Comparison of Cutting Efficiency and Safety of 10/0.04 RaCe and Mtwo Rotary File Systems in Reaching the Full Root Canal Working Length: An In Vitro Study

IF 1.6 Q4 DENTISTRY, ORAL SURGERY & MEDICINE Dental Hypotheses Pub Date : 2022-01-01 DOI:10.4103/denthyp.denthyp_185_21
Pouya Abedi, Peiman Gilani, M. Fathollahi, F. Iranmanesh
{"title":"Comparison of Cutting Efficiency and Safety of 10/0.04 RaCe and Mtwo Rotary File Systems in Reaching the Full Root Canal Working Length: An In Vitro Study","authors":"Pouya Abedi, Peiman Gilani, M. Fathollahi, F. Iranmanesh","doi":"10.4103/denthyp.denthyp_185_21","DOIUrl":null,"url":null,"abstract":"Introduction: Both RaCe and Mtwo rotary systems introduced the 10/0.04 file as the first file used in the root canal (Glide path). This study aims to compare different factors of both the rotary systems, including cutting efficacy, file fracture, topography changes of files, and changes of the root canal. Materials and Methods: In this laboratory study, 12 RaCe and 12 Mtwo files were prepared and tested on 24 resin blocks with 30° curvature. The time to reach the working length was recorded. Topographical changes of the files have been observed with a stereomicroscope if needed. Changes in resin blocks were measured by photographing and using Photoshop software. Data were analyzed through an independent two-sample t test and likelihood-ratio chi-squared test. Results: Time to reach the working length was significantly lower in the RaCe group than in the Mtwo group (3.57 ± 0.56 s vs. 10.33 ± 2.25 s, P < 0.001). File fracture did not occur in any of the two rotary systems. Topographical changes of the files in RaCe group were also less than the Mtwo group (P = 0.032). Conclusion: The RaCe file is faster in reaching the working length. Both files are safe and do not cause drastic changes in the root canal.","PeriodicalId":43354,"journal":{"name":"Dental Hypotheses","volume":"13 1","pages":"6 - 9"},"PeriodicalIF":1.6000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Hypotheses","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/denthyp.denthyp_185_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Both RaCe and Mtwo rotary systems introduced the 10/0.04 file as the first file used in the root canal (Glide path). This study aims to compare different factors of both the rotary systems, including cutting efficacy, file fracture, topography changes of files, and changes of the root canal. Materials and Methods: In this laboratory study, 12 RaCe and 12 Mtwo files were prepared and tested on 24 resin blocks with 30° curvature. The time to reach the working length was recorded. Topographical changes of the files have been observed with a stereomicroscope if needed. Changes in resin blocks were measured by photographing and using Photoshop software. Data were analyzed through an independent two-sample t test and likelihood-ratio chi-squared test. Results: Time to reach the working length was significantly lower in the RaCe group than in the Mtwo group (3.57 ± 0.56 s vs. 10.33 ± 2.25 s, P < 0.001). File fracture did not occur in any of the two rotary systems. Topographical changes of the files in RaCe group were also less than the Mtwo group (P = 0.032). Conclusion: The RaCe file is faster in reaching the working length. Both files are safe and do not cause drastic changes in the root canal.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
10/0.04 RaCe和Mtwo旋转锉系统达到全根管工作长度的切削效率和安全性的比较:体外研究
简介:RaCe和Mtwo旋转系统都引入了10/0.04锉刀,作为根管中使用的第一个锉刀(Glide路径)。本研究旨在比较两种旋转系统的不同因素,包括切削效果、锉刀断裂、锉刀地形变化和根管变化。材料和方法:在本实验室研究中,制备了12个RaCe和12个Mtwo锉刀,并在24个30°的树脂块上进行了测试 曲率。记录达到工作长度的时间。如果需要,可以用立体显微镜观察文件的地形变化。通过拍照和使用Photoshop软件测量树脂块的变化。数据通过独立的双样本t检验和似然比卡方检验进行分析。结果:RaCe组达到工作长度的时间显著低于Mtwo组(3.57 ± 0.56 s与10.33 ± 2.25 s、 P<0.001)。两种旋转系统均未发生锉刀骨折。RaCe组的地形变化也小于Mtwo组(P = 0.032)。结论:RaCe文件达到工作长度的速度较快。这两种锉刀都是安全的,不会导致根管发生剧烈变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Dental Hypotheses
Dental Hypotheses DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.00
自引率
0.00%
发文量
16
审稿时长
21 weeks
期刊最新文献
Analysis of Salivary Levels of IL-8 and IL-34 in Periodontitis Patients: An Analytical Cross-Sectional Study Endodontic Microsurgery for a Mandibular First Molar With a Large Lateral Canal in Mesial Root: A Case Report Assessment of the Impact of Adhesive and Wires Types on the Tensile Bond Strength of Fixed Lingual Retainers Used in Orthodontics: An In Vitro Study Three-Dimensional Culture of Human Dental Pulp Tissue: A Preliminary Experimental In Vitro Model for Regenerative Endodontic Procedures Revolutionizing Systematic Reviews and Meta-analyses: The Role of Artificial Intelligence in Evidence Synthesis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1