Prospective application of virtual touch tissue imaging quantification in the diagnosis of initial polymyositis

Qi Xu, Liu Zezheng, Qiqi Wen, Zhangqian Zhu, Su-rong Lin
{"title":"Prospective application of virtual touch tissue imaging quantification in the diagnosis of initial polymyositis","authors":"Qi Xu, Liu Zezheng, Qiqi Wen, Zhangqian Zhu, Su-rong Lin","doi":"10.3760/CMA.J.ISSN.1004-4477.2020.01.011","DOIUrl":null,"url":null,"abstract":"Objective \nTo explore the application value of virtual touch tissue imaging quantification(VTIQ) technology in initial polymyositis(PM). \n \n \nMethods \nSixteen PM patients collected from February 2016 to March 2019 in Wenzhou People′s Hospital were selected as PM group, and 33 healthy subjects as healthy control group. After gray and color Doppler ultrasound, the shear wave velocity(SWV) values of target muscle and control muscle in the same side of affected limb were measured by VTIQ technique. Maximum velocity(Vmax) and minimum velocity(Vmin) were measured, average velocity(Vmean) and standard deviation(SD) were calculated, and compared between the two groups. SWV difference and ratio between target muscle and control muscle were calculated, and creatine kinase(CK) was detected in the same day. \n \n \nResults \nPart of PM patients had abnormal ultrasonographic manifestations of full muscle shape (31.25%), increased or decreased echo of muscle bundles (56.25%), blurred muscle texture (25.00%) and increased blood flow signals (37.50%). There were significant differences in Vmin, SD, and Vmax difference, Vmin difference, Vmean difference, and Vmax ratio, Vmin ratio, and Vmean ratio between PM group and healthy control group (all P<0.01). The ROC curve analysis showed that the diagnostic efficiency of Vmin was lower than those of Vmin difference and Vmean difference, Vmin ratio and Vmean ratio with very close diagnostic efficiencies of the latter four parameters. The correlation analysis showed that Vmin difference and Vmean difference were moderately correlated with CK value(r=0.512, 0.601; all P<0.05). \n \n \nConclusions \nReduced VTIQ values or relative reduction of VTIQ values compared with other non-involved muscles are the manifestations of initial PM, VTIQ have certain diagnostic efficacy for initial PM. \n \n \nKey words: \nVirtual touch tissue imaging quantification; Polymyositis; Applied research","PeriodicalId":10224,"journal":{"name":"中华超声影像学杂志","volume":"29 1","pages":"60-65"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华超声影像学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2020.01.011","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To explore the application value of virtual touch tissue imaging quantification(VTIQ) technology in initial polymyositis(PM). Methods Sixteen PM patients collected from February 2016 to March 2019 in Wenzhou People′s Hospital were selected as PM group, and 33 healthy subjects as healthy control group. After gray and color Doppler ultrasound, the shear wave velocity(SWV) values of target muscle and control muscle in the same side of affected limb were measured by VTIQ technique. Maximum velocity(Vmax) and minimum velocity(Vmin) were measured, average velocity(Vmean) and standard deviation(SD) were calculated, and compared between the two groups. SWV difference and ratio between target muscle and control muscle were calculated, and creatine kinase(CK) was detected in the same day. Results Part of PM patients had abnormal ultrasonographic manifestations of full muscle shape (31.25%), increased or decreased echo of muscle bundles (56.25%), blurred muscle texture (25.00%) and increased blood flow signals (37.50%). There were significant differences in Vmin, SD, and Vmax difference, Vmin difference, Vmean difference, and Vmax ratio, Vmin ratio, and Vmean ratio between PM group and healthy control group (all P<0.01). The ROC curve analysis showed that the diagnostic efficiency of Vmin was lower than those of Vmin difference and Vmean difference, Vmin ratio and Vmean ratio with very close diagnostic efficiencies of the latter four parameters. The correlation analysis showed that Vmin difference and Vmean difference were moderately correlated with CK value(r=0.512, 0.601; all P<0.05). Conclusions Reduced VTIQ values or relative reduction of VTIQ values compared with other non-involved muscles are the manifestations of initial PM, VTIQ have certain diagnostic efficacy for initial PM. Key words: Virtual touch tissue imaging quantification; Polymyositis; Applied research
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
虚拟触摸组织成像量化在早期多发性肌炎诊断中的应用前景
目的探讨虚拟触摸组织成像量化(VTIQ)技术在原发性多发性肌炎(PM)中的应用价值。方法选取2016年2月至2019年3月在温州市人民医院就诊的PM患者16例作为PM组,正常人33例作为健康对照组。经灰色和彩色多普勒超声后,采用VTIQ技术测量患肢同侧靶肌和对照肌的横波速度(SWV)值。测定两组间最大流速(Vmax)和最小流速(Vmin),计算平均流速(Vmean)和标准差(SD),并进行比较。计算靶肌与对照肌的SWV差值及比值,并在同一天检测肌酸激酶(CK)。结果部分PM患者超声异常表现为肌肉形态完整(31.25%),肌束回声增高或降低(56.25%),肌肉纹理模糊(25.00%),血流信号增高(37.50%)。PM组与健康对照组Vmin、SD、Vmax差异、Vmin差异、Vmean差异、Vmax比值、Vmin比值、Vmean比值差异均有统计学意义(P<0.01)。ROC曲线分析显示,Vmin的诊断效率低于Vmin差值和Vmean差值、Vmin比和Vmean比,后4个参数的诊断效率非常接近。相关分析显示,Vmin差异和Vmean差异与CK值呈中度相关(r=0.512, 0.601;所有P < 0.05)。结论VTIQ值降低或与其他未受累肌肉相比VTIQ值相对降低是原发性PM的表现,VTIQ对原发性PM有一定的诊断作用。关键词:虚拟触摸组织成像定量;多肌炎;应用研究
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中华超声影像学杂志
中华超声影像学杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.80
自引率
0.00%
发文量
9126
期刊介绍:
期刊最新文献
A case of breakthrough infection with SARS-CoV-2 Delta derivative and reinfection with Omicron variant in a fully vaccinated health care professional. Ultrasound-guided pathological sampling of cadaver lung tissue in cases of COVID-19 Ultrasound-guided post-mortem tissue sampling in the autopsy of COVID-19 cases: a pilot study The clinical value of ultrasound in the assessment of the severity of COVID-19 Study of positioning of fetal conus medullaris by detecting atlanto-axial intervertebral space with three-dimensional ultrasound
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1