Numerical simulation-based performance improvement of the separation of circulating tumor cells from bloodstream in a microfluidic platform by dielectrophoresis

IF 2.2 4区 工程技术 Q2 MECHANICS Korea-Australia Rheology Journal Pub Date : 2022-08-12 DOI:10.1007/s13367-022-00039-6
Ngoc-Viet Nguyen, Hoang Van Manh, Nguyen Van Hieu
{"title":"Numerical simulation-based performance improvement of the separation of circulating tumor cells from bloodstream in a microfluidic platform by dielectrophoresis","authors":"Ngoc-Viet Nguyen,&nbsp;Hoang Van Manh,&nbsp;Nguyen Van Hieu","doi":"10.1007/s13367-022-00039-6","DOIUrl":null,"url":null,"abstract":"<div><p>Circulating tumor cells (CTCs) detection has become one of the promising solutions for the early diagnosis of cancers. Thus, the separation of CTCs is of great importance in biomedical applications. In addition, microfluidic technology has been an attractive approach to the manipulation of biological cells. This study presents the parametric investigations relevant to the volumetric throughput of a microfluidic platform with the dielectrophoresis (DEP)-based cell manipulation technique for the continuous CTCs separation. A low potential voltage at an appropriate frequency was applied to slanted planar electrodes to separate CTCs from normal cells in blood samples due to mainly the cell size difference. The performance of the separation process was analyzed by evaluating the cell trajectories, purity, and recovery rates. Several inlet flow rates of buffer and cell sample fluid streams were examined. Various channel configurations with different outlet and height dimensions were also investigated to enhance the isolation of CTCs. During the simulation, the size and shape of cells were assumed as fixed-sized, solid spheres. The results showed that CTCs could be separated from blood cells, including white blood cells (WBCs), red blood cells (RBCs), and platelets (PLTs) with recovery and purity factors up to 100% at the cell sample throughput of 10 µL/min by utilizing a suitable microchannel design. The current study significantly contributes valuable insights into the design of the microchip devices to effectively and selectively isolate different cancerous cells in biofluids.</p><h3>Graphical abstract</h3>\n <figure><div><div><div><picture><source><img></source></picture></div></div></div></figure>\n </div>","PeriodicalId":683,"journal":{"name":"Korea-Australia Rheology Journal","volume":"34 4","pages":"335 - 347"},"PeriodicalIF":2.2000,"publicationDate":"2022-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korea-Australia Rheology Journal","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s13367-022-00039-6","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 3

Abstract

Circulating tumor cells (CTCs) detection has become one of the promising solutions for the early diagnosis of cancers. Thus, the separation of CTCs is of great importance in biomedical applications. In addition, microfluidic technology has been an attractive approach to the manipulation of biological cells. This study presents the parametric investigations relevant to the volumetric throughput of a microfluidic platform with the dielectrophoresis (DEP)-based cell manipulation technique for the continuous CTCs separation. A low potential voltage at an appropriate frequency was applied to slanted planar electrodes to separate CTCs from normal cells in blood samples due to mainly the cell size difference. The performance of the separation process was analyzed by evaluating the cell trajectories, purity, and recovery rates. Several inlet flow rates of buffer and cell sample fluid streams were examined. Various channel configurations with different outlet and height dimensions were also investigated to enhance the isolation of CTCs. During the simulation, the size and shape of cells were assumed as fixed-sized, solid spheres. The results showed that CTCs could be separated from blood cells, including white blood cells (WBCs), red blood cells (RBCs), and platelets (PLTs) with recovery and purity factors up to 100% at the cell sample throughput of 10 µL/min by utilizing a suitable microchannel design. The current study significantly contributes valuable insights into the design of the microchip devices to effectively and selectively isolate different cancerous cells in biofluids.

Graphical abstract

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于数值模拟的微流控平台介质电泳分离循环肿瘤细胞的性能改进
循环肿瘤细胞(CTCs)检测已成为癌症早期诊断的重要手段之一。因此,ctc的分离在生物医学应用中具有重要意义。此外,微流体技术已经成为操纵生物细胞的一种有吸引力的方法。本研究采用基于介质电泳(DEP)的细胞操作技术,对微流控平台连续分离ctc的体积通量进行了参数化研究。在倾斜平面电极上施加适当频率的低电位电压,将血液样品中的ctc与正常细胞分离,主要是由于细胞大小的差异。通过评估细胞轨迹、纯度和回收率来分析分离过程的性能。研究了缓冲液和细胞样品流的几种进口流速。还研究了不同出口和高度尺寸的通道配置,以提高ctc的隔离。在模拟过程中,假设细胞的大小和形状为固定大小的固体球体。结果表明,采用合适的微通道设计,在10 μ L/min的细胞样品通量下,ctc可从白细胞(wbc)、红细胞(rbc)和血小板(PLTs)等血细胞中分离,回收率和纯度可达100%。目前的研究为微芯片设备的设计提供了有价值的见解,以有效和选择性地分离生物体液中的不同癌细胞。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Korea-Australia Rheology Journal
Korea-Australia Rheology Journal 工程技术-高分子科学
CiteScore
2.80
自引率
0.00%
发文量
28
审稿时长
>12 weeks
期刊介绍: The Korea-Australia Rheology Journal is devoted to fundamental and applied research with immediate or potential value in rheology, covering the science of the deformation and flow of materials. Emphases are placed on experimental and numerical advances in the areas of complex fluids. The journal offers insight into characterization and understanding of technologically important materials with a wide range of practical applications.
期刊最新文献
Effect of stirring time on viscoelastic properties of liquid gallium-oxide amalgams Study of the impurity dissolution kinetics, rheological characterization, and hydrodynamic aspects during the bioleaching of iron ore pulp in a bioreactor Construction of self-stacking nanostructure with MXene and CNT through dopamine polymerization The rheological behaviors, aging properties, and thermal stability of chain extended poly(butylene adipate-co-terephthalate) The computational method with the deformed mesh interfaces for an incompressible layer indentation by rigid indenters with arbitrary axisymmetric smooth profiles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1