A corrosion threshold-controllable sensing system of Fe-C coated long period fiber gratings for life-cycle mass loss measurement of steel bars with strain and temperature compensation

IF 2.1 3区 工程技术 Q2 ENGINEERING, CIVIL Smart Structures and Systems Pub Date : 2021-10-01 DOI:10.12989/SSS.2021.28.4.443
Chuanrui Guo, Genda Chen
{"title":"A corrosion threshold-controllable sensing system of Fe-C coated long period fiber gratings for life-cycle mass loss measurement of steel bars with strain and temperature compensation","authors":"Chuanrui Guo, Genda Chen","doi":"10.12989/SSS.2021.28.4.443","DOIUrl":null,"url":null,"abstract":"In this study, a corrosion threshold-controllable sensing system of long period fiber gratings (LPFG) is developed and validated for life-cycle monitoring of steel bars in corrosive environments. Three Fe-C coated LPFG sensors with two bare LPFG sensors in LP06 and LP07 modes for strain and temperature compensation were multiplexed and deployed inside three miniature, coaxial steel tubes to measure three (long-term in years) critical mass losses through the penetration of tube walls and their corresponding (short-term in hours) corrosion rates in the life span of steel bars. The strain/temperature and mass loss measurements are based on the changes in grating period and refractive index of surrounding medium, respectively. Thermal/mechanical loading and accelerated corrosion tests were conducted to validate the functionality, sensitivity, accuracy, and robustness of the proposed sensing system. Since both the steel tube and Fe-C layer represent the material composition of steel bars in the context of corrosion, the mass loss correlation among any two of the steel tube, Fe-C layer and steel bar is independent of the test conditions such as the current density and sample length, and thus applicable to engineering practices. The outer tube can notably delay and decelerate the corrosion process of its inner steel tube due to the reduced current effect.","PeriodicalId":51155,"journal":{"name":"Smart Structures and Systems","volume":"28 1","pages":"443"},"PeriodicalIF":2.1000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Smart Structures and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.12989/SSS.2021.28.4.443","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, a corrosion threshold-controllable sensing system of long period fiber gratings (LPFG) is developed and validated for life-cycle monitoring of steel bars in corrosive environments. Three Fe-C coated LPFG sensors with two bare LPFG sensors in LP06 and LP07 modes for strain and temperature compensation were multiplexed and deployed inside three miniature, coaxial steel tubes to measure three (long-term in years) critical mass losses through the penetration of tube walls and their corresponding (short-term in hours) corrosion rates in the life span of steel bars. The strain/temperature and mass loss measurements are based on the changes in grating period and refractive index of surrounding medium, respectively. Thermal/mechanical loading and accelerated corrosion tests were conducted to validate the functionality, sensitivity, accuracy, and robustness of the proposed sensing system. Since both the steel tube and Fe-C layer represent the material composition of steel bars in the context of corrosion, the mass loss correlation among any two of the steel tube, Fe-C layer and steel bar is independent of the test conditions such as the current density and sample length, and thus applicable to engineering practices. The outer tube can notably delay and decelerate the corrosion process of its inner steel tube due to the reduced current effect.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种具有应变和温度补偿的铁碳涂层长周期光纤光栅腐蚀阈值可控传感系统
在本研究中,开发并验证了一种用于腐蚀环境中钢筋全生命周期监测的长周期光纤光栅(LPFG)腐蚀阈值可控传感系统。三个Fe-C涂层LPFG传感器和两个裸LPFG传感器在LP06和LP07模式下进行应变和温度补偿,并将其多路复用并部署在三个微型同轴钢管中,以测量穿透管壁的三个临界质量损失(长期以年为单位)及其相应的(短期以小时为单位)腐蚀速率。应变/温度和质量损失的测量分别基于光栅周期和周围介质折射率的变化。进行了热/机械载荷和加速腐蚀试验,以验证所提出的传感系统的功能、灵敏度、准确性和鲁棒性。由于钢管和Fe-C层都代表了钢筋在腐蚀情况下的材料组成,因此钢管、Fe-C层和钢筋之间的质量损失相关性与电流密度、试样长度等试验条件无关,因此适用于工程实践。由于电流效应的减小,外管可以显著延缓和减缓内管的腐蚀过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Smart Structures and Systems
Smart Structures and Systems 工程技术-工程:机械
CiteScore
6.50
自引率
8.60%
发文量
0
审稿时长
9 months
期刊介绍: An International Journal of Mechatronics, Sensors, Monitoring, Control, Diagnosis, and Management airns at providing a major publication channel for researchers in the general area of smart structures and systems. Typical subjects considered by the journal include: Sensors/Actuators(Materials/devices/ informatics/networking) Structural Health Monitoring and Control Diagnosis/Prognosis Life Cycle Engineering(planning/design/ maintenance/renewal) and related areas.
期刊最新文献
Analysis, optimization and control of an adaptive tuned vibration absorber featuring magnetoactive materials Numerical investigation on cyclic behaviour of superelastic shape memory alloy (SMA) dampers Hybrid fragility curve derivation of buildings based on post-earthquake reconnaissance data A corrosion threshold-controllable sensing system of Fe-C coated long period fiber gratings for life-cycle mass loss measurement of steel bars with strain and temperature compensation Steel dual-ring dampers: Micro-finite element modelling and validation of cyclic behavior
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1