Guido Alfaro Degan, Andrea Antonucci, Dario Lippiello
{"title":"Efficacy of Antivibration Gloves When Used with Electric Hammers of about 10 kg for Chiseling Limestone Rocks","authors":"Guido Alfaro Degan, Andrea Antonucci, Dario Lippiello","doi":"10.3390/safety9020027","DOIUrl":null,"url":null,"abstract":"The ISO Standard 10819:2013 defines the method for evaluating the performances of antivibration (AV) gloves, but when used in real fields, the protection can be dissimilar to that labeled. This paper investigates the transmissibility, at the palm level, of three different types of AV gloves (air, gel, neoprene) and an ordinary leather glove, during the use of four similar electric hammers (average weight of 10 kg, and average impact energy of 18 J), in a limestone quarry plant. As the average triaxial transmissibility for all the hammers, results show very limited benefits in reducing the vibration (6%), with no significative differences among the different gloves. The working leather glove, instead, shows a transmissibility quite equal to the unit. Anyway, results can be different for the same glove when used among the different hammers, providing in some cases 19% of protection. Some differences can be found regarding the transmissibility through the three main axes for the same type of glove: the glove in gel seems to perform better in shear than in compression. The transmissibility in compression is around 20% higher than that provided by the manufacturers of the certified gloves. The usage of specific excitation curves during laboratory tests could help in providing a more accurate estimation of the transmissibility of the gloves when used with a specific tool.","PeriodicalId":36827,"journal":{"name":"Safety","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2023-04-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/safety9020027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0
Abstract
The ISO Standard 10819:2013 defines the method for evaluating the performances of antivibration (AV) gloves, but when used in real fields, the protection can be dissimilar to that labeled. This paper investigates the transmissibility, at the palm level, of three different types of AV gloves (air, gel, neoprene) and an ordinary leather glove, during the use of four similar electric hammers (average weight of 10 kg, and average impact energy of 18 J), in a limestone quarry plant. As the average triaxial transmissibility for all the hammers, results show very limited benefits in reducing the vibration (6%), with no significative differences among the different gloves. The working leather glove, instead, shows a transmissibility quite equal to the unit. Anyway, results can be different for the same glove when used among the different hammers, providing in some cases 19% of protection. Some differences can be found regarding the transmissibility through the three main axes for the same type of glove: the glove in gel seems to perform better in shear than in compression. The transmissibility in compression is around 20% higher than that provided by the manufacturers of the certified gloves. The usage of specific excitation curves during laboratory tests could help in providing a more accurate estimation of the transmissibility of the gloves when used with a specific tool.