{"title":"Impact of 6MV and 10MV flattened and flattening filter free beam in whole brain radiotherapy – A treatment planning study.","authors":"Tamilarsu Suresh, Saminathan Madeswaran","doi":"10.22038/IJMP.2020.46947.1740","DOIUrl":null,"url":null,"abstract":"Introduction: To study the impact of 6MV and 10MV flattened beam (FB) and flattening filter free beam (FFF) in whole brain radiotherapy (WBRT) by using volumetric arc therapy (VMAT).Materials and Methods: Twenty whole brain radiotherapy patients were selected randomly and the dose prescription was 30Gy, which is delivered in 10 fractions. Planning target volume (PTV) and organ at risk (OAR’S) were contoured. The four VMAT plans, like 6MV FB, 6MV FFF, 10MV FB and 10MV FFF were generated for each patient in Eclipse Treatment Planning system. PTV coverage, OAR’s doses and delivery monitoring units (MU) were noted.Results: The 6MV FB and FFF beam plan were statistically significant (p","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2020.46947.1740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: To study the impact of 6MV and 10MV flattened beam (FB) and flattening filter free beam (FFF) in whole brain radiotherapy (WBRT) by using volumetric arc therapy (VMAT).Materials and Methods: Twenty whole brain radiotherapy patients were selected randomly and the dose prescription was 30Gy, which is delivered in 10 fractions. Planning target volume (PTV) and organ at risk (OAR’S) were contoured. The four VMAT plans, like 6MV FB, 6MV FFF, 10MV FB and 10MV FFF were generated for each patient in Eclipse Treatment Planning system. PTV coverage, OAR’s doses and delivery monitoring units (MU) were noted.Results: The 6MV FB and FFF beam plan were statistically significant (p
期刊介绍:
Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.