Influence of different ligation methods on force and moment generation in a simulated condition of the maxillary crowded anterior dentition with linguo-version and rotation.
Sunmin Kim, I. Yonemitsu, H. Takemura, Kunio Shimoda, K. Suga, K. Soga, T. Ono, M. Uo
{"title":"Influence of different ligation methods on force and moment generation in a simulated condition of the maxillary crowded anterior dentition with linguo-version and rotation.","authors":"Sunmin Kim, I. Yonemitsu, H. Takemura, Kunio Shimoda, K. Suga, K. Soga, T. Ono, M. Uo","doi":"10.3233/bme-211288","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nMost orthodontic cases consist of varying degrees of crowding. To manage crowded dentitions, nickel-titanium archwires with various ligation methods are often used.\n\n\nOBJECTIVE\nWe aimed to investigate the effect of different ligation methods with respect to force and moment and suggest the efficient ligation method for treating rotation and displacement simultaneously.\n\n\nMETHODS\nWe built a model that simulated the three anterior teeth of the maxilla. The teeth on the two ends were fixed, and the middle tooth was set in several different positions by manipulating the amount of displacement in bucco-lingual direction and rotation angle. The measurements were taken with three different ligation methods of self-ligation (SL), elastomeric o-ring ligation on both side wings (EB), and on one side wings (EO).\n\n\nRESULTS\nThe magnitude of linguo-buccal force exceeded the standard optimal force in each condition examined and was significantly larger in EB than in other ligation methods. Moreover, the magnitude of moment generation with SL was suitable in the 0.0 mm linguo-version, whereas it was suitable with EO in the linguo-version ranging 1.0-3.0 mm.\n\n\nCONCLUSIONS\nThe ligation method significantly affected the force and moment. SL and EO are recommended in dentitions with light and deep lingual displacements, respectively.","PeriodicalId":9109,"journal":{"name":"Bio-medical materials and engineering","volume":" ","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2022-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bio-medical materials and engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/bme-211288","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND
Most orthodontic cases consist of varying degrees of crowding. To manage crowded dentitions, nickel-titanium archwires with various ligation methods are often used.
OBJECTIVE
We aimed to investigate the effect of different ligation methods with respect to force and moment and suggest the efficient ligation method for treating rotation and displacement simultaneously.
METHODS
We built a model that simulated the three anterior teeth of the maxilla. The teeth on the two ends were fixed, and the middle tooth was set in several different positions by manipulating the amount of displacement in bucco-lingual direction and rotation angle. The measurements were taken with three different ligation methods of self-ligation (SL), elastomeric o-ring ligation on both side wings (EB), and on one side wings (EO).
RESULTS
The magnitude of linguo-buccal force exceeded the standard optimal force in each condition examined and was significantly larger in EB than in other ligation methods. Moreover, the magnitude of moment generation with SL was suitable in the 0.0 mm linguo-version, whereas it was suitable with EO in the linguo-version ranging 1.0-3.0 mm.
CONCLUSIONS
The ligation method significantly affected the force and moment. SL and EO are recommended in dentitions with light and deep lingual displacements, respectively.
期刊介绍:
The aim of Bio-Medical Materials and Engineering is to promote the welfare of humans and to help them keep healthy. This international journal is an interdisciplinary journal that publishes original research papers, review articles and brief notes on materials and engineering for biological and medical systems. Articles in this peer-reviewed journal cover a wide range of topics, including, but not limited to: Engineering as applied to improving diagnosis, therapy, and prevention of disease and injury, and better substitutes for damaged or disabled human organs; Studies of biomaterial interactions with the human body, bio-compatibility, interfacial and interaction problems; Biomechanical behavior under biological and/or medical conditions; Mechanical and biological properties of membrane biomaterials; Cellular and tissue engineering, physiological, biophysical, biochemical bioengineering aspects; Implant failure fields and degradation of implants. Biomimetics engineering and materials including system analysis as supporter for aged people and as rehabilitation; Bioengineering and materials technology as applied to the decontamination against environmental problems; Biosensors, bioreactors, bioprocess instrumentation and control system; Application to food engineering; Standardization problems on biomaterials and related products; Assessment of reliability and safety of biomedical materials and man-machine systems; and Product liability of biomaterials and related products.