Pre-Clinical Evaluation of a Task-Shifting Contraceptive Implant Insertion Device for Use in Low- and Middle-Income Countries

IF 0.8 4区 医学 Q4 ENGINEERING, BIOMEDICAL Journal of Medical Devices-Transactions of the Asme Pub Date : 2022-05-29 DOI:10.1115/1.4054684
I. Mohedas, Carrie Bell, Betregiorgis Hailu Zegeye, KevinC Jiang, Caroline Soyars, Madeleine Walsh, K. Sienko
{"title":"Pre-Clinical Evaluation of a Task-Shifting Contraceptive Implant Insertion Device for Use in Low- and Middle-Income Countries","authors":"I. Mohedas, Carrie Bell, Betregiorgis Hailu Zegeye, KevinC Jiang, Caroline Soyars, Madeleine Walsh, K. Sienko","doi":"10.1115/1.4054684","DOIUrl":null,"url":null,"abstract":"\n Worldwide, 225 million women have unmet contraceptive needs which, every year, leads to 52 million unintended pregnancies. A challenge to providing universal access to contraception is the large proportion of the population living in rural, difficult to access settings in low- and middle-income countries. The availability and delivery of effective contraception in rural areas is limited by the lack of trained healthcare providers. Barriers to the use of long-acting contraceptives in rural areas are more pronounced due to the advanced skill and training to administer. In this study, we describe the design and testing of the SubQ Assist, a task-shifting contraceptive implant insertion device that aims to reduce the training requirements for administering contraceptive implants while simultaneously ensuring safe and high quality administration. Cadaver testing in conjunction with ultrasound depth measurements were used to evaluate the efficacy of the SubQ Assist. Implant insertion between the SubQ Assist and a trained physician are compared. Cadaver testing and ultrasound depth measurements demonstrate that the SubQ Assist results in implant insertions that are statistically equivalent to implants inserted by a trained physician. Additionally, the results show that the lateral positioning of these implants would facilitate uncomplicated removal at a later date. These findings demonstrate proof of concept for the SubQ Assist and provide evidence for moving towards clinical testing. They demonstrate that the SubQ Assist may be an effective method of task-shifting the insertion of contraceptive implants to minimally trained providers in order to expand access in rural areas.","PeriodicalId":49305,"journal":{"name":"Journal of Medical Devices-Transactions of the Asme","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Devices-Transactions of the Asme","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1115/1.4054684","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Worldwide, 225 million women have unmet contraceptive needs which, every year, leads to 52 million unintended pregnancies. A challenge to providing universal access to contraception is the large proportion of the population living in rural, difficult to access settings in low- and middle-income countries. The availability and delivery of effective contraception in rural areas is limited by the lack of trained healthcare providers. Barriers to the use of long-acting contraceptives in rural areas are more pronounced due to the advanced skill and training to administer. In this study, we describe the design and testing of the SubQ Assist, a task-shifting contraceptive implant insertion device that aims to reduce the training requirements for administering contraceptive implants while simultaneously ensuring safe and high quality administration. Cadaver testing in conjunction with ultrasound depth measurements were used to evaluate the efficacy of the SubQ Assist. Implant insertion between the SubQ Assist and a trained physician are compared. Cadaver testing and ultrasound depth measurements demonstrate that the SubQ Assist results in implant insertions that are statistically equivalent to implants inserted by a trained physician. Additionally, the results show that the lateral positioning of these implants would facilitate uncomplicated removal at a later date. These findings demonstrate proof of concept for the SubQ Assist and provide evidence for moving towards clinical testing. They demonstrate that the SubQ Assist may be an effective method of task-shifting the insertion of contraceptive implants to minimally trained providers in order to expand access in rural areas.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在低收入和中等收入国家使用的任务转移避孕植入插入装置的临床前评估
全世界有2.25亿妇女的避孕需求未得到满足,每年导致5200万例意外怀孕。普及避孕措施面临的一个挑战是,低收入和中等收入国家有很大一部分人口生活在难以获得避孕措施的农村地区。由于缺乏训练有素的保健服务提供者,农村地区有效避孕措施的供应和提供受到限制。在农村地区使用长效避孕药具的障碍更为明显,这是由于使用避孕药具的高级技能和培训。在这项研究中,我们描述了SubQ Assist的设计和测试,这是一种任务转移避孕植入物插入装置,旨在减少管理避孕植入物的培训要求,同时确保安全和高质量的管理。尸体试验结合超声深度测量来评估SubQ Assist的疗效。比较SubQ Assist和训练有素的医生之间的植入物插入。尸体测试和超声深度测量表明,在统计上,SubQ Assist植入的植入物与训练有素的医生植入的植入物相当。此外,结果表明,这些植入物的侧向定位将有助于在以后的日期简单的移除。这些发现证明了SubQ Assist的概念,并为走向临床测试提供了证据。他们证明,SubQ Assist可能是一种有效的方法,将避孕植入物的插入任务转移到最低限度训练的提供者,以扩大农村地区的可及性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.80
自引率
11.10%
发文量
56
审稿时长
6-12 weeks
期刊介绍: The Journal of Medical Devices presents papers on medical devices that improve diagnostic, interventional and therapeutic treatments focusing on applied research and the development of new medical devices or instrumentation. It provides special coverage of novel devices that allow new surgical strategies, new methods of drug delivery, or possible reductions in the complexity, cost, or adverse results of health care. The Design Innovation category features papers focusing on novel devices, including papers with limited clinical or engineering results. The Medical Device News section provides coverage of advances, trends, and events.
期刊最新文献
A Novel Design Method for the Knee Joint of the Exoskeleton Based On the Modular Wearable Sensor Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy Assessment of a Novel Application of the Capture-Trap-Terminate Approach for Treating Aerosol Products During Dental Procedures Development And Mechanical Testing Of Implant For Cranial Reconstruction After Burr Hole Trepanation In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1