Broadband transparent ultrasound transducer with polymethyl methacrylate as matching layer for in vivo photoacoustic microscopy

IF 6.8 1区 医学 Q1 ENGINEERING, BIOMEDICAL Photoacoustics Pub Date : 2023-10-01 DOI:10.1016/j.pacs.2023.100548
Jiaming Zhang , Xing Long , Guangjie Zhang , Zhongtian Ma , Wenzhao Li , Yibing Wang , Fan Yang , Riqiang Lin , Changhui Li , Kwok-Ho Lam
{"title":"Broadband transparent ultrasound transducer with polymethyl methacrylate as matching layer for in vivo photoacoustic microscopy","authors":"Jiaming Zhang ,&nbsp;Xing Long ,&nbsp;Guangjie Zhang ,&nbsp;Zhongtian Ma ,&nbsp;Wenzhao Li ,&nbsp;Yibing Wang ,&nbsp;Fan Yang ,&nbsp;Riqiang Lin ,&nbsp;Changhui Li ,&nbsp;Kwok-Ho Lam","doi":"10.1016/j.pacs.2023.100548","DOIUrl":null,"url":null,"abstract":"<div><p>Photoacoustic imaging (PAI) uniquely combines optics and ultrasound, presenting a promising role in biomedical imaging as a non-invasive and label-free imaging technology. As the traditional opaque ultrasound (US) transducers could hinder the transportation of the excitation light and limit the performance of PAI system, piezoelectric transparent ultrasonic transducers (TUTs) with indium tin oxide (ITO) electrodes have been developed to allow light transmission through the transducer and illuminate the sample directly. Nevertheless, without having transparent matching materials with appropriate properties, the bandwidth of those TUTs was generally narrow. In this work, we propose to employ polymethyl methacrylate (PMMA) as the matching layer material to improve the bandwidth of lithium niobate (LN)-based TUTs. The effects of PMMA matching layer on the performance of TUTs have been systematically studied. With the optimized PMMA matching layer, the very wide bandwidth of &gt; 50 % could be achieved for the TUTs even with different transducer frequencies, leading to the great enhancement of axial resolution when compared to the similar reported work. In addition, the imaging performance of the developed TUT prototype has been evaluated in a PAI system and demonstrated by both phantom and <em>in vivo</em> small animal imaging.</p></div>","PeriodicalId":56025,"journal":{"name":"Photoacoustics","volume":"33 ","pages":"Article 100548"},"PeriodicalIF":6.8000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photoacoustics","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213597923001015","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Photoacoustic imaging (PAI) uniquely combines optics and ultrasound, presenting a promising role in biomedical imaging as a non-invasive and label-free imaging technology. As the traditional opaque ultrasound (US) transducers could hinder the transportation of the excitation light and limit the performance of PAI system, piezoelectric transparent ultrasonic transducers (TUTs) with indium tin oxide (ITO) electrodes have been developed to allow light transmission through the transducer and illuminate the sample directly. Nevertheless, without having transparent matching materials with appropriate properties, the bandwidth of those TUTs was generally narrow. In this work, we propose to employ polymethyl methacrylate (PMMA) as the matching layer material to improve the bandwidth of lithium niobate (LN)-based TUTs. The effects of PMMA matching layer on the performance of TUTs have been systematically studied. With the optimized PMMA matching layer, the very wide bandwidth of > 50 % could be achieved for the TUTs even with different transducer frequencies, leading to the great enhancement of axial resolution when compared to the similar reported work. In addition, the imaging performance of the developed TUT prototype has been evaluated in a PAI system and demonstrated by both phantom and in vivo small animal imaging.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于体内光声显微镜的聚甲基丙烯酸甲酯匹配层宽带透明超声换能器
光声成像(PAI)将光学和超声独特地结合在一起,作为一种无创、无标签的成像技术,在生物医学成像中发挥着很有前途的作用。由于传统的不透明超声换能器会阻碍激发光的传输并限制PAI系统的性能,因此已经开发出具有铟锡氧化物(ITO)电极的压电透明超声换能器(TUT),以允许光透射通过换能器并直接照射样品。然而,在没有具有适当性能的透明匹配材料的情况下,这些TUT的带宽通常很窄。在这项工作中,我们建议使用聚甲基丙烯酸甲酯(PMMA)作为匹配层材料来提高铌酸锂(LN)基TUT的带宽。系统地研究了PMMA匹配层对TUT性能的影响。通过优化的PMMA匹配层,>; 即使使用不同的换能器频率,TUT也可以达到50%,与类似报道的工作相比,轴向分辨率大大提高。此外,所开发的TUT原型的成像性能已在PAI系统中进行了评估,并通过体模和体内小动物成像进行了验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Photoacoustics
Photoacoustics Physics and Astronomy-Atomic and Molecular Physics, and Optics
CiteScore
11.40
自引率
16.50%
发文量
96
审稿时长
53 days
期刊介绍: The open access Photoacoustics journal (PACS) aims to publish original research and review contributions in the field of photoacoustics-optoacoustics-thermoacoustics. This field utilizes acoustical and ultrasonic phenomena excited by electromagnetic radiation for the detection, visualization, and characterization of various materials and biological tissues, including living organisms. Recent advancements in laser technologies, ultrasound detection approaches, inverse theory, and fast reconstruction algorithms have greatly supported the rapid progress in this field. The unique contrast provided by molecular absorption in photoacoustic-optoacoustic-thermoacoustic methods has allowed for addressing unmet biological and medical needs such as pre-clinical research, clinical imaging of vasculature, tissue and disease physiology, drug efficacy, surgery guidance, and therapy monitoring. Applications of this field encompass a wide range of medical imaging and sensing applications, including cancer, vascular diseases, brain neurophysiology, ophthalmology, and diabetes. Moreover, photoacoustics-optoacoustics-thermoacoustics is a multidisciplinary field, with contributions from chemistry and nanotechnology, where novel materials such as biodegradable nanoparticles, organic dyes, targeted agents, theranostic probes, and genetically expressed markers are being actively developed. These advanced materials have significantly improved the signal-to-noise ratio and tissue contrast in photoacoustic methods.
期刊最新文献
Bridging light and sound: A spironaphtopyran-rhodamine dyad with high-contrast photoswitching between fluorescence and photoacoustic signal Multi-parametric longitudinal imaging of cerebral biomarkers in a rodent model of Alzheimer’s disease A Ppb-level MIR-PAS for 12CO2/13CO2 isotope analysis toward on-line breath-based H. pylori sensing Ultrasound-guided sound speed correction for photoacoustic computed tomography Frequency domain laser ultrasound for inertial confinement fusion target wall thickness measurements
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1