Anesthetists’ Heart Rate Variability as an Indicator of Performance During Induction of General Anesthesia and Simulated Critical Incidents

IF 0.9 4区 心理学 Q4 NEUROSCIENCES Journal of Psychophysiology Pub Date : 2019-10-01 DOI:10.1027/0269-8803/A000225
F. Schneider, Jan Martin, Matthias Skrzypczak, D. Hinzmann, D. Jordan, K. Wagner, C. Schulz
{"title":"Anesthetists’ Heart Rate Variability as an Indicator of Performance During Induction of General Anesthesia and Simulated Critical Incidents","authors":"F. Schneider, Jan Martin, Matthias Skrzypczak, D. Hinzmann, D. Jordan, K. Wagner, C. Schulz","doi":"10.1027/0269-8803/A000225","DOIUrl":null,"url":null,"abstract":"Abstract. In the environment of anesthesia, good performance describes the absence of threat for the patient as well as a quick reaction to challenging and possibly life-threatening circumstances. Elsewhere, performance and cognitive function have been linked to indicators of vagally-mediated heart rate variability (HRV). This exploratory study examines the correlation between anesthetists’ HRV and their performance during uneventful induction of general anesthesia and during a simulated critical incident. For this study electrocardiograms (ECG) were obtained from two different groups of anesthetists providing general anesthesia in uneventful real cases in the operation room (OR, n = 38) and during the management of a hypotension scenario in a high-fidelity human patient simulator environment (SIM, n = 23). Frequency, time domain, and nonlinear HRV metrics were calculated from 5-min ECG recordings. To separate high performing (HP) and low performing (LP) individuals, the time needed for induction (in the OR setting) and the length and depth of hypotension (in the SIM setting) were used as performance correlates. The Mann-Whitney- U-test was used to assess differences in HRV within the groups. In both settings (OR and SIM), linear and nonlinear HRV metrics did not differ significantly between the HP and LP group. Also, the anesthetists’ work experience and sex were not related to performance. While providing general anesthesia and during a simulated critical incident, high and low performing individuals do not differ with respect to HRV metrics, sex, and work experience. Further research including the HRV under resting conditions is necessary.","PeriodicalId":50075,"journal":{"name":"Journal of Psychophysiology","volume":" ","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Psychophysiology","FirstCategoryId":"102","ListUrlMain":"https://doi.org/10.1027/0269-8803/A000225","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract. In the environment of anesthesia, good performance describes the absence of threat for the patient as well as a quick reaction to challenging and possibly life-threatening circumstances. Elsewhere, performance and cognitive function have been linked to indicators of vagally-mediated heart rate variability (HRV). This exploratory study examines the correlation between anesthetists’ HRV and their performance during uneventful induction of general anesthesia and during a simulated critical incident. For this study electrocardiograms (ECG) were obtained from two different groups of anesthetists providing general anesthesia in uneventful real cases in the operation room (OR, n = 38) and during the management of a hypotension scenario in a high-fidelity human patient simulator environment (SIM, n = 23). Frequency, time domain, and nonlinear HRV metrics were calculated from 5-min ECG recordings. To separate high performing (HP) and low performing (LP) individuals, the time needed for induction (in the OR setting) and the length and depth of hypotension (in the SIM setting) were used as performance correlates. The Mann-Whitney- U-test was used to assess differences in HRV within the groups. In both settings (OR and SIM), linear and nonlinear HRV metrics did not differ significantly between the HP and LP group. Also, the anesthetists’ work experience and sex were not related to performance. While providing general anesthesia and during a simulated critical incident, high and low performing individuals do not differ with respect to HRV metrics, sex, and work experience. Further research including the HRV under resting conditions is necessary.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
麻醉师的心率变异性作为全麻诱导和模拟危重事件期间表现的指标
摘要在麻醉环境中,良好的表现描述了对患者没有威胁以及对具有挑战性和可能危及生命的情况的快速反应。在其他方面,表现和认知功能与迷走神经介导的心率变异性(HRV)指标有关。本探索性研究探讨了麻醉师的HRV与他们在全身麻醉诱导和模拟危急事件期间的表现之间的相关性。在本研究中,两组麻醉师分别在手术室(OR, n = 38)和高保真人体患者模拟环境(SIM, n = 23)中进行全麻治疗,分别获得两组麻醉师的心电图(ECG)。频率、时域和非线性HRV指标从5分钟的心电图记录中计算。为了区分高表现(HP)和低表现(LP)个体,诱导所需的时间(在OR设置中)和低血压的长度和深度(在SIM设置中)被用作性能相关性。曼-惠特尼u型检验用于评估组内HRV的差异。在两种情况下(OR和SIM),线性和非线性HRV指标在HP组和LP组之间没有显着差异。此外,麻醉师的工作经验和性别与表现无关。在提供全身麻醉和模拟危急事件期间,高绩效和低绩效个体在HRV指标、性别和工作经验方面没有差异。包括静息条件下HRV的进一步研究是必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Psychophysiology
Journal of Psychophysiology 医学-神经科学
CiteScore
2.60
自引率
7.70%
发文量
25
审稿时长
>12 weeks
期刊介绍: The Journal of Psychophysiology is an international periodical that presents original research in all fields employing psychophysiological measures on human subjects. Contributions are published from psychology, physiology, clinical psychology, psychiatry, neurosciences, and pharmacology. Communications on new psychophysiological methods are presented as well. Space is also allocated for letters to the editor and book reviews. Occasional special issues are devoted to important current issues in psychophysiology.
期刊最新文献
Reviewers 2023 Neurocognitive Impairment in Non-Central Nervous System Cancer Survivors The Predictive Effects of Resting-State and Task-Related Prefrontal and Vagal Activity on Cognitive Performances Aggression Running Through Your Veins? The Relationship Between Heart Rate, Heart Rate Variability, and Aggression in Detained Juveniles Listen to Your Heart – Studying Heartbeat Detection and Emotional Intelligence
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1