{"title":"Analisis Eksergi Pada Pembangkit Listrik yang Memanfaatkan Panas Buangan Di PT Semen Padang","authors":"Nadry Heroza, Adjar Pratoto","doi":"10.14710/teknik.v43i2.37333","DOIUrl":null,"url":null,"abstract":"[Title: Exergy Analysis of Waste Heat Recovery Power Generation system at PT Semen Padang] Exergy analysis of a power plant that utilizes exhaust heat at PT. Semen Padang was carried out to identify the reliability of the power generating system and its main components that could be used as a basis for optimizing the utilization of exhaust heat and optimizing the operation of the generator to make it more efficient with increasing usage life. The exergy flow and efficiency are calculated for each component which is then used to calculate the exergy destroyed in the respective component. Calculations are also carried out on the system at the time of commissioning in order to get how much the exergy efficiency has changed since the system was operational. The components of this plant include SP boiler, AQC boiler, turbine, condenser, condensate pump, flasher, boiler feed pump, and economizer. AQC boiler is the component with the highest exergy value that is destroyed, which is 4405.34 kW or 32.98% of the total exergy destroyed in the system. In comparison, the condensate pump is the component that has the smallest destroyed exergy value of 18.94 kW (0.14%). The system efficiency in January 2012 was 62.60% and decreased in December 2019 to 53.04%, where the overall system exergy efficiency decreased by 9.56% within 7 years of operation..","PeriodicalId":30795,"journal":{"name":"Teknik","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Teknik","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14710/teknik.v43i2.37333","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
[Title: Exergy Analysis of Waste Heat Recovery Power Generation system at PT Semen Padang] Exergy analysis of a power plant that utilizes exhaust heat at PT. Semen Padang was carried out to identify the reliability of the power generating system and its main components that could be used as a basis for optimizing the utilization of exhaust heat and optimizing the operation of the generator to make it more efficient with increasing usage life. The exergy flow and efficiency are calculated for each component which is then used to calculate the exergy destroyed in the respective component. Calculations are also carried out on the system at the time of commissioning in order to get how much the exergy efficiency has changed since the system was operational. The components of this plant include SP boiler, AQC boiler, turbine, condenser, condensate pump, flasher, boiler feed pump, and economizer. AQC boiler is the component with the highest exergy value that is destroyed, which is 4405.34 kW or 32.98% of the total exergy destroyed in the system. In comparison, the condensate pump is the component that has the smallest destroyed exergy value of 18.94 kW (0.14%). The system efficiency in January 2012 was 62.60% and decreased in December 2019 to 53.04%, where the overall system exergy efficiency decreased by 9.56% within 7 years of operation..