Interaction phenomena of electrically coupled cells under local reactant starvation in automotive PEMFC stacks

IF 7 3区 材料科学 Q1 ENERGY & FUELS Journal of Physics-Energy Pub Date : 2023-09-08 DOI:10.1088/2515-7655/acf7f2
Jens Nissen, Max Schrievers, Johannes Frieder Huber, Jan N. Schwämmlein, Florian Henkel, Walter Theodor Czarnetzki, Markus Hölzle
{"title":"Interaction phenomena of electrically coupled cells under local reactant starvation in automotive PEMFC stacks","authors":"Jens Nissen, Max Schrievers, Johannes Frieder Huber, Jan N. Schwämmlein, Florian Henkel, Walter Theodor Czarnetzki, Markus Hölzle","doi":"10.1088/2515-7655/acf7f2","DOIUrl":null,"url":null,"abstract":"The local current density distribution of polymer electrolyte membrane fuel cells (PEMFCs) can be distorted by various error states. Differences in current density distributions (CDDs) of adjacent cells in a stack are equilibrized by in-plane currents within the sandwiched bipolar plates. Degradation stressors such as detrimental differences in local cell voltage and current density maxima can thus be generated. A novel method was therefore developed to intentionally manipulate CDD profiles by integrating local artificial starvation into only one fuel cell in an assembly. This technique is applied to automotive-sized PEMFCs single cells as well as in 20 cell short-stack to analyze such voltage and current redistribution phenomena. A drastic distortion of local cell voltage is only observed for stacks, which is explained by a supplementary simulation. The local voltage distribution of an electrically coupled fuel cell is therefore calculated by combining CDD measurements with a spatially resolved polarization curve model. The capabilities and limits of a multipoint cell voltage monitoring measurement device are discussed on this basis. The inspected correlation between these two independent online measurement techniques allows to localize such error states with considerable accuracy during operation of automotive sized PEMFC stacks.","PeriodicalId":48500,"journal":{"name":"Journal of Physics-Energy","volume":" ","pages":""},"PeriodicalIF":7.0000,"publicationDate":"2023-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics-Energy","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1088/2515-7655/acf7f2","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

The local current density distribution of polymer electrolyte membrane fuel cells (PEMFCs) can be distorted by various error states. Differences in current density distributions (CDDs) of adjacent cells in a stack are equilibrized by in-plane currents within the sandwiched bipolar plates. Degradation stressors such as detrimental differences in local cell voltage and current density maxima can thus be generated. A novel method was therefore developed to intentionally manipulate CDD profiles by integrating local artificial starvation into only one fuel cell in an assembly. This technique is applied to automotive-sized PEMFCs single cells as well as in 20 cell short-stack to analyze such voltage and current redistribution phenomena. A drastic distortion of local cell voltage is only observed for stacks, which is explained by a supplementary simulation. The local voltage distribution of an electrically coupled fuel cell is therefore calculated by combining CDD measurements with a spatially resolved polarization curve model. The capabilities and limits of a multipoint cell voltage monitoring measurement device are discussed on this basis. The inspected correlation between these two independent online measurement techniques allows to localize such error states with considerable accuracy during operation of automotive sized PEMFC stacks.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
汽车PEMFC堆中局部反应物缺乏下电耦合电池的相互作用现象
聚合物电解质膜燃料电池(PEMFCs)的局部电流密度分布会受到各种误差状态的扭曲。电流密度分布(cdd)的差异,相邻电池的堆叠是平衡的平面内电流在夹心双极板。因此,会产生诸如局部电池电压和电流密度最大值的有害差异等退化应力源。因此,开发了一种新的方法,通过将局部人工饥饿集成到组件中的一个燃料电池中来有意地操纵CDD剖面。该技术已应用于汽车尺寸的PEMFCs单电池和20电池短堆中,以分析这种电压和电流的再分布现象。仅在堆叠中观察到局部电池电压的剧烈畸变,这是通过补充模拟来解释的。因此,将CDD测量与空间分辨极化曲线模型相结合,计算了电耦合燃料电池的局部电压分布。在此基础上讨论了多点电池电压监测测量装置的性能和局限性。通过检测这两种独立在线测量技术之间的相关性,可以在汽车尺寸的PEMFC堆叠运行过程中以相当高的精度定位这些误差状态。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
10.90
自引率
1.40%
发文量
58
期刊介绍: The Journal of Physics-Energy is an interdisciplinary and fully open-access publication dedicated to setting the agenda for the identification and dissemination of the most exciting and significant advancements in all realms of energy-related research. Committed to the principles of open science, JPhys Energy is designed to maximize the exchange of knowledge between both established and emerging communities, thereby fostering a collaborative and inclusive environment for the advancement of energy research.
期刊最新文献
Hybrid energy storage systems for fast-developing renewable energy plants Critical review on the controllable growth and post-annealing on the heterojunction of the kesterite solar cells Synthesis and growth of solution-processed chiral perovskites Introduction of novel method of cyclic self-heating for the experimental quantification of the efficiency of caloric materials shown for LaFe11,4Mn0,35Si1,26Hx Effect of preparation routes on the performance of a multi-component AB2-type hydrogen storage alloy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1