{"title":"Improvements of 210Po determination method in thermal water samples","authors":"Van- Hao Duong, Chau Nguyen Dinh, Trinh Phan Trong, Trung- Tien Chu","doi":"10.15625/2615-9783/16851","DOIUrl":null,"url":null,"abstract":"Determination of naturally radionuclides have been known well as an important topic in environmental study in recently. One of the most toxic radioisotope in nature, a daughter product of 238U decay chain is 210Po (polonium). The improvement and optimizations methods for determination of this attractive isotope are still presenting so far. In this paper, a new improved method was elaborated for 210Po determination in thermal water sample. In the proposed method, analytical optimization of spontaneous/auto deposition does not use Teflon cup, magnetic stirring or any preparing equipment/item only normal glass and a side of square silver. In addition, the optimization was neglected with absent of purification of polonium (Liquid-liquid extraction methods/Ion exchange chromatography/Extraction chromatographic separations). The outcome of optimal procedure were simplify, less time consuming, great reduction of costs with chemical recovery >80% and could apply for any liquid environmental samples.","PeriodicalId":23639,"journal":{"name":"VIETNAM JOURNAL OF EARTH SCIENCES","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"VIETNAM JOURNAL OF EARTH SCIENCES","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15625/2615-9783/16851","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"GEOSCIENCES, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 4
Abstract
Determination of naturally radionuclides have been known well as an important topic in environmental study in recently. One of the most toxic radioisotope in nature, a daughter product of 238U decay chain is 210Po (polonium). The improvement and optimizations methods for determination of this attractive isotope are still presenting so far. In this paper, a new improved method was elaborated for 210Po determination in thermal water sample. In the proposed method, analytical optimization of spontaneous/auto deposition does not use Teflon cup, magnetic stirring or any preparing equipment/item only normal glass and a side of square silver. In addition, the optimization was neglected with absent of purification of polonium (Liquid-liquid extraction methods/Ion exchange chromatography/Extraction chromatographic separations). The outcome of optimal procedure were simplify, less time consuming, great reduction of costs with chemical recovery >80% and could apply for any liquid environmental samples.