Assessment of the feasibility of pool testing for SARS-CoV-2 infection screening

IF 4 4区 医学 Q1 INFECTIOUS DISEASES Infectious Diseases Pub Date : 2022-03-03 DOI:10.1080/23744235.2022.2044512
Irene Paganini, C. Sani, Chiara Chilleri, M. Baccini, Alberto Antonelli, S. Bisanzi, E. Burroni, F. Cellai, M. Coppi, F. Mealli, G. Pompeo, Jessica Viti, G. Rossolini, F. Carozzi
{"title":"Assessment of the feasibility of pool testing for SARS-CoV-2 infection screening","authors":"Irene Paganini, C. Sani, Chiara Chilleri, M. Baccini, Alberto Antonelli, S. Bisanzi, E. Burroni, F. Cellai, M. Coppi, F. Mealli, G. Pompeo, Jessica Viti, G. Rossolini, F. Carozzi","doi":"10.1080/23744235.2022.2044512","DOIUrl":null,"url":null,"abstract":"Abstract Background SARS-CoV-2 pandemic represented a huge challenge for national health systems worldwide. Pooling nasopharyngeal (NP) swabs seems to be a promising strategy, saving time and resources, but it could reduce the sensitivity of the RT-PCR and exacerbate samples management in terms of automation and tracing. In this study, taking advantage of the routine implementation of a screening plan on health workers, we evaluated the feasibility of pool testing for SARS-CoV-2 infection diagnosis in the presence of low viral load samples. Method Pools were prepared with an automated instrument, mixing 4, 6 or 20 NP specimens, including one, two or none positive samples. Ct values of positive samples were on average about 35 for the four genes analyzed. Results The overall sensitivity of 4-samples and 6-samples pools was 93.1 and 90.0%, respectively. Focussing on pools including one sample with Ct value ≥35 for all analyzed genes, sensitivity decreased to 77.8 and 75.0% for 4- and 6-samples, respectively; pools including two positive samples, resulted positive in any size as well as pools including positive samples with Ct values <35. Conclusion Pool testing strategy should account the balance between cost-effectiveness, dilution effect and prevalence of the infection. Our study demonstrated the good performances in terms of sensitivity and saving resources of pool testing mixing 4 or 6 samples, even including low viral load specimens, in a real screening context possibly affected by prevalence fluctuation. In conclusion, pool testing strategy represents an efficient and resources saving surveillance and tracing tool, especially in specific context like schools, even for monitoring changes in prevalence associated to vaccination campaign.","PeriodicalId":13671,"journal":{"name":"Infectious Diseases","volume":"54 1","pages":"478 - 487"},"PeriodicalIF":4.0000,"publicationDate":"2022-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/23744235.2022.2044512","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract Background SARS-CoV-2 pandemic represented a huge challenge for national health systems worldwide. Pooling nasopharyngeal (NP) swabs seems to be a promising strategy, saving time and resources, but it could reduce the sensitivity of the RT-PCR and exacerbate samples management in terms of automation and tracing. In this study, taking advantage of the routine implementation of a screening plan on health workers, we evaluated the feasibility of pool testing for SARS-CoV-2 infection diagnosis in the presence of low viral load samples. Method Pools were prepared with an automated instrument, mixing 4, 6 or 20 NP specimens, including one, two or none positive samples. Ct values of positive samples were on average about 35 for the four genes analyzed. Results The overall sensitivity of 4-samples and 6-samples pools was 93.1 and 90.0%, respectively. Focussing on pools including one sample with Ct value ≥35 for all analyzed genes, sensitivity decreased to 77.8 and 75.0% for 4- and 6-samples, respectively; pools including two positive samples, resulted positive in any size as well as pools including positive samples with Ct values <35. Conclusion Pool testing strategy should account the balance between cost-effectiveness, dilution effect and prevalence of the infection. Our study demonstrated the good performances in terms of sensitivity and saving resources of pool testing mixing 4 or 6 samples, even including low viral load specimens, in a real screening context possibly affected by prevalence fluctuation. In conclusion, pool testing strategy represents an efficient and resources saving surveillance and tracing tool, especially in specific context like schools, even for monitoring changes in prevalence associated to vaccination campaign.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SARS-CoV-2感染筛查池检测可行性评价
背景SARS-CoV-2大流行是全球各国卫生系统面临的巨大挑战。汇集鼻咽拭子似乎是一种很有前途的策略,可以节省时间和资源,但它可能降低RT-PCR的敏感性,并在自动化和追踪方面加剧样本管理。在本研究中,利用卫生工作者筛查计划的常规实施,我们评估了在存在低病毒载量样本的情况下进行SARS-CoV-2感染诊断的池检测的可行性。方法用自动仪器配制池,混合4、6或20份NP标本,包括1份、2份或无阳性标本。阳性样本的Ct值平均约为35。结果4个样本池和6个样本池的总灵敏度分别为93.1%和90.0%。当所有分析基因的Ct值≥35的样本均为一个样本时,4个样本和6个样本的敏感性分别降至77.8和75.0%;包含两个阳性样本的池,结果为任何大小的阳性样本,以及包含Ct值<35的阳性样本的池。结论池检测策略应兼顾成本-效果、稀释效应和感染流行之间的平衡。我们的研究表明,在可能受流行率波动影响的真实筛选环境中,混合4或6个样本(甚至包括低病毒载量样本)的池检测在灵敏度和节省资源方面具有良好的性能。总之,集中检测战略是一种有效和节省资源的监测和追踪工具,特别是在学校等特定环境中,甚至用于监测与疫苗接种运动相关的流行率变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Infectious Diseases
Infectious Diseases INFECTIOUS DISEASES-
CiteScore
8.20
自引率
1.70%
发文量
92
审稿时长
8 weeks
期刊介绍: Infectious Diseases (formerly Scandinavian Journal of Infectious Diseases) is a peer-reviewed journal publishing articles on all aspects of human infection, including pathogenesis, diagnosis, and treatment of infectious diseases, and also on medical microbiology and epidemiology
期刊最新文献
The silent invaders: Oropouche and Melao viruses, causes of increased public health risks for the Americas. Evaluation of the 2023 Duke-ISCVID criteria for infective endocarditis in patients referred to the Lund infective endocarditis team. Clinical evaluation of a highly multiplexed CRISPR-based diagnostic assay for diagnosing lower respiratory tract infection: a prospective cohort study. First cases of mpox Clade I outside of Africa: genetic insights on its evolution. Trends in decision-making by primary care physicians regarding common infectious complaints
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1