CONTACT POINTS DISTRIBUTION ACCORDING TO THE ARTICULATOR TYPE: SEMIADJUSTABLE VERSUS NON ADAPTABLE VERSUS DIGITAL

Q4 Dentistry Revista Romana de Stomatologie Pub Date : 2021-06-30 DOI:10.37897/rjs.2021.2.9
O. Almășan, Cluj-Napoca România Universitatea de Medicină și Farmacie „Iuliu Hație, S. Buduru, S. Iacob, Andreea Chisnoiu, Loredana Miţaru, Mihai Miţaru, Maria Dămășaru, Irina Grecu Mareşal, M. Negucioiu, Sibiu România Universitatea de Medicină și Farmacie „Lucian Blag, Umfst „G.E. Palade“ Tg Mureş România Ortodonţie, St. Gallen Germania Ortodonţie şi Ortopedie dento-facială
{"title":"CONTACT POINTS DISTRIBUTION ACCORDING TO THE ARTICULATOR TYPE: SEMIADJUSTABLE VERSUS NON ADAPTABLE VERSUS DIGITAL","authors":"O. Almășan, Cluj-Napoca România Universitatea de Medicină și Farmacie „Iuliu Hație, S. Buduru, S. Iacob, Andreea Chisnoiu, Loredana Miţaru, Mihai Miţaru, Maria Dămășaru, Irina Grecu Mareşal, M. Negucioiu, Sibiu România Universitatea de Medicină și Farmacie „Lucian Blag, Umfst „G.E. Palade“ Tg Mureş România Ortodonţie, St. Gallen Germania Ortodonţie şi Ortopedie dento-facială","doi":"10.37897/rjs.2021.2.9","DOIUrl":null,"url":null,"abstract":"Objectives. To analyze the location and intensity of occlusal contact points using three types of articulators: non adjustable, semiadjustable and digital with aiming at improving the diagnostic and treatment options in dental medicine. Material and method. For analyzing the distribution of contact points, the casts of a patient were mounted in the non adjustable and semiadjustable articulator. Intraoral scanning was performed using an intraoral scanner (Trios 3Shape) and reviewed in a virtual articulator. Occlusion obtained by the three methods was compared to the clinical situation. Results. Contact points in maximum intercuspation, propulsion and lateral movements were analyzed. The points obtained by using the non adjustable articulator have been less intense and more unprecise. By digitizing the contact points, the image becomes more accurate and sharp. Discussion. The semiadjustable articulator reproduces the contact points which are consistent with the clinical situation. Major differences occur when using the non adjustable articulator, which has a limited capacity of reproducing the clinical movements, therefore the marks are non consistent with the real clinical situation. The digital articulator seems promising in terms of eccentric movements. Conclusions. However performing an articulator may be, the clinical maximum intercuspation will never be fittingly reproduced, due to the fact that articulators are rigid systems, whereas the oral cavity has an elasticity, resulting from the mandible, teeth and periodontal ligaments. Virtual articulators need to be further developed for more accurate results.","PeriodicalId":33514,"journal":{"name":"Revista Romana de Stomatologie","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Romana de Stomatologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37897/rjs.2021.2.9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 1

Abstract

Objectives. To analyze the location and intensity of occlusal contact points using three types of articulators: non adjustable, semiadjustable and digital with aiming at improving the diagnostic and treatment options in dental medicine. Material and method. For analyzing the distribution of contact points, the casts of a patient were mounted in the non adjustable and semiadjustable articulator. Intraoral scanning was performed using an intraoral scanner (Trios 3Shape) and reviewed in a virtual articulator. Occlusion obtained by the three methods was compared to the clinical situation. Results. Contact points in maximum intercuspation, propulsion and lateral movements were analyzed. The points obtained by using the non adjustable articulator have been less intense and more unprecise. By digitizing the contact points, the image becomes more accurate and sharp. Discussion. The semiadjustable articulator reproduces the contact points which are consistent with the clinical situation. Major differences occur when using the non adjustable articulator, which has a limited capacity of reproducing the clinical movements, therefore the marks are non consistent with the real clinical situation. The digital articulator seems promising in terms of eccentric movements. Conclusions. However performing an articulator may be, the clinical maximum intercuspation will never be fittingly reproduced, due to the fact that articulators are rigid systems, whereas the oral cavity has an elasticity, resulting from the mandible, teeth and periodontal ligaments. Virtual articulators need to be further developed for more accurate results.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
根据咬合架类型的接触点分布:半可调节与不可调节与数字
目标。目的分析非可调、半可调和数字式三种咬合器的咬合接触点位置和强度,以提高口腔医学的诊断和治疗选择。材料和方法。为了分析接触点的分布,将患者的模型安装在不可调节和半可调节的关节器中。使用口内扫描仪(Trios 3Shape)进行口内扫描,并在虚拟发音器中进行检查。将三种方法获得的咬合情况与临床情况进行比较。结果。分析了最大间隔、推进和横向运动中的接触点。使用不可调节的铰接器获得的点强度较低,精度较低。通过数字化的接触点,图像变得更加准确和清晰。讨论。半可调关节器再现了与临床情况一致的接触点。使用不可调节的关节器时产生较大的差异,其复制临床运动的能力有限,因此标记与临床真实情况不一致。数字发音器在古怪动作方面似乎很有前途。结论。无论如何使用关节器,临床最大的内嵌都无法恰当地再现,因为关节器是刚性系统,而口腔具有弹性,这是由下颌骨、牙齿和牙周韧带造成的。为了获得更准确的结果,需要进一步开发虚拟发音器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.10
自引率
0.00%
发文量
21
审稿时长
4 weeks
期刊最新文献
SEM and EDS comparative studies about the homogeneity of some cements used for luting of posts Ultrastructural studies on implants failure with immediate or late loading The causes of adhesive direct dental restorations failures A systematic review of sinus floor augmentation complications. Does graft type influence the complications rate? The RT-PCR additional value in detecting periodontal pathogens in periodontitis patients
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1