W. Quitiaquez, José Estupiñan-Campos, C.A. Isaza Roldán, Fernando Toapanta-Ramos, Andrés Lobato-Campoverde
{"title":"Análisis numérico de un sistema de calentamiento de agua utilizando un colector solar de placa plana","authors":"W. Quitiaquez, José Estupiñan-Campos, C.A. Isaza Roldán, Fernando Toapanta-Ramos, Andrés Lobato-Campoverde","doi":"10.17163/ings.n24.2020.10","DOIUrl":null,"url":null,"abstract":"The objective of the present research work was to carry out a numerical analysis by means of CFD of a flat plate solar collector, in addition to a comparison with experimental results. The working fluid reached a maximum outlet temperature of 20.16 °C at 12:00, the value of solar radiation was determined for the geographical coordinates latitude -0.2252 and longitude -77.84; similarly, at this time it was possible to obtain a temperature of 27.12 °C on the collector surface, as peak value. The lowest performance of the heat transfer device was determined at 10:00 with an outlet water temperature and maximum temperature on the collector surface of 18.65 and 20.48 °C, respectively. The experimental results showed a maximum temperature of 20.93 °C and a minimum temperature of 19.4 °C, resulting in a 4.01 % error between the computational simulation and the experimental data.","PeriodicalId":53899,"journal":{"name":"Ingenius-Revista de Ciencia y Tecnologia","volume":"1 1","pages":"97-106"},"PeriodicalIF":0.4000,"publicationDate":"2020-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ingenius-Revista de Ciencia y Tecnologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17163/ings.n24.2020.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 7
Abstract
The objective of the present research work was to carry out a numerical analysis by means of CFD of a flat plate solar collector, in addition to a comparison with experimental results. The working fluid reached a maximum outlet temperature of 20.16 °C at 12:00, the value of solar radiation was determined for the geographical coordinates latitude -0.2252 and longitude -77.84; similarly, at this time it was possible to obtain a temperature of 27.12 °C on the collector surface, as peak value. The lowest performance of the heat transfer device was determined at 10:00 with an outlet water temperature and maximum temperature on the collector surface of 18.65 and 20.48 °C, respectively. The experimental results showed a maximum temperature of 20.93 °C and a minimum temperature of 19.4 °C, resulting in a 4.01 % error between the computational simulation and the experimental data.