{"title":"Mechanical fault diagnosis of on‐load tap‐changer based on improved variational mode decomposition and relative density‐based outlier score","authors":"Hongrui Gu","doi":"10.1049/elp2.12354","DOIUrl":null,"url":null,"abstract":"In order to diagnose the mechanical fault of transformer on‐load tap‐changer (OLTC) effectively, a fault diagnosis method based on improved variational mode decomposition (VMD) and relative density‐based outlier score (RDOS) is proposed. Firstly, the signal is decomposed into a series of modal components with narrow band and distinguishing centre frequency by improved VMD based on optimal quality factor. Then, the energy, permutation entropy, power spectrum concentration degree and characteristic frequency of each modal component are calculated, and Laplacian‐score method is used to select the features with better discriminative ability. Finally, a RDOS is used to diagnose the mechanical fault of OLTC, and the mechanical condition is judged according to RDOS value. An experiment is conducted on the OLTC simulation experiment platform and the collected signals are processed. The result shows that the proposed method can diagnose mechanical fault effectively.","PeriodicalId":13352,"journal":{"name":"Iet Electric Power Applications","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-08-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Electric Power Applications","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1049/elp2.12354","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
In order to diagnose the mechanical fault of transformer on‐load tap‐changer (OLTC) effectively, a fault diagnosis method based on improved variational mode decomposition (VMD) and relative density‐based outlier score (RDOS) is proposed. Firstly, the signal is decomposed into a series of modal components with narrow band and distinguishing centre frequency by improved VMD based on optimal quality factor. Then, the energy, permutation entropy, power spectrum concentration degree and characteristic frequency of each modal component are calculated, and Laplacian‐score method is used to select the features with better discriminative ability. Finally, a RDOS is used to diagnose the mechanical fault of OLTC, and the mechanical condition is judged according to RDOS value. An experiment is conducted on the OLTC simulation experiment platform and the collected signals are processed. The result shows that the proposed method can diagnose mechanical fault effectively.
期刊介绍:
IET Electric Power Applications publishes papers of a high technical standard with a suitable balance of practice and theory. The scope covers a wide range of applications and apparatus in the power field. In addition to papers focussing on the design and development of electrical equipment, papers relying on analysis are also sought, provided that the arguments are conveyed succinctly and the conclusions are clear.
The scope of the journal includes the following:
The design and analysis of motors and generators of all sizes
Rotating electrical machines
Linear machines
Actuators
Power transformers
Railway traction machines and drives
Variable speed drives
Machines and drives for electrically powered vehicles
Industrial and non-industrial applications and processes
Current Special Issue. Call for papers:
Progress in Electric Machines, Power Converters and their Control for Wave Energy Generation - https://digital-library.theiet.org/files/IET_EPA_CFP_PEMPCCWEG.pdf