Clinical application of contrast-enhanced ultrasound combined with modified labeled method in locating sentinel lymph nodes of breast cancer

Yan Zheng, Jie Sun, Mengshang Hu, Lizhu Hou, Jianxia Liu, Feng-lin Dong
{"title":"Clinical application of contrast-enhanced ultrasound combined with modified labeled method in locating sentinel lymph nodes of breast cancer","authors":"Yan Zheng, Jie Sun, Mengshang Hu, Lizhu Hou, Jianxia Liu, Feng-lin Dong","doi":"10.3760/CMA.J.ISSN.1004-4477.2019.12.010","DOIUrl":null,"url":null,"abstract":"Objective \nTo explore the clinical value of contrast-enhanced ultrasound combined with modified labeled method in labeling sentinel lymph nodes of breast cancer in comparison with nano-carbon stained method. \n \n \nMethods \nEighty female breast cancer patients who underwent surgery in the First Affiliated Hospital of Soochow University between July 2017 and April 2019 were enrolled. Sentinel lymph nodes in all patients were labeled by contrast-enhanced ultrasound combined with modified labeled method and nano-carbon stained method, respectively. The consistency of first lymph node labeled by the two methods was judged, the number of SLNs labeled by two methods was counted, and the pathology of the labeled SLN was compared with that after axillary dissection. \n \n \nResults \nThe two methods have good consistency in locating sentinel lymph nodes of breast cancer(Kappa=0.749, P=0.000). The number of SLNs labeled by modified labeling method was significantly less than that labeled by stained method(Z=-7.434, P=0.000). The pathology of lymph nodes labeled by both the modified labeling method and stained method coincided well with that of axillary dissection(Kappa=0.941, 0.943; P=0.000, 0.000), and diagnostic efficiency was comparable(AUC=0.964, 0.967). \n \n \nConclusions \nContrast-enhanced ultrasound combined with modified labeling method is simple and accurate in labeling sentinel lymph nodes of breast cancer. Accurate assessment of axillary lymph node staging can be made by precise biopsy of 1-2 SLNs. \n \n \nKey words: \nContrast-enhanced ultrasound; Breast neoplasms; Sentinel lymph node; Biopsy","PeriodicalId":10224,"journal":{"name":"中华超声影像学杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华超声影像学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1004-4477.2019.12.010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To explore the clinical value of contrast-enhanced ultrasound combined with modified labeled method in labeling sentinel lymph nodes of breast cancer in comparison with nano-carbon stained method. Methods Eighty female breast cancer patients who underwent surgery in the First Affiliated Hospital of Soochow University between July 2017 and April 2019 were enrolled. Sentinel lymph nodes in all patients were labeled by contrast-enhanced ultrasound combined with modified labeled method and nano-carbon stained method, respectively. The consistency of first lymph node labeled by the two methods was judged, the number of SLNs labeled by two methods was counted, and the pathology of the labeled SLN was compared with that after axillary dissection. Results The two methods have good consistency in locating sentinel lymph nodes of breast cancer(Kappa=0.749, P=0.000). The number of SLNs labeled by modified labeling method was significantly less than that labeled by stained method(Z=-7.434, P=0.000). The pathology of lymph nodes labeled by both the modified labeling method and stained method coincided well with that of axillary dissection(Kappa=0.941, 0.943; P=0.000, 0.000), and diagnostic efficiency was comparable(AUC=0.964, 0.967). Conclusions Contrast-enhanced ultrasound combined with modified labeling method is simple and accurate in labeling sentinel lymph nodes of breast cancer. Accurate assessment of axillary lymph node staging can be made by precise biopsy of 1-2 SLNs. Key words: Contrast-enhanced ultrasound; Breast neoplasms; Sentinel lymph node; Biopsy
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声造影结合改良标记法在乳腺癌前哨淋巴结定位中的临床应用
目的探讨超声造影结合改良标记法与纳米碳染色法在癌症前哨淋巴结标记中的临床应用价值。方法对2017年7月至2019年4月在苏州大学第一附属医院接受手术治疗的80例女性癌症患者进行研究。分别采用超声造影结合改良标记法和纳米碳染色法对所有患者的前哨淋巴结进行标记。判断两种方法标记的第一个淋巴结的一致性,统计两种方法的SLN标记数量,并将标记的SLN与腋窝清扫后的病理进行比较。结果两种方法定位癌症前哨淋巴结具有良好的一致性(Kappa=0.4749,P=0.000),改良标记法标记的SLN数目明显少于染色法标记的(Z=7.434,P=0.000(Kappa=0.941,0.943;P=0.0002.000),诊断效率相当(AUC=0.964,0.967)。通过对1-2个前哨淋巴结进行精确的活检,可以准确评估腋窝淋巴结的分期。关键词:超声造影;乳腺肿瘤;哨兵淋巴结;活检
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中华超声影像学杂志
中华超声影像学杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.80
自引率
0.00%
发文量
9126
期刊介绍:
期刊最新文献
Ultrasound-guided pathological sampling of cadaver lung tissue in cases of COVID-19 Ultrasound-guided post-mortem tissue sampling in the autopsy of COVID-19 cases: a pilot study The clinical value of ultrasound in the assessment of the severity of COVID-19 Study of positioning of fetal conus medullaris by detecting atlanto-axial intervertebral space with three-dimensional ultrasound Prenatal ultrasound diagnostic clues of congenital dislocation of the knee
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1