{"title":"Identifying the factors influencing the voltage quality of 6kV grids when using electric excavators in surface mining","authors":"L. X. Thanh, H. Bun","doi":"10.33271/mining16.02.073","DOIUrl":null,"url":null,"abstract":"Purpose. The research purpose is to study the relationship between the number of electric excavators and their impact on reducing the voltage losses. As a result of the research, it becomes possible to obtain factors that can help the manager to correctly understand the effect of power compensation caused by the over-excitation mode of electric excavators. Methods. The paper uses the Jacobian matrix transformation to simulate the power flows of electric excavators, the driving mechanisms of which are mainly synchronous motors. The input data for the simulation is the in-situ measurement data representing the inverse power flow. A diagram and a software to determine the factors corresponding to the number of electric excavators are also provided. Findings. A cross-reference table has been compiled showing the ratio of factors corresponding to the number of electric excavators in a 6kV grid. An appropriate software has also been developed, including a table for correcting typical equations for calculating voltage losses. Originality. The proposed factor is conditioned by over-excitation mode of excavators operating as compensation machines in a 6kV grid. Practical implications. When calculating the voltage loss in a 6kV grid of surface mines, if the design feeder contains electric excavators, a modified factor should be added to give a correct idea of the voltage quality.","PeriodicalId":43896,"journal":{"name":"Mining of Mineral Deposits","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mining of Mineral Deposits","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33271/mining16.02.073","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MINING & MINERAL PROCESSING","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose. The research purpose is to study the relationship between the number of electric excavators and their impact on reducing the voltage losses. As a result of the research, it becomes possible to obtain factors that can help the manager to correctly understand the effect of power compensation caused by the over-excitation mode of electric excavators. Methods. The paper uses the Jacobian matrix transformation to simulate the power flows of electric excavators, the driving mechanisms of which are mainly synchronous motors. The input data for the simulation is the in-situ measurement data representing the inverse power flow. A diagram and a software to determine the factors corresponding to the number of electric excavators are also provided. Findings. A cross-reference table has been compiled showing the ratio of factors corresponding to the number of electric excavators in a 6kV grid. An appropriate software has also been developed, including a table for correcting typical equations for calculating voltage losses. Originality. The proposed factor is conditioned by over-excitation mode of excavators operating as compensation machines in a 6kV grid. Practical implications. When calculating the voltage loss in a 6kV grid of surface mines, if the design feeder contains electric excavators, a modified factor should be added to give a correct idea of the voltage quality.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
露天开采中使用电动挖掘机时影响6kV电网电压质量的因素识别
目的。研究目的是研究电动挖掘机数量与其对降低电压损失的影响之间的关系。通过研究,可以获得有助于管理人员正确理解电动挖掘机过激励方式造成的功率补偿效果的因素。方法。本文采用雅可比矩阵变换对以同步电动机为主要驱动机构的电动挖掘机的动力流进行了仿真。模拟的输入数据是代表反向潮流的现场测量数据。还提供了确定电动挖掘机数量对应因素的示意图和软件。发现。编制了一个交叉参考表,显示了6kV电网中电动挖掘机数量对应的因素比率。还开发了一个适当的软件,包括一个用于修正计算电压损失的典型方程的表。创意。所提出的因素是由挖掘机作为补偿机在6kV电网中运行的过励磁模式所决定的。实际意义。在计算露天矿6kV电网电压损失时,如果设计馈线中含有电动挖掘机,则应加入修正因子,以正确理解电压质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Mining of Mineral Deposits
Mining of Mineral Deposits MINING & MINERAL PROCESSING-
CiteScore
5.20
自引率
15.80%
发文量
52
期刊最新文献
Analyzing stability of protective structures as the elements of geotechnical tailing pond safety Mining of non-metallic mineral deposits in the context of Ukraine’s reconstruction in the war and post-war periods Optimizing the blast fragmentation quality of discontinuous rock mass: Case study of Jebel Bouzegza Open-Cast Mine, North Algeria Use of solid mining waste to improve water retention capacity of loamy soils Deformation as a process to transform shape and volume of protective structures of the development mine workings during coal-rock mass off-loading
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1