CT VS MR Attenuation Correction: A Systematic Review on PET Image Quality Assessment

Rukiah A LATIFF, Mohd Izuan Ibrahim, Mohammad Aizart Rosli, Nur Farahana Najwa ELYAS YEOW
{"title":"CT VS MR Attenuation Correction: A Systematic Review on PET Image Quality Assessment","authors":"Rukiah A LATIFF, Mohd Izuan Ibrahim, Mohammad Aizart Rosli, Nur Farahana Najwa ELYAS YEOW","doi":"10.17576/jskm-2023-2102-07","DOIUrl":null,"url":null,"abstract":"This systematic review was conducted to evaluate the image quality performance when implementing computed tomography data (CTAC) or magnetic resonance data for attenuation correction (MRAC) on positron emission tomography (PET) images. The CTAC and MRAC were performed on image from PET/CT and PET/MR scanners, respectively. The systematic review was done based on Preferred Reporting Items for Systematic Reviews (PRISMA). In this study, twelve articles were included from six databases. The image performance was evaluated by overall image quality, contrast, spatial resolution, detectability, standardised uptake value (SUV) and acquisition time. Data was shown as mean ± standard deviation and compared between CTAC and MRAC images to determine which attenuation correction method provides better image quality. Results found that PET-CTAC and PET-MRAC have similar image performance in overall image quality (p=0.93), detectabilty (p=0.84), SUVmean (p=0.84) and SUVmax (p=0.81). Meanwhile, PET-CTAC acquisition time is significantly faster than PET-MRAC by approximately two fold (p <0.05). There were no statistical analyses performed for image contrast, spatial resolution and contrast-noise-ratio due to the insufficient data. In conclusion, although PET/CT is faster than PET/MRI procedure, images yielded from CTAC and MRAC are equivalent to each other. Due to the variation of linear attenuation coefficient for each type of tissue, future review of image quality comparison can be done focusing on specific tissue or region such as soft tissue, bone and lungs to reflect the real impact of CTAC and MRAC on PET image.","PeriodicalId":17686,"journal":{"name":"Jurnal Sains Kesihatan Malaysia","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Sains Kesihatan Malaysia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17576/jskm-2023-2102-07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This systematic review was conducted to evaluate the image quality performance when implementing computed tomography data (CTAC) or magnetic resonance data for attenuation correction (MRAC) on positron emission tomography (PET) images. The CTAC and MRAC were performed on image from PET/CT and PET/MR scanners, respectively. The systematic review was done based on Preferred Reporting Items for Systematic Reviews (PRISMA). In this study, twelve articles were included from six databases. The image performance was evaluated by overall image quality, contrast, spatial resolution, detectability, standardised uptake value (SUV) and acquisition time. Data was shown as mean ± standard deviation and compared between CTAC and MRAC images to determine which attenuation correction method provides better image quality. Results found that PET-CTAC and PET-MRAC have similar image performance in overall image quality (p=0.93), detectabilty (p=0.84), SUVmean (p=0.84) and SUVmax (p=0.81). Meanwhile, PET-CTAC acquisition time is significantly faster than PET-MRAC by approximately two fold (p <0.05). There were no statistical analyses performed for image contrast, spatial resolution and contrast-noise-ratio due to the insufficient data. In conclusion, although PET/CT is faster than PET/MRI procedure, images yielded from CTAC and MRAC are equivalent to each other. Due to the variation of linear attenuation coefficient for each type of tissue, future review of image quality comparison can be done focusing on specific tissue or region such as soft tissue, bone and lungs to reflect the real impact of CTAC and MRAC on PET image.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CT与MR衰减校正:PET图像质量评估的系统评价
本系统综述旨在评估在正电子发射断层扫描(PET)图像上使用计算机断层扫描数据(CTAC)或磁共振数据进行衰减校正(MRAC)时的图像质量性能。CTAC和MRAC分别在PET/CT和PET/MR扫描仪上进行。系统评价以系统评价首选报告项目(PRISMA)为基础。本研究纳入了6个数据库中的12篇文章。通过整体图像质量、对比度、空间分辨率、可检测性、标准化摄取值(SUV)和采集时间来评估图像性能。数据以均数±标准差表示,比较CTAC和MRAC图像,以确定哪种衰减校正方法能提供更好的图像质量。结果发现PET-CTAC和PET-MRAC在整体图像质量(p=0.93)、可检出性(p=0.84)、SUVmean (p=0.84)和SUVmax (p=0.81)方面具有相似的图像性能。同时,PET-CTAC的获取时间显著快于PET-MRAC约2倍(p <0.05)。由于数据不足,未对图像对比度、空间分辨率和比噪比进行统计分析。综上所述,尽管PET/CT比PET/MRI更快,但CTAC和MRAC产生的图像是等效的。由于不同类型组织的线性衰减系数存在差异,因此在以后的图像质量比较综述中,可以针对特定的组织或区域,如软组织、骨骼、肺部进行比较,以反映CTAC和MRAC对PET图像的真实影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
30
审稿时长
12 weeks
期刊最新文献
Jujube in Malay Medical Manuscript: A comparison from Scientific and Islamic Perspectives Impact of a Tailored Self-Management Education Programme for Older Adults with Knee Osteoarthritis in a Multi-Ethnic Country THE CORRELATION BETWEEN THE INTENSITY OF INSTAGRAM USAGE AND ORTHOREXIA NERVOSA IN UNIVERSITAS GADJAH MADA STUDENTS The electroacoustic performance of digital noise reduction systems in commercial hearing aids with Malay speech-plus-noise test signals THE BENEFIT OF GARLIC FROM ISLAMIC PERSPECTIVE AND MALAY PRACTISE
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1