Validation of a new model of non-invasive functional assessment of coronary lesions by computer tomography fractional flow reserve

Q4 Medicine REC: CardioClinics Pub Date : 2024-01-01 DOI:10.1016/j.rccl.2023.07.004
Alberto Otero-Cacho , Diego López-Otero , Manuel Insúa Villa , Brais Díaz-Fernández , María Bastos-Fernández , Vicente Pérez-Muñuzuri , Alberto P. Muñuzuri , José Ramón González-Juanatey
{"title":"Validation of a new model of non-invasive functional assessment of coronary lesions by computer tomography fractional flow reserve","authors":"Alberto Otero-Cacho ,&nbsp;Diego López-Otero ,&nbsp;Manuel Insúa Villa ,&nbsp;Brais Díaz-Fernández ,&nbsp;María Bastos-Fernández ,&nbsp;Vicente Pérez-Muñuzuri ,&nbsp;Alberto P. Muñuzuri ,&nbsp;José Ramón González-Juanatey","doi":"10.1016/j.rccl.2023.07.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction and objectives</h3><p>Computed tomography of coronary arteries (CTCA) is emerging as the gold standard in the initial evaluation of chest pain. The aim of this study is to calculate the diagnostic performance and clinical usefulness of numerical models of arterial channels flow to assess non-invasive coronary fractional flow reserve by computed tomography (FFRct) compared to assessment by invasive angiography (FFR).</p></div><div><h3>Methods</h3><p>Computation of FFR from CTCA images was performed on 39 vessels in 32 patients who followed the usual clinical protocol including invasive coronary angiography and FFR following the usual clinical protocol. From the segmentation of the CTCA images, 3D geometry is obtained, and computational fluid dynamics techniques are applied to accurately reproduce the circulation of blood considering steady and unsteady circulatory conditions. Additional parameters as wall shear stress, stenosis resistance index and ΔFFRct were also calculated.</p></div><div><h3>Results</h3><p>The results obtained show a good correlation between FFRct and invasive FFR, without obtaining false positives values. In addition, no differences were observed between the simulations considering steady conditions or those considering the transient. Additional parameters as wall shear stress, stenosis resistance, and ΔFFRct also showed a good correlation with the invasive values.</p></div><div><h3>Conclusions</h3><p>This new model for calculating the FFRct from non-invasive 3D medical images of coronary tree has shown good agreement with those obtained using invasive techniques. Parameters as wall shear stress, stenosis resistance and ΔFFRct provide useful information that could be helpful in medical decision-making in those situations with FFR values close to the cut-off zone.</p></div>","PeriodicalId":36870,"journal":{"name":"REC: CardioClinics","volume":"59 1","pages":"Pages 35-45"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"REC: CardioClinics","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2605153223002558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction and objectives

Computed tomography of coronary arteries (CTCA) is emerging as the gold standard in the initial evaluation of chest pain. The aim of this study is to calculate the diagnostic performance and clinical usefulness of numerical models of arterial channels flow to assess non-invasive coronary fractional flow reserve by computed tomography (FFRct) compared to assessment by invasive angiography (FFR).

Methods

Computation of FFR from CTCA images was performed on 39 vessels in 32 patients who followed the usual clinical protocol including invasive coronary angiography and FFR following the usual clinical protocol. From the segmentation of the CTCA images, 3D geometry is obtained, and computational fluid dynamics techniques are applied to accurately reproduce the circulation of blood considering steady and unsteady circulatory conditions. Additional parameters as wall shear stress, stenosis resistance index and ΔFFRct were also calculated.

Results

The results obtained show a good correlation between FFRct and invasive FFR, without obtaining false positives values. In addition, no differences were observed between the simulations considering steady conditions or those considering the transient. Additional parameters as wall shear stress, stenosis resistance, and ΔFFRct also showed a good correlation with the invasive values.

Conclusions

This new model for calculating the FFRct from non-invasive 3D medical images of coronary tree has shown good agreement with those obtained using invasive techniques. Parameters as wall shear stress, stenosis resistance and ΔFFRct provide useful information that could be helpful in medical decision-making in those situations with FFR values close to the cut-off zone.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
计算机断层分数血流储备对冠状动脉病变无创功能评估新模型的验证
导言和目的冠状动脉计算机断层扫描(CTCA)正在成为胸痛初步评估的金标准。本研究的目的是计算动脉通道流动数值模型的诊断性能和临床实用性,以评估计算机断层扫描(FFRct)与有创血管造影(FFR)评估相比的非侵入性冠状动脉分数血流储备。通过对 CTCA 图像进行分割,可获得三维几何图形,并应用计算流体动力学技术精确再现稳定和不稳定循环条件下的血液循环。结果显示,FFRct 与有创 FFR 之间具有良好的相关性,不会出现假阳性值。此外,在考虑稳定条件的模拟和考虑瞬态条件的模拟之间没有发现差异。其他参数如壁剪切应力、狭窄阻力和 ΔFFRct 也与有创值有很好的相关性。壁剪应力、狭窄阻力和 ΔFFRct 等参数提供了有用的信息,有助于在 FFR 值接近临界区域的情况下做出医疗决策。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
REC: CardioClinics
REC: CardioClinics Medicine-Cardiology and Cardiovascular Medicine
CiteScore
0.90
自引率
0.00%
发文量
79
审稿时长
33 days
期刊最新文献
Origen anómalo de la arteria pulmonar derecha en un adulto Characterizing the “iceberg peak” in valvular heart disease: Outcomes and costs of in-hospital procedures in Spain Non-invasive multiparametric assessment of intracardiac tumor Fibroelastoma papilar aórtico e ictus: un caso ilustrativo Underuse of systemic thrombolysis in pulmonary embolism: A single center retrospective observational study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1