{"title":"Surface Microhardness of Different Ceramic Materials Used for Esthetic Full-Ceramic Veneers","authors":"Esraa A. Attar, Ayman Aldharrab, Reem Ajaj","doi":"10.1166/jbt.2023.3298","DOIUrl":null,"url":null,"abstract":"The study examines the microhardness of five ceramic materials using CAD-CAM technology. Twenty-five disc-shaped specimens for the study, using I.P.S. Empress CAD (fully sintered), I.P.S. e.max CAD (30 minutes) and Vita Suprinity (26 minutes) milled in a pre-crystallized stage, Coprasmile\n (8 hours), and Zenostar milled in partially sintered stage (9 hours and 50 minutes). Each specimen had ten indentations, with a 1000-gram load applied for 10 seconds using a Vickers diamond indenter. Vickers values were automatically converted to microhardness using the formula Hv = 1.8544×F/d2.\n IBM SPSS 26 for statistical analysis, calculating microhardness values for each group. One-way ANOVA and Tukey HSD posthoc test compared differences between ceramic groups at a P <0.05 significance level. Results showed significant differences among the means (P <0.05),\n with Coprasmile, Zenostar, and Suprinity groups having the highest and lowest values, respectively.","PeriodicalId":15300,"journal":{"name":"Journal of Biomaterials and Tissue Engineering","volume":" ","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomaterials and Tissue Engineering","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1166/jbt.2023.3298","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The study examines the microhardness of five ceramic materials using CAD-CAM technology. Twenty-five disc-shaped specimens for the study, using I.P.S. Empress CAD (fully sintered), I.P.S. e.max CAD (30 minutes) and Vita Suprinity (26 minutes) milled in a pre-crystallized stage, Coprasmile
(8 hours), and Zenostar milled in partially sintered stage (9 hours and 50 minutes). Each specimen had ten indentations, with a 1000-gram load applied for 10 seconds using a Vickers diamond indenter. Vickers values were automatically converted to microhardness using the formula Hv = 1.8544×F/d2.
IBM SPSS 26 for statistical analysis, calculating microhardness values for each group. One-way ANOVA and Tukey HSD posthoc test compared differences between ceramic groups at a P <0.05 significance level. Results showed significant differences among the means (P <0.05),
with Coprasmile, Zenostar, and Suprinity groups having the highest and lowest values, respectively.