A. S. Wibowo, E. Cahyono, R. S. Iswari, Kholik Al Amin, M. Jannah
{"title":"COMPARISON OF THE EFFECTIVENESS OF RADIATION SHIELD WALL BETWEEN LEAD-LAYERS AND PLASTERING BRICK-LAYERS","authors":"A. S. Wibowo, E. Cahyono, R. S. Iswari, Kholik Al Amin, M. Jannah","doi":"10.31983/jrk.v11i2.9307","DOIUrl":null,"url":null,"abstract":"The rate of exposure to X-ray radiation on the radiation shielding wall at the Laboratory 3 of Radiology Study Program Purwokerto Diploma Three Program has been analyzed, to find out the difference in the effectiveness of the radiation shielding wall between a 10 cm thick Lead (2 mm) coated partition and a 28 cm thick stucco brick wall. Measurements were made using a radiation source, namely a mobile unit X-ray machine with a Fluke survey meter radiation measuring instrument. Measurement of the rate of exposure to X-ray radiation is carried out by adjusting the distance of the radiation source with the radiation shield wall from 100 cm, 150 cm and 200 cm and taken from 5 measurement points that represent the radiation shield wall. The measurement results show that measurement point C produces the highest radiation exposure rate and measurement point A produces the lowest radiation exposure rate for Do and D. There is a radiation exposure rate of more than 1 μSv/Hr after passing through a 10 cm thick Lead-coated partition wall (2 mm) at a distance of 100 cm to 150 cm. Radiation shielding walls of walls covered with stucco bricks with a thickness of 28 cm were more effective than partitions covered with lead (2 mm) with a thickness of 10 cm. It is necessary to pay attention to aspects of radiation protection, the use of a mobile unit X-ray machine in placing the X-ray tube in the direction of the X-ray tube and, the radiation source distance of at least 2 meters from the lead-coated partition radiation wall.","PeriodicalId":52993,"journal":{"name":"Jurnal Riset Kesehatan","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Riset Kesehatan","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31983/jrk.v11i2.9307","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The rate of exposure to X-ray radiation on the radiation shielding wall at the Laboratory 3 of Radiology Study Program Purwokerto Diploma Three Program has been analyzed, to find out the difference in the effectiveness of the radiation shielding wall between a 10 cm thick Lead (2 mm) coated partition and a 28 cm thick stucco brick wall. Measurements were made using a radiation source, namely a mobile unit X-ray machine with a Fluke survey meter radiation measuring instrument. Measurement of the rate of exposure to X-ray radiation is carried out by adjusting the distance of the radiation source with the radiation shield wall from 100 cm, 150 cm and 200 cm and taken from 5 measurement points that represent the radiation shield wall. The measurement results show that measurement point C produces the highest radiation exposure rate and measurement point A produces the lowest radiation exposure rate for Do and D. There is a radiation exposure rate of more than 1 μSv/Hr after passing through a 10 cm thick Lead-coated partition wall (2 mm) at a distance of 100 cm to 150 cm. Radiation shielding walls of walls covered with stucco bricks with a thickness of 28 cm were more effective than partitions covered with lead (2 mm) with a thickness of 10 cm. It is necessary to pay attention to aspects of radiation protection, the use of a mobile unit X-ray machine in placing the X-ray tube in the direction of the X-ray tube and, the radiation source distance of at least 2 meters from the lead-coated partition radiation wall.