{"title":"Post-fire investigation on the mechanical properties and physical characteristics of fibre-reinforced geopolymer concrete","authors":"Vijaya Prasad Burle, T. Kiran, N. Anand, Diana Andrushia, K. Al-Jabri","doi":"10.1108/jsfe-01-2023-0016","DOIUrl":null,"url":null,"abstract":"PurposeThe construction industries at present are focusing on designing sustainable concrete with less carbon footprint. Considering this aspect, a Fibre-Reinforced Geopolymer Concrete (FGC) was developed with 8 and 10 molarities (M). At elevated temperatures, concrete experiences deterioration of its mechanical properties which is in some cases associated with spalling, leading to the building collapse.Design/methodology/approachIn this study, six geopolymer-based mix proportions are prepared with crimped steel fibre (SF), polypropylene fibre (PF), basalt fibre (BF), a hybrid mixture consisting of (SF + PF), a hybrid mixture with (SF + BF), and a reference specimen (without fibres). After temperature exposure, ultrasonic pulse velocity, physical characteristics of damaged concrete, loss of compressive strength (CS), split tensile strength (TS), and flexural strength (FS) of concrete are assessed. A polynomial relationship is developed between residual strength properties of concrete, and it showed a good agreement.FindingsThe test results concluded that concrete with BF showed a lower loss in CS after 925 °C (i.e. 60 min of heating) temperature exposure. In the case of TS, and FS, the concrete with SF had lesser loss in strength. After 986 °C and 1029 °C exposure, concrete with the hybrid combination (SF + BF) showed lower strength deterioration in CS, TS, and FS as compared to concrete with PF and SF + PF. The rate of reduction in strength is similar to that of GC-BF in CS, GC-SF in TS and FS.Originality/valuePerformance evaluation under fire exposure is necessary for FGC. In this study, we provided the mechanical behaviour and physical properties of SF, PF, and BF-based geopolymer concrete exposed to high temperatures, which were evaluated according to ISO standards. In addition, micro-structural behaviour and linear polynomials are observed.","PeriodicalId":45033,"journal":{"name":"Journal of Structural Fire Engineering","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Structural Fire Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/jsfe-01-2023-0016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

PurposeThe construction industries at present are focusing on designing sustainable concrete with less carbon footprint. Considering this aspect, a Fibre-Reinforced Geopolymer Concrete (FGC) was developed with 8 and 10 molarities (M). At elevated temperatures, concrete experiences deterioration of its mechanical properties which is in some cases associated with spalling, leading to the building collapse.Design/methodology/approachIn this study, six geopolymer-based mix proportions are prepared with crimped steel fibre (SF), polypropylene fibre (PF), basalt fibre (BF), a hybrid mixture consisting of (SF + PF), a hybrid mixture with (SF + BF), and a reference specimen (without fibres). After temperature exposure, ultrasonic pulse velocity, physical characteristics of damaged concrete, loss of compressive strength (CS), split tensile strength (TS), and flexural strength (FS) of concrete are assessed. A polynomial relationship is developed between residual strength properties of concrete, and it showed a good agreement.FindingsThe test results concluded that concrete with BF showed a lower loss in CS after 925 °C (i.e. 60 min of heating) temperature exposure. In the case of TS, and FS, the concrete with SF had lesser loss in strength. After 986 °C and 1029 °C exposure, concrete with the hybrid combination (SF + BF) showed lower strength deterioration in CS, TS, and FS as compared to concrete with PF and SF + PF. The rate of reduction in strength is similar to that of GC-BF in CS, GC-SF in TS and FS.Originality/valuePerformance evaluation under fire exposure is necessary for FGC. In this study, we provided the mechanical behaviour and physical properties of SF, PF, and BF-based geopolymer concrete exposed to high temperatures, which were evaluated according to ISO standards. In addition, micro-structural behaviour and linear polynomials are observed.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
纤维增强地质聚合物混凝土火灾后力学性能和物理特性研究
目的目前建筑业正致力于设计碳足迹更小的可持续混凝土。考虑到这一点,开发了一种具有8和10 molarities(M)的纤维增强地质聚合物混凝土(FGC)。在高温下,混凝土的力学性能会恶化,在某些情况下,这与剥落有关,导致建筑物倒塌。设计/方法/方法在本研究中,用卷曲钢纤维(SF)、聚丙烯纤维(PF)、玄武岩纤维(BF)、由(SF+PF)组成的混合混合物、具有(SF+BF)的混合混合物和参考样品(不含纤维)制备了六种基于地质聚合物的混合比例。在温度暴露后,评估了超声波脉冲速度、受损混凝土的物理特性、混凝土的抗压强度损失(CS)、劈拉强度(TS)和抗弯强度(FS)。建立了混凝土剩余强度特性之间的多项式关系,并显示出良好的一致性。结果试验结果表明,在925°C(即加热60分钟)的温度暴露后,BF混凝土的CS损失较低。在TS和FS的情况下,具有SF的混凝土强度损失较小。在986°C和1029°C暴露后,与PF和SF+PF的混凝土相比,混合组合(SF+BF)的混凝土在CS、TS和FS方面表现出较低的强度劣化。强度降低率与CS中的GC-BF、TS和FS中的GC-SF相似。原始性/价值FGC在火灾暴露下的性能评估是必要的。在这项研究中,我们提供了SF、PF和BF基地质聚合物混凝土在高温下的力学行为和物理性能,并根据ISO标准进行了评估。此外,还观察到了微观结构行为和线性多项式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Structural Fire Engineering
Journal of Structural Fire Engineering CONSTRUCTION & BUILDING TECHNOLOGY-
CiteScore
2.20
自引率
10.00%
发文量
28
期刊最新文献
Post-fire shear strengths of drilling screws and post-fire transitions of failure modes for screwed connections Combined effects of corrosion and fire on load-carrying response of hot-rolled steel reinforcement Influence of section profiles on flexural behavior of unsymmetrical cold formed steel sections – analytical and numerical investigation Estimating the elastic modulus of concrete under moderately elevated temperatures via impulse excitation technique Impact of the variability of material constitutive models on the thermal response of reinforced concrete walls
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1