High-precision intermode beating electro-optic distance measurement for mitigation of atmospheric delays

IF 1.2 Q4 REMOTE SENSING Journal of Applied Geodesy Pub Date : 2023-01-04 DOI:10.1515/jag-2022-0039
Pabitro Ray, D. Salido-Monzú, A. Wieser
{"title":"High-precision intermode beating electro-optic distance measurement for mitigation of atmospheric delays","authors":"Pabitro Ray, D. Salido-Monzú, A. Wieser","doi":"10.1515/jag-2022-0039","DOIUrl":null,"url":null,"abstract":"Abstract High-precision electro-optic distance measurement (EDM) is essential for deformation monitoring. Although sub-ppm instrumental accuracy is already feasible with state-of-the-art commercial technology, the practically attainable accuracy on distances over more than a few hundred meters is limited by uncertainties in estimating the integral refractive index along the propagation path, which often results in measurement errors of several ppm. This paper presents a new instrumental basis for high-accuracy multispectral EDM using an optical supercontinuum to enable dispersion-based inline refractivity compensation. Initial experiments performed on two spectrally filtered bands of 590 and 890 nm from the supercontinuum show measurement precision better than 0.05 mm over 50 m for an acquisition time of around 3 ms on the individual bands. This represents a comparable performance to our previously reported results on 5 cm by over a range of 3 orders of magnitude longer, which can still be improved by increasing the acquisition time. The preliminary results indicate a relative accuracy of about 0.1 mm at 50 m on each wavelength. Improvement is possible by calibration and by implementing a self-reference scheme that mitigates slow drifts caused by power-to-phase coupling. The results reported herein thus indicate that the presented approach can be further developed for achieving sub-ppm accuracy of refractivity compensated distance measurements on practically useful ranges and under outdoor conditions.","PeriodicalId":45494,"journal":{"name":"Journal of Applied Geodesy","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2023-01-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Geodesy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/jag-2022-0039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"REMOTE SENSING","Score":null,"Total":0}
引用次数: 5

Abstract

Abstract High-precision electro-optic distance measurement (EDM) is essential for deformation monitoring. Although sub-ppm instrumental accuracy is already feasible with state-of-the-art commercial technology, the practically attainable accuracy on distances over more than a few hundred meters is limited by uncertainties in estimating the integral refractive index along the propagation path, which often results in measurement errors of several ppm. This paper presents a new instrumental basis for high-accuracy multispectral EDM using an optical supercontinuum to enable dispersion-based inline refractivity compensation. Initial experiments performed on two spectrally filtered bands of 590 and 890 nm from the supercontinuum show measurement precision better than 0.05 mm over 50 m for an acquisition time of around 3 ms on the individual bands. This represents a comparable performance to our previously reported results on 5 cm by over a range of 3 orders of magnitude longer, which can still be improved by increasing the acquisition time. The preliminary results indicate a relative accuracy of about 0.1 mm at 50 m on each wavelength. Improvement is possible by calibration and by implementing a self-reference scheme that mitigates slow drifts caused by power-to-phase coupling. The results reported herein thus indicate that the presented approach can be further developed for achieving sub-ppm accuracy of refractivity compensated distance measurements on practically useful ranges and under outdoor conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于缓解大气延迟的高精度互调拍频电光距离测量
摘要高精度光电测距是变形监测的关键。尽管使用最先进的商业技术,亚ppm仪器精度已经是可行的,但在超过几百米的距离上实际可达到的精度受到沿传播路径估计积分折射率的不确定性的限制,这通常会导致几个ppm的测量误差。本文提出了一种新的高精度多光谱电火花加工仪器基础,该仪器使用光学超连续谱实现基于色散的在线折射率补偿。在来自超连续谱的590和890nm的两个光谱滤波带上进行的初始实验显示,在单个带上约3ms的采集时间内,在50m范围内的测量精度优于0.05mm。这代表了与我们之前报道的5厘米长3个数量级的结果相当的性能,这仍然可以通过增加采集时间来改善。初步结果表明,在每个波长50米处的相对精度约为0.1毫米。可以通过校准和实施自参考方案来进行改进,该方案减轻了由功率-相位耦合引起的缓慢漂移。因此,本文报告的结果表明,所提出的方法可以进一步发展,用于在实际有用的范围内和室外条件下实现折射率补偿距离测量的亚ppm精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Applied Geodesy
Journal of Applied Geodesy REMOTE SENSING-
CiteScore
2.30
自引率
7.10%
发文量
30
期刊最新文献
Occurrence characteristics of ionospheric scintillations in the civilian GPS signals (L1, L2, and L5) through a dedicated scintillation monitoring receiver at a low-latitude location in India during the 25th solar cycle A new challenge for cadastral surveying in Taiwan: feasibility analysis using combination on CORS data and online PPP service Monitoring of a rockfill embankment dam using TLS and sUAS point clouds Analyzing recent deformation in Wadi Hagul, Eastern Desert, Egypt, via advanced remote sensing and geodetic data processing Regional evaluation of global geopotential models and three types of digital elevation models with ground-based gravity and GNSS/levelling data using several techniques over Sudan
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1