Tapered substrate thickness to enhance the performance of piezoelectric energy harvester

IF 0.3 Q4 MATERIALS SCIENCE, MULTIDISCIPLINARY Nanomaterials and Energy Pub Date : 2022-12-01 DOI:10.1680/jnaen.22.00038
Ashutosh Anand, Manish Kumar
{"title":"Tapered substrate thickness to enhance the performance of piezoelectric energy harvester","authors":"Ashutosh Anand, Manish Kumar","doi":"10.1680/jnaen.22.00038","DOIUrl":null,"url":null,"abstract":"In this paper, the improvement of the performance of the piezoelectric (PZ) cantilever beam using the non-uniform substrate thickness has been presented. This reduces the resonant frequency, improves stress distribution and generates more output voltage and power. Both analytical and finite element method (FEM) analyses have been performed to investigate the effect of tapered substrate thickness on the PZ cantilever beam. The tapered substrate thickness has been used in rectangular and trapezoidal cantilever structures. All the designed cantilever structures have the same fabrication area, and their performance has been evaluated and compared using an excitation acceleration of 1g (9.8 m/s2). The tapered-down trapezoidal cantilever can achieve the minimum resonant frequency of 62.41 Hz, which is 48.83 % less than the resonant frequency of the uniform rectangular cantilever beam. The output peak voltage and average power of the proposed tapered-down trapezoidal cantilever beam are 12.36 V and 21 µW, respectively, which are improved by 44 % and 74.48 %, respectively to the uniform rectangular cantilever structure.","PeriodicalId":44365,"journal":{"name":"Nanomaterials and Energy","volume":" ","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nanomaterials and Energy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1680/jnaen.22.00038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, the improvement of the performance of the piezoelectric (PZ) cantilever beam using the non-uniform substrate thickness has been presented. This reduces the resonant frequency, improves stress distribution and generates more output voltage and power. Both analytical and finite element method (FEM) analyses have been performed to investigate the effect of tapered substrate thickness on the PZ cantilever beam. The tapered substrate thickness has been used in rectangular and trapezoidal cantilever structures. All the designed cantilever structures have the same fabrication area, and their performance has been evaluated and compared using an excitation acceleration of 1g (9.8 m/s2). The tapered-down trapezoidal cantilever can achieve the minimum resonant frequency of 62.41 Hz, which is 48.83 % less than the resonant frequency of the uniform rectangular cantilever beam. The output peak voltage and average power of the proposed tapered-down trapezoidal cantilever beam are 12.36 V and 21 µW, respectively, which are improved by 44 % and 74.48 %, respectively to the uniform rectangular cantilever structure.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
锥形基板厚度可提高压电能量采集器的性能
本文介绍了利用非均匀衬底厚度改善压电悬臂梁性能的方法。这降低了谐振频率,改善了应力分布,并产生了更多的输出电压和功率。本文采用解析法和有限元法研究了锥形基底厚度对PZ悬臂梁的影响。锥形衬底厚度已用于矩形和梯形悬臂结构。所有设计的悬臂结构具有相同的制造面积,并在激励加速度为1g (9.8 m/s2)的情况下对其性能进行了评估和比较。锥形梯形悬臂梁的最小谐振频率为62.41 Hz,比均匀矩形悬臂梁的谐振频率低48.83%。梯形悬臂梁的输出峰值电压和平均功率分别为12.36 V和21µW,比均匀矩形悬臂梁结构分别提高了44%和74.48%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Nanomaterials and Energy
Nanomaterials and Energy MATERIALS SCIENCE, MULTIDISCIPLINARY-
CiteScore
2.10
自引率
0.00%
发文量
2
期刊最新文献
Study on particle size and field effect with sp2/sp3 ratio of hydrogenated diamond-like carbon Recycling of HIPS and multilayer films with SEBS based additives One pot synthesis of nano EMD for effective adsorption of toxic dyes Preparation of acid-sensitive polymeric oncology drug carriers and analysis of their efficacy Numerical investigation of Cs2AgBiBr6 double perovskite solar cell with optimized performances
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1