{"title":"Numerical study of a centrifugal electromagnetic induction pump with zero flowrate","authors":"","doi":"10.22364/mhd.58.1-2.18","DOIUrl":null,"url":null,"abstract":"The objective of the present study is to develop a numerical model of the centrifugal electromagnetic induction pump to predict the developed pressure in the case of zero flowrate. This is done using the COMSOL Multiphysics software in a 2D space with a time harmonic approach. A good agreement with previously reported experimental results was obtained. Based on the developed model, a study of the linear electromagnetic induction pump is also carried out and the obtained results are compared with those for the centrifugal electromagnetic induction pump. It is shown that with a low interaction parameter, the centrifugal pump can develop a significantly higher pressure than the linear pump. Figs 12, Refs 5.","PeriodicalId":18136,"journal":{"name":"Magnetohydrodynamics","volume":" ","pages":""},"PeriodicalIF":0.3000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetohydrodynamics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.22364/mhd.58.1-2.18","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MECHANICS","Score":null,"Total":0}
引用次数: 0
Abstract
The objective of the present study is to develop a numerical model of the centrifugal electromagnetic induction pump to predict the developed pressure in the case of zero flowrate. This is done using the COMSOL Multiphysics software in a 2D space with a time harmonic approach. A good agreement with previously reported experimental results was obtained. Based on the developed model, a study of the linear electromagnetic induction pump is also carried out and the obtained results are compared with those for the centrifugal electromagnetic induction pump. It is shown that with a low interaction parameter, the centrifugal pump can develop a significantly higher pressure than the linear pump. Figs 12, Refs 5.