The effect of silver-containing sorbent on red blood cells during hemosorption: an in vitro study

Q4 Biochemistry, Genetics and Molecular Biology Sibirskii nauchnyi meditsinskii zhurnal Pub Date : 2022-10-27 DOI:10.18699/ssmj20220503
L. N. Rachkovskaya, A. Smagin, V. Nimaev, A. Demura, E. Rachkovsky, E. Yastrebova, V. Maltsev, M. Korolev, A. Letyagin
{"title":"The effect of silver-containing sorbent on red blood cells during hemosorption: an in vitro study","authors":"L. N. Rachkovskaya, A. Smagin, V. Nimaev, A. Demura, E. Rachkovsky, E. Yastrebova, V. Maltsev, M. Korolev, A. Letyagin","doi":"10.18699/ssmj20220503","DOIUrl":null,"url":null,"abstract":"The aim of the study was to investigate the influence of the original porous silver–containing sorbent on the morphofunctional parameters of red blood cells during in vitro hemoperfusion. Material and methods. Donor blood was perfused through glass columns filled with a sorbent based on porous aluminum oxide, polydimethylsiloxane and silver nanoclusters and a sorbent without silver. The effect of a silver-containing sorbent on the change in morphofunctional parameters of red blood cells after perfusion through sorbents was determined by scanning flow cytometry. Results and their discussion. Due to the uniformity of the distribution of silver (0.1 %) over the sorbent granules, the parameters of the porous structure – the specific surface area and pore volume – practically do not change compared to the sorbent without silver. Morphological parameters of original donor blood and after hemoperfusion are within the norm. The functional parameters are also normal, although the introduction of silver in to the sorbent slightly increases the number of active band 3 (B3) proteins on erythrocyte membranes, both in comparison with the donor red cell mass as a control and in comparison with the sorbent without silver. There is also an increase in the ultimate extensibility of the erythrocyte membrane compared to the original blood (2.2 times) and the sorbent without silver (1.4 times). Conclusions. A sorbent modified with silver and a sorbent without silver does not have a damaging toxic effect on the morphofunctional parameters of blood under perfusion conditions. The mechanisms affecting the indicators of the ultimate extensibility of the erythrocyte membrane after blood perfusion through a silver-containing sorbent require further research.","PeriodicalId":33781,"journal":{"name":"Sibirskii nauchnyi meditsinskii zhurnal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sibirskii nauchnyi meditsinskii zhurnal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18699/ssmj20220503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study was to investigate the influence of the original porous silver–containing sorbent on the morphofunctional parameters of red blood cells during in vitro hemoperfusion. Material and methods. Donor blood was perfused through glass columns filled with a sorbent based on porous aluminum oxide, polydimethylsiloxane and silver nanoclusters and a sorbent without silver. The effect of a silver-containing sorbent on the change in morphofunctional parameters of red blood cells after perfusion through sorbents was determined by scanning flow cytometry. Results and their discussion. Due to the uniformity of the distribution of silver (0.1 %) over the sorbent granules, the parameters of the porous structure – the specific surface area and pore volume – practically do not change compared to the sorbent without silver. Morphological parameters of original donor blood and after hemoperfusion are within the norm. The functional parameters are also normal, although the introduction of silver in to the sorbent slightly increases the number of active band 3 (B3) proteins on erythrocyte membranes, both in comparison with the donor red cell mass as a control and in comparison with the sorbent without silver. There is also an increase in the ultimate extensibility of the erythrocyte membrane compared to the original blood (2.2 times) and the sorbent without silver (1.4 times). Conclusions. A sorbent modified with silver and a sorbent without silver does not have a damaging toxic effect on the morphofunctional parameters of blood under perfusion conditions. The mechanisms affecting the indicators of the ultimate extensibility of the erythrocyte membrane after blood perfusion through a silver-containing sorbent require further research.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
含银吸附剂在血液吸收过程中对红细胞影响的体外研究
本研究旨在探讨原多孔含银吸附剂对体外血液灌流过程中红细胞形态功能参数的影响。材料和方法。供体血液通过玻璃柱灌注,玻璃柱中填充了一种基于多孔氧化铝、聚二甲基硅氧烷和银纳米团簇的吸附剂和一种不含银的吸附剂。采用扫描流式细胞术研究含银吸附剂对红细胞灌注后形态功能参数变化的影响。结果和讨论。由于银的均匀分布(0.1%)在吸附剂颗粒上,与没有银的吸附剂相比,多孔结构的参数-比表面积和孔体积-实际上没有变化。原供血及血液灌流后的形态学参数均在正常范围内。功能参数也正常,尽管引入银的吸附剂略微增加了红细胞膜上活性带3 (B3)蛋白的数量,无论是与供体红细胞群作为对照,还是与不含银的吸附剂相比。与原始血液(2.2倍)和无银吸附剂(1.4倍)相比,红细胞膜的最终延伸性也有所增加。结论。在灌注条件下,用银修饰的吸附剂和不含银的吸附剂对血液的形态功能参数没有破坏性的毒性作用。含银吸附剂血液灌注后影响红细胞膜最终伸长指标的机制有待进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
54
审稿时长
12 weeks
期刊最新文献
The relationship between methylation of tumor suppressor genes <i>APC</i>, <i>GSTP1</i>, <i>RASSF1A</i> and content of prostate-specific antigen- associated markers in prostate cancer diagnosis Changes in the <i>MIR-143</i. gene methylation pattern in the tumor tissue of the diffuse large B-cell lymphoma Some indicators of nutritional security of children with restrictive types of nutrition Influence of alcohol consumption on the levels of surfactant proteins SP-A and SP-D in blood in men and women in Novosibirsk Association of vitamin D deficiency and preterm birth
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1