Variation in the CFF with Glycaemic Control in Type 2 Diabetes Mellitus PatientsVariation in the CFF with Glycaemic Control in Type 2 Diabetes Mellitus Patients
{"title":"Variation in the CFF with Glycaemic Control in Type 2 Diabetes Mellitus PatientsVariation in the CFF with Glycaemic Control in Type 2 Diabetes Mellitus Patients","authors":"G. Kumar, K. Rekha, B. Jamuna, Prem Jayarajan","doi":"10.37506/IJOP.V8I2.1243","DOIUrl":null,"url":null,"abstract":"Introduction: India has a large number of diabetic patients and there is a steep rise in the incidence ofdiabetes in the last decade. Diabetic control is categorized as poor control (HbA1c levels above 7%) andgood control (HbA1c levels below 7%). Critical flicker fusion frequency (CFF) is a non-invasive test, whichcould help early detection of retinal dysfunction and optic neuropathic changes in Type 2 diabetes mellitus(T2DM).Objective: To compare the CFF betweenGroup 1: T2DM (HbA1c 7%).Methodology: Sixty diagnosed T2DM patients were the subjects in this study. Thirty patients had theirHbA1c 7 g%. The patients were recruited from Medicine department, Rajarajeswari MedicalCollege and Hospital. CFF was measured using an in-house built apparatus. CFF values were noted and thenanalyzed.Results and Discussion: The mean CFF in group I and the group II patients were 30.17+ 4.69 Hz and26.32+ 6.70 Hz, respectively. This was highly significant (P = 0.012). The significantly lower CFF in thepoorly controlled group II diabetics can be attributed to poorglycemic control in that group.","PeriodicalId":92916,"journal":{"name":"International journal of physiology","volume":" ","pages":"57-61"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of physiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37506/IJOP.V8I2.1243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: India has a large number of diabetic patients and there is a steep rise in the incidence ofdiabetes in the last decade. Diabetic control is categorized as poor control (HbA1c levels above 7%) andgood control (HbA1c levels below 7%). Critical flicker fusion frequency (CFF) is a non-invasive test, whichcould help early detection of retinal dysfunction and optic neuropathic changes in Type 2 diabetes mellitus(T2DM).Objective: To compare the CFF betweenGroup 1: T2DM (HbA1c 7%).Methodology: Sixty diagnosed T2DM patients were the subjects in this study. Thirty patients had theirHbA1c 7 g%. The patients were recruited from Medicine department, Rajarajeswari MedicalCollege and Hospital. CFF was measured using an in-house built apparatus. CFF values were noted and thenanalyzed.Results and Discussion: The mean CFF in group I and the group II patients were 30.17+ 4.69 Hz and26.32+ 6.70 Hz, respectively. This was highly significant (P = 0.012). The significantly lower CFF in thepoorly controlled group II diabetics can be attributed to poorglycemic control in that group.