz. It allows determining the most significant components of the combined standard uncertainty of the absorbed power measurements of ultrahigh frequencies, as well as to receive the result of the corresponding calibration. This methodology can also be used to evaluate the uncertainty of microwave frequency directional measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高频和微波功率计的校准特性
微波频率功率测量是射频范围内测量仪器和系统的主要测量类型之一。因此,提高微波频率功率测量的准确性需要建立更精确的标准,而开发微波频率功率计的校准方法是一项紧迫的任务。用于校准相关测量仪器的微波频率功率标准必须确保在宽测量和频率范围内单位尺寸复制的高精度。该研究允许确定微波频率功率计的典型校准方案。对于测量,在测量微波频率的吸收功率时,通过校准器的帮助下直接比较的方法对微波频率功率计的校准方案得到了证实和建议。所提出的评估吸收功率测量不确定度的方法可用于校准频率范围为30MHz至18GHz的功率表。它允许确定超高频吸收功率测量的组合标准不确定度的最重要分量,并接收相应校准的结果。该方法也可用于评估微波频率方向测量的不确定度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Ukrainian Metrological Journal
Ukrainian Metrological Journal INSTRUMENTS & INSTRUMENTATION-
自引率
0.00%
发文量
21
期刊最新文献
A statistical method for the assessment of metrological characteristics of reference materials Study of metrological characteristics of the state primary measurement standard of volume flow and mass consumption of liquid in preparation for participation in international comparisons The estimation of the long-term drift of the inductance measurement standards Study of reading errors when calibrating analog ohmmeters Modern approaches to studying the accuracy of determination of deformation values in geodesic monitoring of crane equipment
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1