Simulation of a single-stage evaporator system integrated with a mechanical vapor compressor for concentrating the electrolytic system KNO3 – H2O

Ervin Karić, Rejha Alić
{"title":"Simulation of a single-stage evaporator system integrated with a mechanical vapor compressor for concentrating the electrolytic system KNO3 – H2O","authors":"Ervin Karić, Rejha Alić","doi":"10.7251/jepm2002050k","DOIUrl":null,"url":null,"abstract":"A simulation of a single-stage evaporator system integrated with a mechanical com- pressor for a case study (concentrating the electrolytic system KNO3 – H2O) was performed. A mathematical model of the subsystem of a single-stage evaporator, a mechanical compressor, and superheated steam seeding is presented. Microsoft Excel with VBA (Visual Basic for Application) was used to solve the mathematical model. The model was solved by an iterative method where the values of the in- let stream temperature and the salt concentration in the concentrated stream at the evaporator outlet were assumed. The process parameters of the system have been determined. Since the goal of any industrial process is to minimize costs and maximize products, the impact of mean temperature difference changes on satu- ration water consumption and molar salt content in the concentrated stream was presented. 106.92 kg/h of freshwater are required to obtain 18% by weight of salt in a concentrated stream, while 432.30 kg/h of fresh water are required to obtain 25% by weight of salt in a concentrated stream. Consumption of heating steam ranged from 1760.31 to 4473.4 kg/h depending on the average temperature dif- ference. By increasing the temperature differences from 10 to 25 ◦C, the amount of transferred upper lines increases from 1025 to 2750 kW, which is an advantage of increasing the mean temperature difference. The disadvantage of the larger tem- perature difference is the increase in the power of the mechanical compressor from 97.02 to 384.12 kW.","PeriodicalId":53038,"journal":{"name":"Journal of Engineering Processing Management","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering Processing Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7251/jepm2002050k","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A simulation of a single-stage evaporator system integrated with a mechanical com- pressor for a case study (concentrating the electrolytic system KNO3 – H2O) was performed. A mathematical model of the subsystem of a single-stage evaporator, a mechanical compressor, and superheated steam seeding is presented. Microsoft Excel with VBA (Visual Basic for Application) was used to solve the mathematical model. The model was solved by an iterative method where the values of the in- let stream temperature and the salt concentration in the concentrated stream at the evaporator outlet were assumed. The process parameters of the system have been determined. Since the goal of any industrial process is to minimize costs and maximize products, the impact of mean temperature difference changes on satu- ration water consumption and molar salt content in the concentrated stream was presented. 106.92 kg/h of freshwater are required to obtain 18% by weight of salt in a concentrated stream, while 432.30 kg/h of fresh water are required to obtain 25% by weight of salt in a concentrated stream. Consumption of heating steam ranged from 1760.31 to 4473.4 kg/h depending on the average temperature dif- ference. By increasing the temperature differences from 10 to 25 ◦C, the amount of transferred upper lines increases from 1025 to 2750 kW, which is an advantage of increasing the mean temperature difference. The disadvantage of the larger tem- perature difference is the increase in the power of the mechanical compressor from 97.02 to 384.12 kW.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
与机械蒸汽压缩机集成的单级蒸发器系统的模拟,用于浓缩电解系统KNO3–H2O
对与机械压缩机集成的单级蒸发器系统进行了模拟,以进行案例研究(浓缩电解系统KNO3–H2O)。建立了单级蒸发器、机械压缩机和过热蒸汽播种子系统的数学模型。使用Microsoft Excel和VBA(Visual Basic for Application)对数学模型进行求解。该模型通过迭代方法求解,其中假设蒸发器出口处浓流中的入流温度和盐浓度的值。系统的工艺参数已经确定。由于任何工业过程的目标都是最小化成本和最大化产品,因此介绍了平均温差变化对饱和水消耗和浓物流中摩尔盐含量的影响。需要106.92千克/小时的淡水才能在浓缩流中获得18%重量的盐,而需要432.30千克/小时淡水才能在浓流中获得25%重量的盐。加热蒸汽消耗量在1760.31至4473.4 kg/h之间,具体取决于平均温差。通过将温差从10增加到25◦C、 传输的上层线路的量从1025kW增加到2750kW,这是增加平均温差的优点。温差较大的缺点是机械压缩机的功率从97.02增加到384.12 kW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
15 weeks
期刊最新文献
Neural network modeling methods for predicting the air parameters in the city of Tuzla Quality testing of industrially produced essential oil of white pine (Pinus sylvestris L.) from the Republic of Srpska 3D model of a Monolithic Honeycomb Adsorber for Electric Swing Adsorption for Carbon Dioxide Capture Cloud Point Extraction as a Method for Preconcentration of Metal Ions Effects of drilling parameters on TI-6Al-4V alloy using different coolants
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1