[Resorcinol - determination method in the workplace air].

IF 0.8 4区 医学 Q4 PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH Medycyna pracy Pub Date : 2022-04-04 DOI:10.13075/mp.5893.01150
A. Jeżewska, D. Kondej
{"title":"[Resorcinol - determination method in the workplace air].","authors":"A. Jeżewska, D. Kondej","doi":"10.13075/mp.5893.01150","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nResorcinol (1,3-dihydroxybenzene) is a white solid used in rubber, pharmaceuticals, cosmetics, paints and varnishes and other industries. Resorcinol is a harmful, irritant, methemoglobin-forming and hemolytic substance. It can cause kidney and liver damage. The aim of the study was to develop a method for the determination of resorcinol in the workplace air, which would enable the determination of its concentrations in the range 0.1-2 of the MAC (maximum allowable concentration) value.\n\n\nMATERIAL AND METHODS\nThe method relies on passing the test air containing resorcinol through a cellulose filter, extraction with aqueous methanol solution and chromatographic analysis of the obtained solution. The tests were performed using a liquid chromatograph (HPLC) 1200 series of Agilent Technologies with a diode array detector (DAD). The determinations were carried out using an Allure Basix column (250 × 4.6 mm, 5 μm granulation). The procedure was validated according to European Standard PN-EN 482.\n\n\nRESULTS\nThe developed method allows the determination of resorcinol in the workplace air in the concentration range of 4.5-90 mg/m3. The limit of detection is 0.087 μg/ml, the precision 5.16% and the relative expanded uncertainty 22.6%. The method described enables selective determination of resorcinol in workplace air in the presence of 1,2-dihydroxybenzene, 1,4-dihydroxybenzene, benzene and phenol.\n\n\nCONCLUSIONS\nThe method is characterized by good precision and accuracy; it meets the requirements of the European Standard PN-EN 482, and can be used by occupational hygiene laboratories to measure concentrations of resorcinol in workplace air to assess workers' exposure to this substance. Med Pr. 2022;73(2).","PeriodicalId":18749,"journal":{"name":"Medycyna pracy","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2022-04-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medycyna pracy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.13075/mp.5893.01150","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND Resorcinol (1,3-dihydroxybenzene) is a white solid used in rubber, pharmaceuticals, cosmetics, paints and varnishes and other industries. Resorcinol is a harmful, irritant, methemoglobin-forming and hemolytic substance. It can cause kidney and liver damage. The aim of the study was to develop a method for the determination of resorcinol in the workplace air, which would enable the determination of its concentrations in the range 0.1-2 of the MAC (maximum allowable concentration) value. MATERIAL AND METHODS The method relies on passing the test air containing resorcinol through a cellulose filter, extraction with aqueous methanol solution and chromatographic analysis of the obtained solution. The tests were performed using a liquid chromatograph (HPLC) 1200 series of Agilent Technologies with a diode array detector (DAD). The determinations were carried out using an Allure Basix column (250 × 4.6 mm, 5 μm granulation). The procedure was validated according to European Standard PN-EN 482. RESULTS The developed method allows the determination of resorcinol in the workplace air in the concentration range of 4.5-90 mg/m3. The limit of detection is 0.087 μg/ml, the precision 5.16% and the relative expanded uncertainty 22.6%. The method described enables selective determination of resorcinol in workplace air in the presence of 1,2-dihydroxybenzene, 1,4-dihydroxybenzene, benzene and phenol. CONCLUSIONS The method is characterized by good precision and accuracy; it meets the requirements of the European Standard PN-EN 482, and can be used by occupational hygiene laboratories to measure concentrations of resorcinol in workplace air to assess workers' exposure to this substance. Med Pr. 2022;73(2).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[间苯二酚-工作场所空气中间苯二酚的测定方法]。
间苯二酚(1,3-二羟基苯)是一种白色固体,用于橡胶、制药、化妆品、油漆和清漆等行业。间苯二酚是一种有害的、刺激性的、形成高铁血红蛋白和溶血物质。它会导致肾脏和肝脏损伤。本研究的目的是开发一种测定工作场所空气中间苯二酚的方法,使其浓度在MAC(最大允许浓度)值的0.1-2范围内。材料和方法该方法依赖于将含有间苯二酚的测试空气通过纤维素过滤器,用甲醇水溶液提取,并对所得溶液进行色谱分析。采用安捷伦科技公司的1200系列液相色谱仪(HPLC)和二极管阵列检测器(DAD)进行检测。采用Allure Basix色谱柱(250 × 4.6 mm, 5 μm)进行测定。按照欧洲标准PN-EN 482进行验证。结果本方法可测定工作场所空气中间苯二酚的浓度范围为4.5 ~ 90 mg/m3。检出限为0.087 μg/ml,精密度5.16%,相对扩展不确定度22.6%。所描述的方法可以选择性地测定工作场所空气中存在1,2-二羟基苯、1,4-二羟基苯、苯和苯酚的间苯二酚。结论该方法精密度、准确度好;它符合欧洲标准PN-EN 482的要求,可用于职业卫生实验室测量工作场所空气中间苯二酚的浓度,以评估工人对该物质的暴露。中国生物医学工程学报,2012;33(2)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medycyna pracy
Medycyna pracy PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH-
CiteScore
1.90
自引率
10.00%
发文量
35
审稿时长
6-12 weeks
期刊介绍: The journal publishes original papers, review papers and case studies in Polish and English. The subject matter of the articles includes occupational pathology, physical, chemical and biological agents at workplace, toxicology, mutagenesis, health policy, health management, health care, epidemiology, etc. The magazine also includes reports from national and international scientific conferences on occupational medicine. It also contains letters to the editor. Each first-in-year issue of the magazine comprises former-year indices of authors and keywords.
期刊最新文献
Erratum to Raposo et al. “Increasing awareness and empathy among university students through immersive exercises – testing of the virtual reality application: A pilot study” (Med Pr 2023;74(3):187–197) Accidents rate of the Polish State Fire Service officers during service in the years 2015–2022 Assessment of the suitability of selected non-measuring models for dermal exposure estimation for the purposes of assessing compliance of working conditions with restrictions 71 and 76 in Annex XVII of the REACH regulation The influence of silver nanoparticles on the process of epithelial-mesenchymal transition in the context of cancer metastases Satisfaction with nursing care of hospitalized patients: A descriptive, cross-sectional, multicenter study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1