Multi-modified epoxy insulation with improved flashover threshold for HVDC applications

IF 3.8 Q2 ENGINEERING, ELECTRICAL & ELECTRONIC IET Nanodielectrics Pub Date : 2023-07-04 DOI:10.1049/nde2.12058
Inzamam Ul Haq, Feipeng Wang
{"title":"Multi-modified epoxy insulation with improved flashover threshold for HVDC applications","authors":"Inzamam Ul Haq,&nbsp;Feipeng Wang","doi":"10.1049/nde2.12058","DOIUrl":null,"url":null,"abstract":"<p>The flashover threshold (<i>V</i><sub><i>flsh</i></sub>) of polymer insulations such as epoxy (EP) in HVDC systems can be augmented by modifying their surface with an appropriate treatment technology. For such purpose, several surface treatment methods such as ion beam, sandpaper and a combination of the two is introduced. Firstly, insulation samples with pure epoxy (<i>EP</i><sub><i>pure</i></sub>), different ion beam treatment periods (<i>EP</i><sub><i>ion</i></sub>;10, 15, 20 min) and different roughness (<i>EP</i><sub><i>sand</i></sub>; <i>R</i>1 = 4.23 μm, <i>R</i>2 = 6.34 μm, <i>R</i>3 = 9.21 μm) are prepared on the laboratory scale. Afterward, based on several characterisations, such as surface conductivity, mean surface roughness and potential distribution of these insulations, multi-modified insulation (<i>EP</i><sub><i>multi</i></sub> = <i>EP</i><sub><i>ion-20</i></sub> + <i>EP</i><sub><i>sand-R3</i></sub>) is prepared. In the end, the <i>V</i><sub><i>flsh</i></sub> of each insulation group is measured and compared to examine the effectiveness of the proposed modifications. It is obtained that the <i>V</i><sub><i>flsh</i></sub> of the modified insulations augmented dramatically irrespective of the treatment method. The <i>V</i><sub><i>flsh</i></sub> of the insulation group <i>EP</i><sub><i>multi</i></sub> augmented by 52.66 % which is the highest improvement among all insulation groups. In short, the proposed surface modifications are effective and could be used as references to enhance the insulation strength of polymer dielectrics in HVDC systems.</p>","PeriodicalId":36855,"journal":{"name":"IET Nanodielectrics","volume":"6 4","pages":"267-275"},"PeriodicalIF":3.8000,"publicationDate":"2023-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ietresearch.onlinelibrary.wiley.com/doi/epdf/10.1049/nde2.12058","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IET Nanodielectrics","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/nde2.12058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

The flashover threshold (Vflsh) of polymer insulations such as epoxy (EP) in HVDC systems can be augmented by modifying their surface with an appropriate treatment technology. For such purpose, several surface treatment methods such as ion beam, sandpaper and a combination of the two is introduced. Firstly, insulation samples with pure epoxy (EPpure), different ion beam treatment periods (EPion;10, 15, 20 min) and different roughness (EPsand; R1 = 4.23 μm, R2 = 6.34 μm, R3 = 9.21 μm) are prepared on the laboratory scale. Afterward, based on several characterisations, such as surface conductivity, mean surface roughness and potential distribution of these insulations, multi-modified insulation (EPmulti = EPion-20 + EPsand-R3) is prepared. In the end, the Vflsh of each insulation group is measured and compared to examine the effectiveness of the proposed modifications. It is obtained that the Vflsh of the modified insulations augmented dramatically irrespective of the treatment method. The Vflsh of the insulation group EPmulti augmented by 52.66 % which is the highest improvement among all insulation groups. In short, the proposed surface modifications are effective and could be used as references to enhance the insulation strength of polymer dielectrics in HVDC systems.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
多改性环氧绝缘与改进的HVDC应用的闪络阈值
高压直流系统中环氧树脂(EP)等聚合物绝缘体的闪络阈值(Vflsh)可以通过适当的处理技术修饰其表面来提高。为此,介绍了离子束、砂纸及两者结合的几种表面处理方法。首先,采用纯环氧树脂(EPpure)、不同离子束处理时间(EPion;10、15、20 min)和不同粗糙度(EPsand;R1 = 4.23 μm, R2 = 6.34 μm, R3 = 9.21 μm)在实验室尺度上制备。然后,根据这些绝缘体的表面电导率、平均表面粗糙度和电位分布等几个特征,制备了多重改性绝缘体(EPmulti = epon -20 + EPsand-R3)。最后,测量和比较每个绝缘组的Vflsh,以检查所提出的修改的有效性。结果表明,无论采用何种处理方法,改性后的绝缘材料的Vflsh均显著增大。保温组EPmulti的Vflsh提高了52.66%,是所有保温组中提高幅度最大的。总之,所提出的表面改性是有效的,可以为提高高压直流系统中聚合物介电体的绝缘强度提供参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
IET Nanodielectrics
IET Nanodielectrics Materials Science-Materials Chemistry
CiteScore
5.60
自引率
3.70%
发文量
7
审稿时长
21 weeks
期刊最新文献
A combined technique for power transformer fault diagnosis based on k-means clustering and support vector machine Improvement in non-linear electrical conductivity of silicone rubber by incorporating zinc oxide fillers and grafting small polar molecules Traditional fault diagnosis methods for mineral oil-immersed power transformer based on dissolved gas analysis: Past, present and future Enhanced thermal conductivity and self-healing property of PUDA/boron nitride micro-sheets composites with a small number of graphene nano-platelets Improving the dielectric properties of polypropylene for metallised film capacitors based on cyclic olefin copolymer blending
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1