Detailed CT dosimetry in Moroccan hospitals as a preparation for the development of national DRL’s.

Q3 Health Professions Iranian Journal of Medical Physics Pub Date : 2021-09-08 DOI:10.22038/IJMP.2021.56076.1934
Imane Ou-saada, S. Douama, Youssef Bouzekraoui, Hilde Bosmann, L. Cockmartin, M. Campoleoni, Oumnia Ou-saada, Rachid Errifai, L. B. Drissi, F. Bentayeb
{"title":"Detailed CT dosimetry in Moroccan hospitals as a preparation for the development of national DRL’s.","authors":"Imane Ou-saada, S. Douama, Youssef Bouzekraoui, Hilde Bosmann, L. Cockmartin, M. Campoleoni, Oumnia Ou-saada, Rachid Errifai, L. B. Drissi, F. Bentayeb","doi":"10.22038/IJMP.2021.56076.1934","DOIUrl":null,"url":null,"abstract":"Purpose: The aim of this study is to estimate local DRL values for computed tomography (CT) procedures, corresponding to Head, Chest, and Abdomen-Pelvis examinations (single acquisition), in Moroccan hospitals.Methods: A total of 1917 diagnostic CT examinations were included in this study. Firstly, we analyzed the CT dose indicators CTDIvol and DLP of all the examinations collected. Although we have proposed local diagnostic reference levels just for: head, thorax, abdomen-pelvis, due to the lack of data for the other examinations. Furthermore, we calculated the effective dose for chest examination using CT-expo software to estimate effective and organ dose for chest CT.The results: showed that the estimated local DRLs using CTDIvol are 48 mGy, 14 mGy, and 12 mGy for head, chest, and abdomen-pelvis respectively, and 986 mGy.cm, 496 mGy.cm, and 651 mGy.cm for DLP, respectively.Conclusion: This work establishes local DRLs for CTDIvol and total DLP for head, chest, and abdomen-pelvis procedures and proposes chest effective doses for adult patients. The study shows that the results are conforming to the literature.","PeriodicalId":14613,"journal":{"name":"Iranian Journal of Medical Physics","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/IJMP.2021.56076.1934","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study is to estimate local DRL values for computed tomography (CT) procedures, corresponding to Head, Chest, and Abdomen-Pelvis examinations (single acquisition), in Moroccan hospitals.Methods: A total of 1917 diagnostic CT examinations were included in this study. Firstly, we analyzed the CT dose indicators CTDIvol and DLP of all the examinations collected. Although we have proposed local diagnostic reference levels just for: head, thorax, abdomen-pelvis, due to the lack of data for the other examinations. Furthermore, we calculated the effective dose for chest examination using CT-expo software to estimate effective and organ dose for chest CT.The results: showed that the estimated local DRLs using CTDIvol are 48 mGy, 14 mGy, and 12 mGy for head, chest, and abdomen-pelvis respectively, and 986 mGy.cm, 496 mGy.cm, and 651 mGy.cm for DLP, respectively.Conclusion: This work establishes local DRLs for CTDIvol and total DLP for head, chest, and abdomen-pelvis procedures and proposes chest effective doses for adult patients. The study shows that the results are conforming to the literature.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在摩洛哥医院进行详细的CT剂量测定,为国家DRL的发展做准备。
目的:本研究的目的是估计摩洛哥医院的计算机断层扫描(CT)程序的局部DRL值,对应于头部、胸部和腹部-骨盆检查(单采集)。方法:共收集1917例诊断性CT检查。首先,我们对收集到的所有检查的CT剂量指标CTDIvol和DLP进行分析。虽然由于缺乏其他检查的数据,我们只提出了局部诊断参考水平:头部,胸部,腹部-骨盆。此外,我们使用CT-expo软件计算胸部检查的有效剂量,以估计胸部CT的有效剂量和器官剂量。结果表明:CTDIvol对头部、胸部和腹骨盆的局部DRLs分别为48 mGy、14 mGy和12 mGy,分别为986 mGy。厘米,496mgy。cm和651mgy。DLP分别为cm。结论:本工作建立了CTDIvol的局部drl和头部、胸部和腹部-骨盆手术的总DLP,并提出了成人患者的胸部有效剂量。研究结果与文献一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Iranian Journal of Medical Physics
Iranian Journal of Medical Physics Health Professions-Radiological and Ultrasound Technology
CiteScore
1.00
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊介绍: Iranian Journal of Medical Physics (IJMP) is the official scientific bimonthly publication of the Iranian Association of Medical Physicists. IJMP is an international and multidisciplinary journal, peer review, free of charge publication and open access. This journal devoted to publish Original Papers, Review Articles, Short Communications, Technical Notes, Editorial and Letters to the Editor in the field of “Medical Physics” involving both basic and clinical research. Submissions of manuscript from all countries are welcome and will be reviewed by at least two expert reviewers.
期刊最新文献
Secondary cancer risk after radiotherapy of seminoma stage one The effect of cobalt oxide nanoparticles on improving the quality of CT and PET scan medical imaging Scatter radiation absorbed dose distribution in coronary angiography: A measurement based study Evaluation of Low-Dose 3D skull CT images in craniosynostosis Left-sided Breast Cancer Radiotherapy and Risk of Heart Diseases: with Considering Baseline Risk of Heart Diseases
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1