Highly sensitive detection of Cr(VI), Pb(II) and Cd(II) ions by a new fluorescent sensor based on 4-amino-3-hydroxynaphthalene sulfonic acid-doped polypyrrole

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2020-10-14 DOI:10.20450/mjcce.2020.1978
M. L. Sall, A. Diaw, D. Gningue-Sall, M. Oturan, J. Aaron
{"title":"Highly sensitive detection of Cr(VI), Pb(II) and Cd(II) ions by a new fluorescent sensor based on 4-amino-3-hydroxynaphthalene sulfonic acid-doped polypyrrole","authors":"M. L. Sall, A. Diaw, D. Gningue-Sall, M. Oturan, J. Aaron","doi":"10.20450/mjcce.2020.1978","DOIUrl":null,"url":null,"abstract":"A new electrosynthesized, fluorescent 4-amino-3-hydroxynaphthalene-1-sulfonic acid-doped polypyrrole (AHNSA-PPy) was used for the detection of Cr(VI), Pb(II) and Cd(II) heavy metallic ions. The optical properties of AHNSA-PPy were studied by UV-VIS absorption and fluorescence spectrometry in diluted DMSO solutions. UV-VIS spectrum showed a main band at 260 nm, a moderate band at 240 nm, and shoulders at 285, 295, 320 and 360 nm, whereas the fluorescence spectrum presented an excitation peak at 330 nm and a main emission peak at 390 nm with a shoulder at 295 nm. The effects of heavy metallic ions, including Cr(VI), Pb(II), and Cd(II), on the AHNSA-PPy UV-VIS absorption and fluorescence spectra were investigated. AHNSA-PPy fluorescence spectra were strongly quenched upon increasing the Cr(VI), Pb(II) and Cd(II) concentrations. Linear Stern-Volmer relationships were established, and polynomial equations for Pb(II) and Cd(II) were obeyed, indicating the existence of a AHNSA-PPy dynamic fluorescence quenching mechanism for Cr(VI) and a combination of dynamic and static fluorescence quenching for Pb(II) and Cd(II). The AHNSA-PPy sensor showed high sensitivity for fluorescence detection of the three heavy metallic ions, with very low limits of detection (3σ) of 1.4 nM for Cr(VI), 2.7 nM for Cd(II) and 2.6 nM for Pb(II). Therefore, this very sensitive quenching fluorimetric sensor is proposed for the detection of trace, toxic heavy metallic ions in the environment.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2020-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.20450/mjcce.2020.1978","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 3

Abstract

A new electrosynthesized, fluorescent 4-amino-3-hydroxynaphthalene-1-sulfonic acid-doped polypyrrole (AHNSA-PPy) was used for the detection of Cr(VI), Pb(II) and Cd(II) heavy metallic ions. The optical properties of AHNSA-PPy were studied by UV-VIS absorption and fluorescence spectrometry in diluted DMSO solutions. UV-VIS spectrum showed a main band at 260 nm, a moderate band at 240 nm, and shoulders at 285, 295, 320 and 360 nm, whereas the fluorescence spectrum presented an excitation peak at 330 nm and a main emission peak at 390 nm with a shoulder at 295 nm. The effects of heavy metallic ions, including Cr(VI), Pb(II), and Cd(II), on the AHNSA-PPy UV-VIS absorption and fluorescence spectra were investigated. AHNSA-PPy fluorescence spectra were strongly quenched upon increasing the Cr(VI), Pb(II) and Cd(II) concentrations. Linear Stern-Volmer relationships were established, and polynomial equations for Pb(II) and Cd(II) were obeyed, indicating the existence of a AHNSA-PPy dynamic fluorescence quenching mechanism for Cr(VI) and a combination of dynamic and static fluorescence quenching for Pb(II) and Cd(II). The AHNSA-PPy sensor showed high sensitivity for fluorescence detection of the three heavy metallic ions, with very low limits of detection (3σ) of 1.4 nM for Cr(VI), 2.7 nM for Cd(II) and 2.6 nM for Pb(II). Therefore, this very sensitive quenching fluorimetric sensor is proposed for the detection of trace, toxic heavy metallic ions in the environment.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于4-氨基-3-羟基萘磺酸掺杂聚吡咯的新型荧光传感器对Cr(VI)、Pb(II)和Cd(II)离子的高灵敏度检测
一种新的电合成荧光4-氨基-3-羟基萘-1-磺酸掺杂聚吡咯(AHNSA-PPy)用于检测Cr(VI)、Pb(II)和Cd(II)重金属离子。采用紫外-可见光谱法和荧光光谱法研究了AHNSA-PPy在DMSO稀溶液中的光学性质。UV-VIS光谱在260nm处显示主带,在240nm处显示中等带,在285295320和360nm处显示肩峰,而荧光光谱在330nm处显示激发峰,在390nm处显示主发射峰,在295nm处显示肩峰。研究了重金属离子Cr(VI)、Pb(II)和Cd(II)对AHNSA PPy UV-VIS吸收和荧光光谱的影响。AHNSA-PPy荧光光谱随着Cr(VI)、Pb(II)和Cd(II)浓度的增加而强烈猝灭。建立了线性Stern-Volmer关系,Pb(II)和Cd(II)服从多项式方程,表明Cr(VI)存在AHNSA-PPy动态荧光猝灭机制,Pb(Ⅱ)和Cd(Ⅱ)存在动态和静态荧光猝灭的组合。AHNSA-PPy传感器对三种重金属离子的荧光检测显示出高灵敏度,Cr(VI)的检测限(3σ)非常低,为1.4nM,Cd(II)的检测极限为2.7nM,Pb(II)为2.6nM。因此,这种非常灵敏的猝灭荧光传感器被提出用于检测环境中的痕量、有毒重金属离子。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Intentions to move abroad among medical students: a cross-sectional study to investigate determinants and opinions. Analysis of Medical Rehabilitation Needs of 2023 Kahramanmaraş Earthquake Victims: Adıyaman Example. Efficacy of whole body vibration on fascicle length and joint angle in children with hemiplegic cerebral palsy. The change process questionnaire (CPQ): A psychometric validation. Prevalence and predictors of hand hygiene compliance in clinical, surgical and intensive care unit wards: results of a second cross-sectional study at the Umberto I teaching hospital of Rome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1