Performance assessment and validation of inverter control current controllers in reduced sensor maximum power point tracking based photovoltaic-grid tied system
Moushumi Patowary, Hassan Haes Alhelou, Gayadhar Panda
{"title":"Performance assessment and validation of inverter control current controllers in reduced sensor maximum power point tracking based photovoltaic-grid tied system","authors":"Moushumi Patowary, Hassan Haes Alhelou, Gayadhar Panda","doi":"10.1049/esi2.12076","DOIUrl":null,"url":null,"abstract":"<p>A relative assessment on conventional and adaptive current controllers used in reduced sensor-maximum power point tracking (MPPT) based photovoltaic (PV)-grid tied inverter systems for the improvement of system power quality is suggested. The steady-state and transients errors produced in the conventional PI and proportional resonant controllers, which are used to generate the references, can be fixed by using an intelligent ADALINE-LMS adaptive controller; moreover, it helps in reducing the %THD (total harmonic distortion) level measured at different power zones. Also, to track the maximum PV power, which is further integrated to DC-bus, a reduced sensor-based technology is added into the circuit that sidesteps the problem of tracking local MPP instead of global MPP and the drawbacks of using current sensors. The use of a reduced sensor-based MPPT controller confirms extraction of maximum PV power and it guarantees a constant DC-link voltage under all the possible test conditions. The overall control architectures and system performances, which are tested under different system dynamics, are validated through MATLAB/Simulink as well as experimental findings obtained using the dSPACE RTI 1202 interfacing kit. These experimental results confirm that the adaptive control technique used in reduced sensor-MPPT based PV-grid tied inverter systems performs unbeatably with balanced load and grid voltages, less harmonics, quick response time etc. under the operation of linear, non-linear and transient loads, whereas, conventional controllers are best only for the linear loads.</p>","PeriodicalId":33288,"journal":{"name":"IET Energy Systems Integration","volume":"4 4","pages":"505-517"},"PeriodicalIF":1.6000,"publicationDate":"2022-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/esi2.12076","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Energy Systems Integration","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/esi2.12076","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0
Abstract
A relative assessment on conventional and adaptive current controllers used in reduced sensor-maximum power point tracking (MPPT) based photovoltaic (PV)-grid tied inverter systems for the improvement of system power quality is suggested. The steady-state and transients errors produced in the conventional PI and proportional resonant controllers, which are used to generate the references, can be fixed by using an intelligent ADALINE-LMS adaptive controller; moreover, it helps in reducing the %THD (total harmonic distortion) level measured at different power zones. Also, to track the maximum PV power, which is further integrated to DC-bus, a reduced sensor-based technology is added into the circuit that sidesteps the problem of tracking local MPP instead of global MPP and the drawbacks of using current sensors. The use of a reduced sensor-based MPPT controller confirms extraction of maximum PV power and it guarantees a constant DC-link voltage under all the possible test conditions. The overall control architectures and system performances, which are tested under different system dynamics, are validated through MATLAB/Simulink as well as experimental findings obtained using the dSPACE RTI 1202 interfacing kit. These experimental results confirm that the adaptive control technique used in reduced sensor-MPPT based PV-grid tied inverter systems performs unbeatably with balanced load and grid voltages, less harmonics, quick response time etc. under the operation of linear, non-linear and transient loads, whereas, conventional controllers are best only for the linear loads.