Francisco Fernández-Zacarías, Juan Luis Beira-Jiménez, Virginia Puyana-Romero, Ricardo Hernández-Molina
{"title":"Diagnosis of Noise Inside Neonatal Incubators under Free-Field Conditions","authors":"Francisco Fernández-Zacarías, Juan Luis Beira-Jiménez, Virginia Puyana-Romero, Ricardo Hernández-Molina","doi":"10.3390/acoustics5020021","DOIUrl":null,"url":null,"abstract":"The study aims to diagnose the sound pressure levels inside incubators in a controlled environment under free-field conditions. The tests were carried out in a semi-anechoic room under the standard UNE-EN ISO 3745:2012/A1:2018 in three different operating states: off, on, and on with a temperature alarm triggered. Sound pressure levels were analyzed in three different models of incubators, both inside and outside. The main noise indices analyzed were the corrected equivalent continuous level (LKeq) and the equivalent continuous level (Leq) in third-octave bands. The results obtained under normal operating conditions showed variations among the different incubators, with overall values between 48.8 and 56.3 dBA. The influence of the alarm considerably worsened these data. The values obtained showed that premature newborns are exposed to noise levels above international recommendations. All incubators tested showed the presence of tonal components, both outside and inside the incubator cabin, and, in some cases, low-frequency components, but no impulsivity components were observed in any case.","PeriodicalId":72045,"journal":{"name":"Acoustics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2023-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acoustics (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/acoustics5020021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ACOUSTICS","Score":null,"Total":0}
引用次数: 0
Abstract
The study aims to diagnose the sound pressure levels inside incubators in a controlled environment under free-field conditions. The tests were carried out in a semi-anechoic room under the standard UNE-EN ISO 3745:2012/A1:2018 in three different operating states: off, on, and on with a temperature alarm triggered. Sound pressure levels were analyzed in three different models of incubators, both inside and outside. The main noise indices analyzed were the corrected equivalent continuous level (LKeq) and the equivalent continuous level (Leq) in third-octave bands. The results obtained under normal operating conditions showed variations among the different incubators, with overall values between 48.8 and 56.3 dBA. The influence of the alarm considerably worsened these data. The values obtained showed that premature newborns are exposed to noise levels above international recommendations. All incubators tested showed the presence of tonal components, both outside and inside the incubator cabin, and, in some cases, low-frequency components, but no impulsivity components were observed in any case.
该研究旨在诊断在自由场条件下受控环境下孵化器内的声压级。测试在半消声室内进行,符合UNE-EN ISO 3745:2012/A1:2018标准,在三种不同的工作状态下进行:关闭、打开和打开,并触发温度警报。分析了三种不同型号恒温箱内、外的声压级。分析的主要噪声指标是校正后的等效连续电平(LKeq)和三倍频程的等效连续电平(Leq)。在正常操作条件下获得的结果显示,不同的培养箱之间存在差异,总体值在48.8到56.3 dBA之间。警报的影响大大恶化了这些数据。所获得的数值表明,早产新生儿接触到的噪音水平高于国际建议水平。所有测试的孵化器都显示出音调成分的存在,在孵化器舱室内外,在某些情况下,低频成分,但在任何情况下都没有观察到冲动性成分。