Safety and efficacy profile of an indigenous developed CHARAK DDDR 747R dual-chamber rate-responsive pacemaker: A prospective study from a tertiary care center in North India

Q4 Medicine Heart India Pub Date : 2022-09-01 DOI:10.4103/heartindia.heartindia_38_22
Y. Sharma, Akash Batta, S. Mehrotra, P. Panda, S. Sethi
{"title":"Safety and efficacy profile of an indigenous developed CHARAK DDDR 747R dual-chamber rate-responsive pacemaker: A prospective study from a tertiary care center in North India","authors":"Y. Sharma, Akash Batta, S. Mehrotra, P. Panda, S. Sethi","doi":"10.4103/heartindia.heartindia_38_22","DOIUrl":null,"url":null,"abstract":"Aim: The purpose of this study was to assess the safety and performance of the domestically manufactured Charak DDDR 747R (Pacetronix Ltd, Indore, India) pacemaker device. Materials and Methods: This was a prospective, controlled, single-center study conducted between March 2016 and August 2017. Eligible patients were implanted with a Charak DDDR 747R pacemaker with parameters set as specified on the packaging material unless otherwise advised by the physician. Patients were evaluated before discharge and at the 18-month follow-up. Data such as patient age, gender, and medical history were collected to determine patient eligibility for study participation, monitoring of study progress, and data analysis. Results: A total of 35 patients were analyzed. Males comprised 45.7% and females comprised 54.3% of patients. The average pacing threshold was threshold (atrium) was 1.05 V and the average pacing threshold (ventricle) was 1.07 V. The average impedance (atrium) was 641.09 Ω and the average impedance (ventricle) was 719.31 Ω. No serious adverse events were documented during the follow-up. One death occurred; however, this was not device-related. Conclusions: As per study findings, the Charak DDDR 747R, an indigenous pacemaker, is safe and effective in the Indian population. Durable lead parameters were obtained during the study which remained stable over time referring the same. Future larger studies are needed to confirm the preliminary data obtained from our study.","PeriodicalId":32147,"journal":{"name":"Heart India","volume":"10 1","pages":"147 - 151"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart India","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/heartindia.heartindia_38_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The purpose of this study was to assess the safety and performance of the domestically manufactured Charak DDDR 747R (Pacetronix Ltd, Indore, India) pacemaker device. Materials and Methods: This was a prospective, controlled, single-center study conducted between March 2016 and August 2017. Eligible patients were implanted with a Charak DDDR 747R pacemaker with parameters set as specified on the packaging material unless otherwise advised by the physician. Patients were evaluated before discharge and at the 18-month follow-up. Data such as patient age, gender, and medical history were collected to determine patient eligibility for study participation, monitoring of study progress, and data analysis. Results: A total of 35 patients were analyzed. Males comprised 45.7% and females comprised 54.3% of patients. The average pacing threshold was threshold (atrium) was 1.05 V and the average pacing threshold (ventricle) was 1.07 V. The average impedance (atrium) was 641.09 Ω and the average impedance (ventricle) was 719.31 Ω. No serious adverse events were documented during the follow-up. One death occurred; however, this was not device-related. Conclusions: As per study findings, the Charak DDDR 747R, an indigenous pacemaker, is safe and effective in the Indian population. Durable lead parameters were obtained during the study which remained stable over time referring the same. Future larger studies are needed to confirm the preliminary data obtained from our study.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
国产CHARAK DDDR 747R双腔速率响应起搏器的安全性和有效性:来自北印度一家三级医疗中心的前瞻性研究
目的:本研究旨在评估国产Charak DDDR 747R(Pacetronix Ltd,Indore,India)起搏器的安全性和性能。材料和方法:这是一项前瞻性、对照性、单中心研究,于2016年3月至2017年8月进行。符合条件的患者植入Charak DDDR 747R起搏器,其参数按照包装材料上的规定设置,除非医生另有建议。患者在出院前和18个月随访时进行评估。收集患者年龄、性别和病史等数据,以确定患者是否有资格参与研究、监测研究进展和数据分析。结果:共对35例患者进行了分析。男性占45.7%,女性占54.3%。平均起搏阈值为阈值(心房)1.05V,平均起搏阈值(心室)1.07V。平均阻抗(心房)641.09Ω,平均阻抗(心室)719.31Ω。随访期间未记录严重不良事件。一人死亡;然而,这与设备无关。结论:根据研究结果,Charak DDDR 747R是一种本土起搏器,在印度人群中是安全有效的。在研究过程中获得了耐用的导线参数,这些参数随着时间的推移保持稳定。未来需要更大规模的研究来证实从我们的研究中获得的初步数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
0
审稿时长
27 weeks
期刊最新文献
Preface to the second issue of Heart India 2023 Correlation of diabetes complications with blood pressure variability Achromobacter: A bug in prosthetic heart valve Assessment of neurodevelopmental status using Development Assessment Scale for Indian Infants in children 6-24 months of age with congenital heart disease A single-center retrospective study of Vitamin D status and acute left ventricular heart failure from a super specialty tertiary care hospital in Northeast India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1