{"title":"Transvenous Lead Extraction in a European Low-Volume Center without On-Site Surgical Support","authors":"Mohamed Dardari, C. Iorgulescu, V. Bataila, A. Deaconu, E. Cinteză, R. Vatasescu, Paul Padovani, C. Vasile, M. Dorobanțu","doi":"10.3390/reports6030041","DOIUrl":null,"url":null,"abstract":"Indications for cardiac implantable electronic devices (CIEDs) are increasing. Almost one-third of device-related infections are endocarditis. Transvenous lead extraction (TLE) has emerged as an effective and safe approach for treating device-related infections and complications. Multiple types of extraction tools are being used worldwide. Our goal is to evaluate the safety and effectiveness of TLE using non-powered extraction tools. The study included patients between October 2018 and July 2022 requiring TLE according to EHRA expert consensus recommendations on lead extraction. A total of 88 consecutive patients were included. Indications for TLE included device-related infections in 74% of the patients. Of those, 32% had device-related endocarditis with or without sepsis. Staphylococcus Aureus was the most frequent pathogen in patients with endocarditis and positive bacteremia, and 57% had negative bloodstream cultures. A total of 150 cardiac pacing and defibrillator leads were targeted for extraction. The mean dwell time for leads was 6.92 ± 4.4 years; 52.8% were older than 5 years, 15.8% were older than ten years, and the longest lead dwell time was 26 years. Patients’ age varied between 18 and 98, with a mean age of 66 ± 16 years. Sixty-seven percent of patients were males. Using only non-powered extraction tools, we report 93.3% complete lead removal and 99% clinical success with partial extraction. We report no procedure-related death nor major complications. Minor complication incidence was 6.8%, and all complications resolved spontaneously. The 30-day mortality rate was 3.4%. TLE using non-powered extraction tools is safe and effective even without surgical backup on site.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-09-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/reports6030041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Indications for cardiac implantable electronic devices (CIEDs) are increasing. Almost one-third of device-related infections are endocarditis. Transvenous lead extraction (TLE) has emerged as an effective and safe approach for treating device-related infections and complications. Multiple types of extraction tools are being used worldwide. Our goal is to evaluate the safety and effectiveness of TLE using non-powered extraction tools. The study included patients between October 2018 and July 2022 requiring TLE according to EHRA expert consensus recommendations on lead extraction. A total of 88 consecutive patients were included. Indications for TLE included device-related infections in 74% of the patients. Of those, 32% had device-related endocarditis with or without sepsis. Staphylococcus Aureus was the most frequent pathogen in patients with endocarditis and positive bacteremia, and 57% had negative bloodstream cultures. A total of 150 cardiac pacing and defibrillator leads were targeted for extraction. The mean dwell time for leads was 6.92 ± 4.4 years; 52.8% were older than 5 years, 15.8% were older than ten years, and the longest lead dwell time was 26 years. Patients’ age varied between 18 and 98, with a mean age of 66 ± 16 years. Sixty-seven percent of patients were males. Using only non-powered extraction tools, we report 93.3% complete lead removal and 99% clinical success with partial extraction. We report no procedure-related death nor major complications. Minor complication incidence was 6.8%, and all complications resolved spontaneously. The 30-day mortality rate was 3.4%. TLE using non-powered extraction tools is safe and effective even without surgical backup on site.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
欧洲小容量中心无现场手术支持的经静脉铅提取
心脏植入式电子装置(cied)的适应症正在增加。几乎三分之一的器械相关感染是心内膜炎。经静脉铅提取(TLE)已成为治疗器械相关感染和并发症的一种有效和安全的方法。世界范围内正在使用多种类型的提取工具。我们的目标是评估使用无动力拔牙工具进行TLE的安全性和有效性。该研究包括2018年10月至2022年7月期间需要TLE的患者,根据EHRA专家关于拔铅的共识建议。共纳入88例连续患者。TLE的适应症包括74%患者的器械相关感染。其中,32%患有与器械相关的心内膜炎,伴有或不伴有败血症。在心内膜炎和阳性菌血症患者中,金黄色葡萄球菌是最常见的病原体,57%的患者血液培养呈阴性。总共有150个心脏起搏和除颤器导联被选中进行提取。导联平均停留时间为6.92±4.4年;5岁以上的占52.8%,10岁以上的占15.8%,最长导联停留时间为26年。患者年龄18 ~ 98岁,平均66±16岁。67%的患者是男性。仅使用非动力拔牙工具,我们报告了93.3%的导联完全去除和99%的部分拔牙临床成功率。我们没有报告手术相关死亡或重大并发症。轻微并发症发生率为6.8%,所有并发症均自行消退。30天死亡率为3.4%。使用无动力拔牙工具的TLE即使在没有手术支持的情况下也是安全有效的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1