A comparative study on the use of a three-dimensional visualization operative planning system in Ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas
Yun Chen, Song Zhou, Xin Li, Fang-yi Liu, Zhigang Cheng, Jie Yu, Z. Han, Li-nan Dong, P. Liang, Xiaoling Yu
{"title":"A comparative study on the use of a three-dimensional visualization operative planning system in Ultrasound-guided percutaneous microwave ablation for large hepatic hemangiomas","authors":"Yun Chen, Song Zhou, Xin Li, Fang-yi Liu, Zhigang Cheng, Jie Yu, Z. Han, Li-nan Dong, P. Liang, Xiaoling Yu","doi":"10.3760/CMA.J.ISSN.1007-8118.2019.12.003","DOIUrl":null,"url":null,"abstract":"Objective \nTo study the use of a three dimensional (3D) visualization operative planning system in Ultrasound-guided percutaneous microwave ablation (US-PMWA) for large hepatic hemangiomas (LHHs). \n \n \nMethods \nA total of 50 patients with LHHs from January 2011 to August 2018 were included in Department of Interventional Ultrasound, the First Medical Center, Chinese PLA General Hospital, including 12 males and 38 females (age from 28.0~60.0, mean age was 43.0). Fifty patients with LHHs were divided into the 3D and 2D groups (25 cases in each group). The therapeutic efficacy was assessed by contrast-enhanced imagings on follow-up. Hepatic and renal functions were studied. The complete ablation, tumor volume shrinkage and complication rates were analyzed. \n \n \nResults \nThe levels of alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, and creatinine after ablation in the 3D group were significantly lower than the 2D group [(126.7±56.4)U/L vs. (204.7±76.5)U/L; (141.0±60.8)U/L vs. (206.6±77.4)U/L; (57.3±17.6)U/L vs. (86.2±46.1)U/L; (66.6±16.6)mmol/L vs. (86.8±42.8)mmol/L, P<0.05, respectively]. Compared with the 2D group, the ablation energy, ablation time and proportion of hemoglobinuria in the 3D group were all significantly less, while the complete ablation rate was significantly higher [(93.7±3.3)% vs. (97.7±2.4)%](all P<0.05). \n \n \nConclusion \nThe 3D visualization operative planning system provided a scientific, quantifiable, and individualized therapy for LHHs using US-PMWA. \n \n \nKey words: \nAblation techniques; Hemangioma; Liver; Three dimensional visualization operative planning system","PeriodicalId":10021,"journal":{"name":"中华肝胆外科杂志","volume":"25 1","pages":"890-893"},"PeriodicalIF":0.0000,"publicationDate":"2019-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华肝胆外科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1007-8118.2019.12.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
To study the use of a three dimensional (3D) visualization operative planning system in Ultrasound-guided percutaneous microwave ablation (US-PMWA) for large hepatic hemangiomas (LHHs).
Methods
A total of 50 patients with LHHs from January 2011 to August 2018 were included in Department of Interventional Ultrasound, the First Medical Center, Chinese PLA General Hospital, including 12 males and 38 females (age from 28.0~60.0, mean age was 43.0). Fifty patients with LHHs were divided into the 3D and 2D groups (25 cases in each group). The therapeutic efficacy was assessed by contrast-enhanced imagings on follow-up. Hepatic and renal functions were studied. The complete ablation, tumor volume shrinkage and complication rates were analyzed.
Results
The levels of alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase, and creatinine after ablation in the 3D group were significantly lower than the 2D group [(126.7±56.4)U/L vs. (204.7±76.5)U/L; (141.0±60.8)U/L vs. (206.6±77.4)U/L; (57.3±17.6)U/L vs. (86.2±46.1)U/L; (66.6±16.6)mmol/L vs. (86.8±42.8)mmol/L, P<0.05, respectively]. Compared with the 2D group, the ablation energy, ablation time and proportion of hemoglobinuria in the 3D group were all significantly less, while the complete ablation rate was significantly higher [(93.7±3.3)% vs. (97.7±2.4)%](all P<0.05).
Conclusion
The 3D visualization operative planning system provided a scientific, quantifiable, and individualized therapy for LHHs using US-PMWA.
Key words:
Ablation techniques; Hemangioma; Liver; Three dimensional visualization operative planning system
期刊介绍:
Chinese Journal of Hepatobiliary Surgery is an academic journal organized by the Chinese Medical Association and supervised by the China Association for Science and Technology, founded in 1995. The journal has the following columns: review, hot spotlight, academic thinking, thesis, experimental research, short thesis, case report, synthesis, etc. The journal has been recognized by Beida Journal (Chinese Journal of Humanities and Social Sciences).
Chinese Journal of Hepatobiliary Surgery has been included in famous databases such as Peking University Journal (Chinese Journal of Humanities and Social Sciences), CSCD Source Journals of China Science Citation Database (with Extended Version) and so on, and it is one of the national key academic journals under the supervision of China Association for Science and Technology.