{"title":"Electrochemical Method Development for Enalapril Determination in a Pharmaceutical Formulation","authors":"A. Amro","doi":"10.22377/ajp.v14i4.3822","DOIUrl":null,"url":null,"abstract":"Aims: The present study focuses on a comparison between three voltammetric methods for enalapril assay in a pharmaceutical formulation, in addition to optimization of voltammetric analysis parameters such as working electrode and supporting electrolyte. Materials and Methods: Glassy carbon (GC) working electrode and KNO3 (1 M) supporting electrolyte exhibited the best performance compared to other working electrodes and supporting electrolytes used in this study. Results and Discussion: Voltammograms of enalapril exhibited two oxidization peaks at 1.4 V and 1.75 V. Square wave voltammetry (SWV) showed the lowest limit of detection (LOD) and limit of quantitation (LOQ) with values of 90.1 and 247 μg/mL LOD and LOQ, respectively. Furthermore, SWV exhibited the lowest relative standard deviation values of 2.33 and 3.87% for inter and intraday analysis, respectively. SWV showed high-performance in recovery study of commercially available enalapril tablets ANGIOTEC 20 mg® reach 99.06%. Conclusion: Accuracy, precession, and detection limit of SWV are the best for enalapril analysis compared to other methods in this study.","PeriodicalId":8489,"journal":{"name":"Asian Journal of Pharmaceutics","volume":" ","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2020-11-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Pharmaceutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22377/ajp.v14i4.3822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: The present study focuses on a comparison between three voltammetric methods for enalapril assay in a pharmaceutical formulation, in addition to optimization of voltammetric analysis parameters such as working electrode and supporting electrolyte. Materials and Methods: Glassy carbon (GC) working electrode and KNO3 (1 M) supporting electrolyte exhibited the best performance compared to other working electrodes and supporting electrolytes used in this study. Results and Discussion: Voltammograms of enalapril exhibited two oxidization peaks at 1.4 V and 1.75 V. Square wave voltammetry (SWV) showed the lowest limit of detection (LOD) and limit of quantitation (LOQ) with values of 90.1 and 247 μg/mL LOD and LOQ, respectively. Furthermore, SWV exhibited the lowest relative standard deviation values of 2.33 and 3.87% for inter and intraday analysis, respectively. SWV showed high-performance in recovery study of commercially available enalapril tablets ANGIOTEC 20 mg® reach 99.06%. Conclusion: Accuracy, precession, and detection limit of SWV are the best for enalapril analysis compared to other methods in this study.
期刊介绍:
Character of the publications: -Pharmaceutics and Pharmaceutical Technology -Formulation Design and Development -Drug Discovery and Development Interface -Manufacturing Science and Engineering -Pharmacokinetics, Pharmacodynamics, and Drug Metabolism -Clinical Pharmacology, General Medicine and Translational Research -Physical Pharmacy and Biopharmaceutics -Novel Drug delivery system -Biotechnology & Microbiological evaluations -Regulatory Sciences