Comanipulation Robotic Platform for Spine Surgery with Exteroceptive Visual Coupling: Development and Experimentation

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical Devices-Transactions of the Asme Pub Date : 2022-05-12 DOI:10.1115/1.4054550
Alizée Koszulinski, J. Sandoval, T. Vendeuvre, S. Zeghloul, M. Laribi
{"title":"Comanipulation Robotic Platform for Spine Surgery with Exteroceptive Visual Coupling: Development and Experimentation","authors":"Alizée Koszulinski, J. Sandoval, T. Vendeuvre, S. Zeghloul, M. Laribi","doi":"10.1115/1.4054550","DOIUrl":null,"url":null,"abstract":"\n In this paper, a novel surgical robotic platform intended to assist surgeons in cervical spine surgery is presented. The purpose of this surgery is to treat cervical spine instabilities. The surgical procedure requires drilling into specific region of the vertebrae in order to attach spinal implants and ensure a normal spacing between each vertebra. In this context, the proposed robotic platform allows to control and restrict surgeon's movements to a specific drilling direction set by the surgeon. The current platform is composed of a collaborative robot with 7 DoF equipped with a drilling tool and directly comanipulated by the surgeon. A motion capture system, as an exteroceptive sensor device, provides the robot controller with the movement data of the vertebra to be drilled. Robot Operating System (ROS) framework is used to enable real-time communication between the collaborative robot and the visual exteroceptive device. In addition, an implemented compliance control program allows to enhance the safety aspect of the robotic platform. Indeed, the collaborative robot follow the patient's movements while constraining the tool movements to an optimal trajectory as well as a limited drilling depth selected by the surgeon. The robot's elbow movements are also restricted by exploiting the null-space in order to avoid collisions with other equipment or medical team members. Experimental drilling trials have been performed by an orthopedic surgeon to validate the usefulness and different functionalities of the developed robotic platform, and provide that a collaborative robot can comply with spine surgery procedure.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4054550","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In this paper, a novel surgical robotic platform intended to assist surgeons in cervical spine surgery is presented. The purpose of this surgery is to treat cervical spine instabilities. The surgical procedure requires drilling into specific region of the vertebrae in order to attach spinal implants and ensure a normal spacing between each vertebra. In this context, the proposed robotic platform allows to control and restrict surgeon's movements to a specific drilling direction set by the surgeon. The current platform is composed of a collaborative robot with 7 DoF equipped with a drilling tool and directly comanipulated by the surgeon. A motion capture system, as an exteroceptive sensor device, provides the robot controller with the movement data of the vertebra to be drilled. Robot Operating System (ROS) framework is used to enable real-time communication between the collaborative robot and the visual exteroceptive device. In addition, an implemented compliance control program allows to enhance the safety aspect of the robotic platform. Indeed, the collaborative robot follow the patient's movements while constraining the tool movements to an optimal trajectory as well as a limited drilling depth selected by the surgeon. The robot's elbow movements are also restricted by exploiting the null-space in order to avoid collisions with other equipment or medical team members. Experimental drilling trials have been performed by an orthopedic surgeon to validate the usefulness and different functionalities of the developed robotic platform, and provide that a collaborative robot can comply with spine surgery procedure.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
具有视觉耦合的脊柱手术机器人操作平台的开发与实验
本文提出了一种新型的手术机器人平台,旨在帮助外科医生进行颈椎手术。这个手术的目的是治疗颈椎不稳。手术过程需要钻入脊椎的特定区域,以便连接脊椎植入物并确保每个脊椎之间的正常间距。在这种情况下,所提出的机器人平台允许控制和限制外科医生的运动到由外科医生设置的特定钻孔方向。目前的平台由一个带有7个DoF的协作机器人组成,该机器人配备了一个钻孔工具,并由外科医生直接操作。运动捕捉系统作为一种外部传感器设备,为机器人控制器提供要钻孔的椎骨的运动数据。机器人操作系统(ROS)框架用于实现协作机器人和视觉外部设备之间的实时通信。此外,实施的顺应性控制程序允许增强机器人平台的安全方面。事实上,协作机器人跟随患者的运动,同时将工具运动限制在最佳轨迹以及外科医生选择的有限钻孔深度。为了避免与其他设备或医疗团队成员发生碰撞,机器人的肘部运动也受到了利用零空间的限制。整形外科医生已经进行了实验钻孔试验,以验证所开发的机器人平台的有用性和不同功能,并提供协作机器人可以遵守脊柱手术程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
期刊最新文献
A Novel Design Method for the Knee Joint of the Exoskeleton Based On the Modular Wearable Sensor Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures Development And Mechanical Testing Of Implant For Cranial Reconstruction After Burr Hole Trepanation In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1