Huan Liu, Xiaodi Chen, Zihao Wang, Y. Liu, Cuiyuan Liang, Ming Zhu, Dianpeng Qi
{"title":"Development of soft dry electrodes: from materials to structure design","authors":"Huan Liu, Xiaodi Chen, Zihao Wang, Y. Liu, Cuiyuan Liang, Ming Zhu, Dianpeng Qi","doi":"10.20517/ss.2023.16","DOIUrl":null,"url":null,"abstract":"Bioelectric signals reflect our daily physiological activities, which can be recorded in the form of electroencephalography, electrocardiography, electromyography, etc. The traditional Ag/AgCl wet electrode is the gold standard for clinical monitoring of bioelectrical signals at present, while complicated preparation and gel evaporation limit its long-term application. Therefore, it is meaningful to research dry electrodes without conductive paste or additional adhesives. Unfortunately, the high interface impedance between electrodes and skin is a fatal defect of dry electrodes, which leads to excessive noise levels and poor signal quality. Consequently, more efforts are required to achieve conformal contact between dry electrodes and skin to reduce the contact impedance. From this perspective, we review the recent progress in capacitive electrodes, invasive microneedle electrodes, and common-contact dry electrodes. Material selection and structural design to obtain conformal contact are highlighted. Finally, we propose the future development direction of dry electrodes.","PeriodicalId":74837,"journal":{"name":"Soft science","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Soft science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20517/ss.2023.16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Bioelectric signals reflect our daily physiological activities, which can be recorded in the form of electroencephalography, electrocardiography, electromyography, etc. The traditional Ag/AgCl wet electrode is the gold standard for clinical monitoring of bioelectrical signals at present, while complicated preparation and gel evaporation limit its long-term application. Therefore, it is meaningful to research dry electrodes without conductive paste or additional adhesives. Unfortunately, the high interface impedance between electrodes and skin is a fatal defect of dry electrodes, which leads to excessive noise levels and poor signal quality. Consequently, more efforts are required to achieve conformal contact between dry electrodes and skin to reduce the contact impedance. From this perspective, we review the recent progress in capacitive electrodes, invasive microneedle electrodes, and common-contact dry electrodes. Material selection and structural design to obtain conformal contact are highlighted. Finally, we propose the future development direction of dry electrodes.