Simulating two Algerian cities' desalination plants coupled with solar energy systems using TRNSYS

IF 4.3 4区 环境科学与生态学 Q2 ENGINEERING, ENVIRONMENTAL Water Reuse Pub Date : 2023-08-22 DOI:10.2166/wrd.2023.141
Sara Irki, Edet Albright, N. Merzouk, S. Hanini, Sami Barkaoui, M. Benaissa, D. Ghernaout, N. Elboughdiri
{"title":"Simulating two Algerian cities' desalination plants coupled with solar energy systems using TRNSYS","authors":"Sara Irki, Edet Albright, N. Merzouk, S. Hanini, Sami Barkaoui, M. Benaissa, D. Ghernaout, N. Elboughdiri","doi":"10.2166/wrd.2023.141","DOIUrl":null,"url":null,"abstract":"\n \n The Bouzaréah in northern Algeria's province and Ghardaïa in southern Algeria's province are particularly vulnerable to drought and water scarcity, even if apparent differences in climatic conditions mark each region. Though it may seem counterintuitive, Ghardaïa has considerable water resources that could be tapped for agriculture. Our study aimed to design a prototype of a desalination unit coupled with a solar collector for these two provinces using the TRNSYS 16. The desalination unit is composed of vacuum membrane distillation (VMD) coupled with a solar collector, and the photovoltaic has been designed according to the climatic conditions of each region. In this work, the approach adopted is to integrate a model developed in the literature into a simulation environment (TRNSYS) coupled with the CODE-BLOCKS compiler and FORTRAN programming language to create a new component (i.e., VMD process). The permeation flux and the power to load reached their maximum values with the charge of solar irradiation 48 kg/h m2 and 6,300 kJ/h, respectively, for Ghardaïa at the sun irradiation value 800 W/m2 and temperature of 34 °C. Results showed that Ghardaïa had a higher GOR value than Bouzaréah over the year (10.947 vs. 8.3389).","PeriodicalId":34727,"journal":{"name":"Water Reuse","volume":" ","pages":""},"PeriodicalIF":4.3000,"publicationDate":"2023-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Water Reuse","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.2166/wrd.2023.141","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0

Abstract

The Bouzaréah in northern Algeria's province and Ghardaïa in southern Algeria's province are particularly vulnerable to drought and water scarcity, even if apparent differences in climatic conditions mark each region. Though it may seem counterintuitive, Ghardaïa has considerable water resources that could be tapped for agriculture. Our study aimed to design a prototype of a desalination unit coupled with a solar collector for these two provinces using the TRNSYS 16. The desalination unit is composed of vacuum membrane distillation (VMD) coupled with a solar collector, and the photovoltaic has been designed according to the climatic conditions of each region. In this work, the approach adopted is to integrate a model developed in the literature into a simulation environment (TRNSYS) coupled with the CODE-BLOCKS compiler and FORTRAN programming language to create a new component (i.e., VMD process). The permeation flux and the power to load reached their maximum values with the charge of solar irradiation 48 kg/h m2 and 6,300 kJ/h, respectively, for Ghardaïa at the sun irradiation value 800 W/m2 and temperature of 34 °C. Results showed that Ghardaïa had a higher GOR value than Bouzaréah over the year (10.947 vs. 8.3389).
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用TRNSYS模拟阿尔及利亚两个城市的海水淡化厂与太阳能系统的耦合
阿尔及利亚北部省的bouzarsamah和南部省的Ghardaïa尤其容易受到干旱和缺水的影响,尽管每个地区的气候条件明显不同。虽然看起来有悖常理,但Ghardaïa有相当多的水资源可以用于农业。我们的研究旨在使用TRNSYS 16为这两个省设计一个与太阳能集热器相结合的海水淡化装置的原型。海水淡化装置由真空膜蒸馏(VMD)和太阳能集热器组成,光伏根据各地的气候条件进行了设计。在这项工作中,采用的方法是将文献中开发的模型集成到仿真环境(TRNSYS)中,再加上CODE-BLOCKS编译器和FORTRAN编程语言,以创建一个新的组件(即VMD进程)。当太阳辐照量为800 W/m2,温度为34℃时,Ghardaïa的渗透通量和负荷功率分别为48 kg/h m2和6300 kJ/h时达到最大值。结果表明,Ghardaïa的GOR值高于bouzar (10.947 vs. 8.3389)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Water Reuse
Water Reuse Multiple-
CiteScore
6.20
自引率
8.90%
发文量
0
审稿时长
7 weeks
期刊最新文献
Removal of Tellurium(IV) from environmental aquatic systems using metal-organic framework material MIL-100(Fe) Effectiveness and health risk assessment of drinking water from different sources treated by local household water treatment methods in Bamenda, Cameroon Adsorption efficiency of biochar produced by aquaculture by-products for removing geosmin in aquaculture environment Enhancing stormwater treatment through ultrafiltration: impact of cleaning chemicals and backwash duration on membrane efficiency cutting-edge research on the action plan for the prevention and control of emerging contaminants in China
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1